Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 197

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A comparison of strain and fluid shear stress in stimulating bone cell responses—a computational and experimental study

Open access
Mcgarry, James G., Klein-Nulend, Jenneke, Mullender, Margriet G., Prendergast, Patrick J.·2005·The FASEB Journal

Abstract

Bone undergoes continuous remodeling in response to mechanical loading. However, the underlying mechanisms by which bone cells respond to their changing mechanical environment, that is, strain in the load‐bearing matrix or fluid flow through the canalicular network, are not well understood. It has been established in vitro that bone cells respond differently to substrate strain and fluid shear stress treatments. Uncovering the mechanical basis of these differences represents a significant challenge to our understanding of cellular mechanotransduction and bone remodeling. To investigate this problem, we developed a biomechanical model of an adherent cell, to test the hypothesis that bone cells respond differently to 0.6 Pa fluid shear stress and 1,000 µε substrate strain stimulation because of qualitative and quantitative differences in the cellular deformation caused. Fluid shear stress loading conditions resulted in maximum displacements at the apical surface of the cell ∼8 times higher than those due to strain at the cellsubstrate interface and also caused higher stressing of all parts of the cell. Significantly, this shows that the deforming effects of fluid shear stress and strain on a cellular level are qualitatively different, which may provide a basis for explaining differences in bone cell responses to both stimuli as reported in several studies. Although our approach to modeling the morphology and complex physical environment of an adherent cell is certainly simplified, our results do show independent roles for fluid flow and strain as mechanical stimuli and highlight the importance of deformation on a cellular level in bone physiology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1096/fj.04-2210fje

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 197

Metadata

Authors
Mcgarry, J. G., Klein-Nulend, J., Mullender, M. G., & Prendergast, P. J.
Venue
The FASEB Journal
Publisher
Wiley
Published
2004-12-29
Volume
19
Issue
3
Pages
1-22
ISSN
  • 0892-6638 (ISSN-L)
  • 1530-6860
OpenAlex
W1756833589
Cited by
197
References
1
FWCI
2.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A comparison of strain and fluid shear stress in stimulating bone cell responses—a computational and experimental study. https://app.cochat.ai/papers/10.1096/fj.04-2210fje
The paper
Mcgarry, J. G., Klein-Nulend, J., Mullender, M. G., & Prendergast, P. J. (2005). A comparison of strain and fluid shear stress in stimulating bone cell responses—a computational and experimental study. The FASEB Journal. https://doi.org/10.1096/fj.04-2210fje

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.