The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Depth of Anesthesia and Bispectral Index Monitoring
Abstract
In a comprehensive review on monitoring anesthesia, Stanski (1) concluded that both specific defined stimuli and specific responses are needed to assess anesthetic depth. He stated that no unifying clinical measure of anesthetic depth spans all classes of anesthetic drugs and that clinical measures that appear relevant for a single drug may not be relevant if the drug is used in a combination. This conclusion is consistent with the view that the spectrum of effects that constitutes the state of general anesthesia should not be regarded as several components of anesthesia resulting from one anesthetic action, but represents separate pharmacological actions, even if the anesthesia is produced by one drug (2). As a result, the diversity of pharmacological actions that, in combination, provide anesthesia makes it impossible to determine the potency of different actions with one measure. Several studies support this view, some of which concern the molecular mechanisms of anesthetic actions. A difference in anesthetic potency between the optical isomers of isoflurane (3–5) and between isomers of etomidate (6) has been reported. In addition, several studies using site-directed mutagenesis showed that mutation of single critical amino acid residue within the gamma-aminobutyric acidA receptor can abolish the effects of enflurane (7) and etomidate (8). These results represent strong evidence that general anesthetics can act via specific molecular mechanisms. There are also new indications that different molecular mechanisms underlie different components of general anesthesia. Quinlan et al. (9) demonstrated that, in genetically engineered mice, the lack of the β subunit of gamma-aminobutyric acidA receptor results in a significant difference in the potency of enflurane and halothane for blockade of motor response to noxious stimulation but not for the hypnotic effect. These results correlate well with the results obtained in the studies by Rampil et al. (10), Rampil (11), and Antognini and Schwartz (12) that suggest that another inhaled anesthetic, isoflurane, provides one of the basic components of anesthesia-blockade of movement response to noxious stimulation by acting primarily on the spinal cord; this occurs when unconsciousness is achieved by the action of isoflurane on the brain. The difference in the anatomic substrate suggests that different physiologic mechanisms are involved in these two actions of isoflurane. The discussion on disparate mechanisms for different components of anesthesia attracts attention to this problem (13–16). The view that the search for a reliable index of anesthetic depth should be transformed into a search for separate indices of different components of anesthesia has been addressed in a number of articles (17–19). The common conclusion was that a monitor of anesthesia may measure only one of the components of general anesthesia, such as loss of consciousness, obtunding motor response, or hemodynamic response to noxious stimulation (19). Components of anesthesia that could be combined to achieve variable goals of anesthesia may not necessarily reach the level of central nervous system (CNS) depression that results in unconsciousness. For example, neuroleptanalgesia and conscious sedation provide sedation (psychological detachment), analgesia, and amnesia. These diverse components may reach different degrees of expression with various anesthetic combinations. Even with such seemingly similar components as sedation (alertness/sedation scale) and unconsciousness profoundly different outcomes are possible with the same drug combination. For example, benzodiazepine-opioid combinations result in a striking synergism for unconsciousness (20) but only an additive effect for sedation (alert-sleepy self-rating) (21). The same kind of difference in benzodiazepine-opioid interactions for hypnotic (loss of the righting reflex) and sedative (locomotor activity) effects was observed in rats (22). Is it feasible to measure the degrees of the separate specific effects with one common index? When anesthesia was produced by one drug with relatively low specificity of action, the depth of anesthesia was actually equated with the depth of CNS depression. Therefore, a single index reflecting CNS depression in general could be used as a measure of anesthesia. With the introduction of drugs with more specific anesthetic actions (especially ketamine), the wide use of opioids, and the use of light anesthesia, it became obvious that one index cannot be used successfully to reflect all components of anesthesia. If the term depth of anesthesia became irrelevant for major components of general anesthesia taken together, it could still be relevant for each of the components measured separately. One of the most important components of anesthesia is unconsciousness, which represents an all-or-none (quantal) response to an anesthetic. One can construct a dose-response curve by using quantal data (probability of resp
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sites of alcohol and volatile anaesthetic action on GABAA and glycine receptors
Mihic, S. J., Ye, Q., Wick, M. J., Koltchine, V. V., Krasowski, M. D., Finn, S. E., Mascia, M. P., Valenzuela, C. F., Hanson, K. K., Greenblatt, E. P., et al. (1997) · Nature · doi:10.1038/38738 · Cited by 1,219
Cited by
Bispectral index for improving anaesthetic delivery and postoperative recovery
Punjasawadwong, Y., Phongchiewboon, A., & Bunchungmongkol, N. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003843.pub3 · Cited by 449
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Romero, L. M., & Remage-Healey, L. (2000) · General and Comparative Endocrinology · doi:10.1006/gcen.2000.7491 · Cited by 259
Bispectral Index Monitoring during Sedation with Sevoflurane, Midazolam, and Propofol
Ibrahim, A. E., Taraday, J. K., & Kharasch, E. D. (2001) · Anesthesiology · doi:10.1097/00000542-200111000-00019 · Cited by 259
Metadata
- Authors
- Kissin, I.
- Venue
- Anesthesia & Analgesia
- Published
- 2000-05
- Volume
- 90
- Issue
- 5
- Pages
- 1114-1117
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2003073491
- Cited by
- 197
- References
- 1
- FWCI
- 14.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Depth of Anesthesia and Bispectral Index Monitoring. https://app.cochat.ai/papers/10.1097/00000539-200005000-00021
- The paper
- Kissin, I. (2000). Depth of Anesthesia and Bispectral Index Monitoring. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200005000-00021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.