Refining the Human iPSC-Cardiomyocyte Arrhythmic Risk Assessment Model
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Human induced pluripotent stem cell-derived cardiomyocytes (hiPS-CMs) are capable of detecting drug-induced clinical arrhythmia, Torsade de Pointes (TdP), and QT prolongation. Efforts herein employ a broad set of structurally diverse drugs to optimize the predictive algorithm for applications in discovery toxicology and cardiac safety screening. The changes in the beat rhythm and rate of a confluent monolayer of hiPS-CMs by 88 marketed and 30 internal discovery compounds were detected with real-time cellular impedance measurement and quantified by measures of arrhythmic beating (IB20, lowest concentration inducing ≥ 20% arrhythmic [irregular, atypical] beats in 3 consecutive 20-s sweeps, and predicted proarrhythmic score [PPS]-IB20) or changes in beat rate (BR20, the lowest concentration inducing a reduction in beat rate of ≥ 20% at 3 consecutive sweeps compared with the time-matched vehicle control group, and PPS-BR20). Drug-induced arrhythmic beats and reductions in beat rates are predictive of clinical arrhythmia and QT prolongation, respectively. A threshold of ≤ 10 μM for class determination results in 82% in vitro-in vivo concordance for TdP prediction and 91% sensitivity for non-TdP arrhythmia detection, or 83% and 91% if clinically efficacious plasma (effective serum therapeutic concentration [C eff]) values are incorporated. This human cardiomyocyte arrhythmic risk (hCAR) model provides greater predictivity for torsadogenicity in humans compared with either human ether-a-go-go-related gene (hERG) inhibition (75%) or QT prolongation (81%). The concordance of beat rate reductions to predict clinical QT prolongation is 86%, or 87% when C eff is considered, which is greater than a hERG signal (80%). Further, arrhythmic beats resulting from cytotoxicity were identified by a distinct arrhythmic beating pattern, which occurred after the onset of cytolethality. This hCAR assay showed increased performance over existing preclinical tools in predicting clinical QT prolongation, arrhythmia, and TdP. Thus, hiPS-CMs are a relevant cell system to improve evaluating cardiac safety liabilities of drug candidates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O’Brien, P. J., Irwin, W., Diaz, D., Howard-Cofield, E., Krejsa, C. M., Slaughter, M. R., Gao, B., Kaludercic, N., Angeline, A., Bernardi, P., et al. (2006) · Archives of Toxicology · doi:10.1007/s00204-006-0091-3 · Cited by 609
Laverty, H., Benson, C., Cartwright, E., Cross, M., Garland, C., Hammond, T., Holloway, C., McMahon, N., Milligan, J., Park, B., et al. (2011) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2011.01255.x · Cited by 363
hERG channel trafficking: Novel targets in drug-induced long QT syndrome
Dennis, A., Wang, L., Wan, X., & Ficker, E. (2007) · Biochemical Society Transactions · doi:10.1042/bst0351060 · Cited by 134
Cited by
Evolution of strategies to improve preclinical cardiac safety testing
Gintant, G., Sager, P. T., & Stockbridge, N. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2015.34 · Cited by 407
Human Engineered Heart Tissue: Analysis of Contractile Force
Mannhardt, I., Breckwoldt, K., Letuffe-Brenière, D., Schaaf, S., Schulz, H., Neuber, C., Benzin, A., Werner, T., Eder, A., Schulze, T., et al. (2016) · Stem Cell Reports · doi:10.1016/j.stemcr.2016.04.011 · Cited by 398
Induced Pluripotent Stem Cells and Their Use in Human Models of Disease and Development
Karagiannis, P., Takahashi, K., Saito, M., Yoshida, Y., Okita, K., Watanabe, A., Inoue, H., Yamashita, J. K., Todani, M., Nakagawa, M., et al. (2019) · Physiological Reviews · doi:10.1152/physrev.00039.2017 · Cited by 368
Blinova, K., Stohlman, J., Vicente, J., Chan, D., Johannesen, L., Hortigon-Vinagre, M. P., Zamora, V., Smith, G., Crumb, W. J., Pang, L., et al. (2017) · Toxicological Sciences · doi:10.1093/toxsci/kfw200 · Cited by 272
Induced pluripotent stem cells: at the heart of cardiovascular precision medicine
Chen, I. Y., Matsa, E., & Wu, J. C. (2016) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2016.36 · Cited by 191
Metadata
- Authors
- Guo, L., Coyle, L., Abrams, R. M. C., Kemper, R., Chiao, E. T., & Kolaja, K. L.
- Venue
- Toxicological Sciences
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-09-18
- Volume
- 136
- Issue
- 2
- Pages
- 581-594
- ISSN
- 1096-0929 (ISSN-L)
- 1096-6080
- OpenAlex
- W2133124132
- Cited by
- 145
- References
- 3
- FWCI
- 11.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Refining the Human iPSC-Cardiomyocyte Arrhythmic Risk Assessment Model. https://app.cochat.ai/papers/10.1093/toxsci/kft205
- The paper
- Guo, L., Coyle, L., Abrams, R. M. C., Kemper, R., Chiao, E. T., & Kolaja, K. L. (2013). Refining the Human iPSC-Cardiomyocyte Arrhythmic Risk Assessment Model. Toxicological Sciences. https://doi.org/10.1093/toxsci/kft205
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.