Metabolomics-on-a-Chip of Hepatotoxicity Induced by Anticancer Drug Flutamide and Its Active Metabolite Hydroxyflutamide Using HepG2/C3a Microfluidic Biochips
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We used the recently introduced "metabolomics-on-a-chip" approach to test secondary drug toxicity in bioartificial organs. Bioartificial organs cultivated in microfluidic culture conditions provide a beneficial environment, in which the cellular cytoprotective mechanisms are enhanced, compared with Petri dish culture conditions. We investigated the metabolic response of HepG2/C3a cells exposed to flutamide, an anticancer prodrug, and hydroxyflutamide (HF), its active metabolite, in a microfluidic biochip. The cellular response was analyzed by (1)H nuclear magnetic resonance spectroscopy to identify cell-specific molecule-response markers. The metabolic response to flutamide results in a disruption of glucose homeostasis and in mitochondrial dysfunctions. This flutamide-specific metabolic response was illustrated by a reduction of the extracellular glucose and fructose consumptions and a general reduction of the tricarboxylic acid cycle activity leading to the reduction of the consumption of several amino acids. We also found a higher production of 3-hydroxybutyrate and lactate, and the reduction of the albumin production compared with controls. The toxic metabolic signature associated with the active metabolite HF was illustrated by a high-energy demand and an increase in several amino acid metabolism. Finally, for both molecules, the hepatotoxicity was correlated to the glutathione (GSH) metabolism illustrated by the levels of the 2-hydroxybutyrate and pyroglutamate productions and the increase of the glutamate and glycine productions. Thus, the entire set of results contributed to extract specific mechanistic toxic signatures and their relation to hepatotoxicity, which appeared consistent with literature reports. As new finding of HepG2/C3a cells hepatotoxicity, we propose a metabolic network with a related list of metabolite variations to describe the GSH depletion when followed by a cell death for the HepG2/C3a cells cultivated in our polydimethylsiloxane microfluidic biochips. Our findings illustrate the potential of metabolomics-on-a-chip as an in vitro alternative method for predictive toxicology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional behavior of primary rat liver cells in a three-dimensional perfused microarray bioreactor
Powers, M. J., Janigian, D. M., Wack, K. E., Baker, C. S., Stolz, D. B., & Griffith, L. G. (2002) · Tissue Engineering · doi:10.1089/107632702760184745 · Cited by 234
Cited by
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Application of microfluidic chip technology in pharmaceutical analysis: A review
Cui, P., & Wang, S. (2019) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2018.12.001 · Cited by 390
Marx, U. (2016) · ALTEX · doi:10.14573/altex.1603161 · Cited by 295
“…described above, MPS-based single-organ liver modeling has led to a large variety of liver-on-achip devices (Baudoin et al., 2014a; Hwa et al., 2007; Kane et al., 2006; Khetani and Bhatia, 2008; Leclerc et al., 2014, 2015; Legendre et al., 2013, 2014; Pasirayi et al., 2014; Snouber et al., 2013).”
Beckwitt, C. H., Clark, A. M., Wheeler, S., Taylor, D. L., Stolz, D. B., Griffith, L., & Wells, A. (2018) · Experimental Cell Research · doi:10.1016/j.yexcr.2017.12.023 · Cited by 208
Metadata
- Authors
- Choucha Snouber, L., Bunescu, A., Naudot, M., Legallais, C., Brochot, C., Dumas, M. E., Elena-Herrmann, B., & Leclerc, E.
- Venue
- Toxicological Sciences
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-07-27
- Volume
- 132
- Issue
- 1
- Pages
- 8-20
- ISSN
- 1096-0929 (ISSN-L)
- 1096-6080
- OpenAlex
- W2136863166
- Cited by
- 98
- References
- 1
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.