The DOI matches its Crossref record; 99 of the 99 references it cites were found in a registry or an index.
Application of microfluidic chip technology in pharmaceutical analysis: A review
Open accessAbstract
The development of pharmaceutical analytical methods represents one of the most significant aspects of drug development. Recent advances in microfabrication and microfluidics could provide new approaches for drug analysis, including drug screening, active testing and the study of metabolism. Microfluidic chip technologies, such as lab-on-a-chip technology, three-dimensional (3D) cell culture, organs-on-chip and droplet techniques, have all been developed rapidly. Microfluidic chips coupled with various kinds of detection techniques are suitable for the high-throughput screening, detection and mechanistic study of drugs. This review highlights the latest (2010-2018) microfluidic technology for drug analysis and discusses the potential future development in this field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Hydrogels in controlled release formulations: Network design and mathematical modeling
Lin, C.-C., & Metters, A. T. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.004 · Cited by 1,768
The past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203
Schneider, G. (2018) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2017.232 · Cited by 910 · cited 1×
“speed by hundreds of times and can decrease costs [3].”
BackgroundZhang, Y. S., Aleman, J., Shin, S. R., Kilic, T., Kim, D., Mousavi Shaegh, S. A., Massa, S., Riahi, R., Chae, S., Hu, N., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1612906114 · Cited by 833
Emerging Technologies for Next-Generation Point-of-Care Testing
Vashist, S. K., Luppa, P. B., Yeo, L. Y., Ozcan, A., & Luong, J. H. T. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.001 · Cited by 705
Three-dimensional tissue culture based on magnetic cell levitation
Souza, G. R., Molina, J. R., Raphael, R. M., Ozawa, M. G., Stark, D. J., Levin, C. S., Bronk, L. F., Ananta, J. S., Mandelin, J., Georgescu, M.-M., et al. (2010) · Nature Nanotechnology · doi:10.1038/nnano.2010.23 · Cited by 662
Fundamentals of microfluidic cell culture in controlled microenvironments
Young, E. W. K., & Beebe, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b909900j · Cited by 615
Wang, Y. I., Abaci, H. E., & Shuler, M. L. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26045 · Cited by 563
Paper‐Based Inkjet‐Printed Microfluidic Analytical Devices
Yamada, K., Henares, T. G., Suzuki, K., & Citterio, D. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411508 · Cited by 501
Cited by
Artificial Intelligence in Pharmaceutical Technology and Drug Delivery Design
Vora, L. K., Gholap, A. D., Jetha, K., Thakur, R. R. S., Solanki, H. K., & Chavda, V. P. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15071916 · Cited by 1,061
Challenges of applying multicellular tumor spheroids in preclinical phase
Han, S. J., Kwon, S., & Kim, K. S. (2021) · Cancer Cell International · doi:10.1186/s12935-021-01853-8 · Cited by 428
Pattanayak, P., Singh, S. K., Gulati, M., Vishwas, S., Kapoor, B., Chellappan, D. K., Anand, K., Gupta, G., Jha, N. K., Gupta, P. K., et al. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-021-02502-2 · Cited by 330
Investigation of human trophoblast invasion in vitro
Abbas, Y., Turco, M. Y., Burton, G. J., & Moffett, A. (2020) · Human Reproduction Update · doi:10.1093/humupd/dmaa017 · Cited by 318
Zhou, Y., Shen, J. X., & Lauschke, V. M. (2019) · Frontiers in Pharmacology · doi:10.3389/fphar.2019.01093 · Cited by 85
Metadata
- Authors
- Cui, P., & Wang, S.
- Venue
- Journal of Pharmaceutical Analysis
- Publisher
- Elsevier BV
- Published
- 2019-08
- Volume
- 9
- Issue
- 4
- Pages
- 238-247
- ISSN
- 2095-1779 (ISSN-L)
- OpenAlex
- W2903726465
- Cited by
- 390
- References
- 99
- FWCI
- 10.10
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of microfluidic chip technology in pharmaceutical analysis: A review. https://app.cochat.ai/papers/10.1016/j.jpha.2018.12.001
- The paper
- Cui, P., & Wang, S. (2019). Application of microfluidic chip technology in pharmaceutical analysis: A review. Journal of Pharmaceutical Analysis. https://doi.org/10.1016/j.jpha.2018.12.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.