Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 422

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic Effect

Sebel, P. S., Lang, E., Rampil, I. J., White, P. F., Cork, R., Jopling, M., Smith, N. T., Glass, P. S. A., Manberg, P.·1997·Anesthesia & Analgesia

Abstract

Bispectral analysis (BIS) of the electroencephalogram (EEG) has been shown in retrospective studies to predict whether patients will move in response to skin incision. This prospective multicenter study was designed to evaluate the real-time utility of BIS in predicting movement response to skin incision using a variety of general anesthetic techniques. Three hundred patients from seven study sites received an anesthetic regimen expected to give an approximately 50% movement response at skin incision. EEG was continuously recorded via an Aspect B-500 monitor and BIS was calculated in real time from bilateral frontocentral channels displayed on the monitor. Half of the patients were randomized to a treatment group in which anesthetic drug doses were increased to produce a lower BIS. In the control group, BIS was recorded, but no action taken on the data displayed. A determination of movement in response to skin incision was made in the 2 min succeeding incision. Retrospective pharmacodynamic modeling was performed using STANPUMP to estimate effect-site concentrations of intravenously administered anesthetics. BIS values were significantly higher in the control group (66 +/- 19) versus the BIS-guided group, in which additional anesthesia was administered to produce a lower BIS (51 +/- 19). The movement response rate was significantly higher in the control group at 43% compared with 13% in the BIS-guided group, but response rates were low at sites which used larger doses of opioids. Logistic regression analysis showed that BIS, estimated opioid effect-site concentrations, and heart rate (in that order) were the best predictors of movement at skin incision. This study demonstrates that dosing anesthetic drugs to lower BIS values achieves a lower probability of movement in response to surgical stimulation. BIS is a significant predictor of patient response to incision, but the utility of the BIS depends on the anesthetic technique being used. When drugs such as propofol or isoflurane are used as the primary anesthetic, changes in BIS correlate with the probability of response to skin incision. When opioid analgesics are used, the correlation to patient movement becomes much less significant, so that patients with apparently "light" EEG profiles may not move or otherwise respond to incision. Therefore, the adjunctive use of opioid analgesics confounds the use of BIS as a measure of anesthetic adequacy when movement response to skin incision is used as the primary end point.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-199704000-00035

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 422

Metadata

Authors
Sebel, P. S., Lang, E., Rampil, I. J., White, P. F., Cork, R., Jopling, M., Smith, N. T., Glass, P. S. A., & Manberg, P.
Venue
Anesthesia & Analgesia
Published
1997-04
Volume
84
Issue
4
Pages
891-899
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2133345804
Cited by
422
References
20
FWCI
24.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic Effect. https://app.cochat.ai/papers/10.1097/00000539-199704000-00035
The paper
Sebel, P. S., Lang, E., Rampil, I. J., White, P. F., Cork, R., Jopling, M., Smith, N. T., Glass, P. S. A., & Manberg, P. (1997). A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic Effect. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-199704000-00035

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.