The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Bispectral Index Monitoring during Sedation with Sevoflurane, Midazolam, and Propofol
Open accessAbstract
Background: Bispectral Index (BIS) has been used to measure sedation depth. Ideally, to guide anesthetic management, range of BIS scores at different sedation levels should not overlap, and BIS should be independent of drug used. This study assessed ability of BIS to predict sedation depth between sevoflurane, propofol, and midazolam. Quality of recovery was also compared. Methods: Patients undergoing surgery with local or regional anesthesia and sedation were randomized to sevoflurane (n = 23), midazolam (n = 21), or propofol (n = 22). Sedation was titrated to Observers's Assessment of Alertness-Sedation score of 3 (responds slowly to voice). BIS and Observers's Assessment of Alertness-Sedation were measured every 5 min. BIS prediction probability (PK) was compared between drugs. Recovery was assessed by BIS and Digit Symbol Substitution and memory tests. Results: Bispectral Index of responders to voice was significantly different from nonresponders (86 +/- 10 vs. 74 +/- 14, mean +/- SD; P < 0.001) However, wide variability and overlap in BIS were observed (25th-75th percentile, responders vs. non-responders: 79-96 vs. 65-83). BIS of responders was different for sevoflurane versus propofol and midazolam. BIS was a better predictor of propofol sedation than sevoflurane or midazolam (PK = 0.87 +/- 0.11, 0.76 +/- 0.01, and 0.69 +/- 0.02, respectively; P < 0.05). At 10 min after the procedure, 76, 48, and 24% of sevoflurane, propofol, midazolam patients, respectively, returned to baseline Digit Symbol Substitution scores (P < 0.05). Excitement-disinhibition occurred in 70, 36, and 5% of sevoflurane, propofol, and midazolam patients, respectively (P < 0.05). Conclusion: Individual BIS scores demonstrate significant variability, making it difficult to predict sedation depth. The relation between BIS and sedation depth may not be independent of anesthetic agent. Quality of recovery was similar between drugs, but excitement occurred frequently with sevoflurane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Concreteness, imagery, and meaningfulness values for 925 nouns.
Paivio, A., Yuille, J. C., & Madigan, S. A. (1968) · Journal of Experimental Psychology · doi:10.1037/h0025327 · Cited by 2,827
The Teacher's Word Book of 30, 000 Words
Thorndike, E. L., & Lorge, I. D. (2018) · Cited by 2,656
Validity and Reliability of the Observer??s: Assessment of Alertness/Sedation Scale
CHERNIK, D. A., GILLINGS, D., LAINE, H., HENDLER, J., SILVER, J. M., DAVIDSON, A. B., SCHWAM, E. M., & SIEGEL, J. L. (1990) · Journal of Clinical Psychopharmacology · doi:10.1097/00004714-199008000-00003 · Cited by 1,246
Liu, J., Singh, H., & White, P. F. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199701000-00033 · Cited by 432
A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic Effect
Sebel, P. S., Lang, E., Rampil, I. J., White, P. F., Cork, R., Jopling, M., Smith, N. T., Glass, P. S. A., & Manberg, P. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199704000-00035 · Cited by 422
Measuring the Performance of Anesthetic Depth Indicators
Smith, W. D., Dutton, R. C., & Smith, T. N. (1996) · Anesthesiology · doi:10.1097/00000542-199601000-00005 · Cited by 418
Drummond, J. C., & Weiskopf, R. B. (2000) · Anesthesiology · doi:10.1097/00000542-200009000-00039 · Cited by 366
Katoh, T., Suzuki, A., & Ikeda, K. (1998) · Anesthesiology · doi:10.1097/00000542-199803000-00014 · Cited by 333
Kearse, L. A., Rosow, C., Zaslavsky, A., Connors, P., Dershwitz, M., & Denman, W. (1998) · Anesthesiology · doi:10.1097/00000542-199801000-00007 · Cited by 309
Iselin-Chaves, I. A., Flaishon, R., Sebel, P. S., Howell, S., Gan, T. J., Sigl, J., Ginsberg, B., & Glass, P. S. A. (1998) · Anesthesia & Analgesia · doi:10.1097/00000539-199810000-00038 · Cited by 267
Cited by
Sieber, F. E., Zakriya, K. J., Gottschalk, A., Blute, M.-R., Lee, H. B., Rosenberg, P. B., & Mears, S. C. (2010) · Mayo Clinic Proceedings · doi:10.4065/mcp.2009.0469 · Cited by 417
Schüttler, J., Eisenried, A., Lerch, M., Fechner, J., Jeleazcov, C., & Ihmsen, H. (2020) · Anesthesiology · doi:10.1097/aln.0000000000003103 · Cited by 338
Update on Bispectral Index monitoring
Johansen, J. W. (2006) · Best Practice & Research Clinical Anaesthesiology · doi:10.1016/j.bpa.2005.08.004 · Cited by 313
Differential Effects of Propofol and Sevoflurane on Heart Rate Variability
Kanaya, N., Hirata, N., Kurosawa, S., Nakayama, M., & Namiki, A. (2003) · Anesthesiology · doi:10.1097/00000542-200301000-00009 · Cited by 294
Romero, L. M., & Remage-Healey, L. (2000) · General and Comparative Endocrinology · doi:10.1006/gcen.2000.7491 · Cited by 259
Metadata
- Authors
- Ibrahim, A. E., Taraday, J. K., & Kharasch, E. D.
- Venue
- Anesthesiology
- Published
- 2001-11-01
- Volume
- 95
- Issue
- 5
- Pages
- 1151-1159
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2101171063
- Cited by
- 259
- References
- 30
- FWCI
- 13.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bispectral Index Monitoring during Sedation with Sevoflurane, Midazolam, and Propofol. https://app.cochat.ai/papers/10.1097/00000542-200111000-00019
- The paper
- Ibrahim, A. E., Taraday, J. K., & Kharasch, E. D. (2001). Bispectral Index Monitoring during Sedation with Sevoflurane, Midazolam, and Propofol. Anesthesiology. https://doi.org/10.1097/00000542-200111000-00019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.