Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 204

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

“Motion-Resistant” Pulse Oximetry: A Comparison of New and Old Models

Barker, Steven J. · 2002 · Anesthesia & Analgesia

Abstract

Several pulse oximeter manufacturers have recently developed instruments that are claimed to be resistant to the effects of patient motion. We performed a laboratory volunteer experiment to compare the performances of several of these instruments, as well as some older models, during combinations of motion and hypoxemia. Twenty oximeters were studied. A motorized table produced different hand motions, and each motion was studied during both room air breathing and hypoxemia. Pulse oximeters on the nonmoving hand were used to provide control measurements for comparison. The Masimo SET((R)) pulse oximeter exhibited the best overall performance, with a performance index (percentage of time in which the SpO(2) reading is within 7% of control value) of 94%. The Agilent Viridia 24C was next, with an 84% index, followed by the Agilent CMS (80%), the Datex-Ohmeda 3740 (80%), and the Nellcor N-395 (69%). For comparison with older oximeter technology, the Criticare 5040 had an index of 28%. Recent technology changes have significantly improved pulse oximeter performance during motion artifact, with the Masimo oximeter leading the way. IMPLICATIONS. New improvements in pulse oximeter technology have resulted in significantly better accuracy and reliability during patient motion. The Masimo pulse oximeter demonstrated the best performance of the 20 instruments tested.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-200210000-00033

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Research works printed but not linked: 13

  1. Freund, 1991, J Clin Monit, 7, 253, 10.1007/BF01619270 · DOI
  2. Moller, 1993, Anesthesiology, 78, 436, 10.1097/00000542-199303000-00006 · DOI · Paper page
  3. Langton, 1990, Br J Anaesth, 65, 564, 10.1093/bja/65.4.564 · DOI
  4. Plummer, 1995, Anaesthesia, 50, 423, 10.1111/j.1365-2044.1995.tb05998.x · DOI
  5. Lie, 1997, Anaesthesia, 52, 450, 10.1111/j.1365-2044.1997.027-az026.x · doi:10.1111/j.1365-2044.1997.027-az026.x
  6. Plummer, 1997, J Clin Monit, 13, 109, 10.1023/A:1007303104811 · doi:10.1023/a:1007303104811
  7. Barker, 1997, Anesthesiology, 86, 101, 10.1097/00000542-199701000-00014 · DOI · Paper page
  8. Altman, 1983, Statistician, 32, 307, 10.2307/2987937 · DOI · Paper page
  9. Jopling, 2000, Anesthesiology, 93, A585, 10.1097/00000542-200009001-00585 · doi:10.1097/00000542-200009001-00585
  10. Bohnhorst, 2000, Crit Care Med, 28, 1565, 10.1097/00003246-200005000-00050 · DOI
  11. Hay, 2002, J Perinatol, 22, 360, 10.1038/sj.jp.7210740 · DOI · Paper page
  12. Torres, 2001, Crit Care Med, 29, A117
  13. Goldman, 2000, J Clin Monit, 16, 475, 10.1023/A:1011493521730 · DOI · Paper page

Cited by

See all 204

Metadata

Authors
Barker, S. J.
Venue
Anesthesia & Analgesia
Published
2002-10
Volume
95
Issue
4
Pages
967-972
ISSN
0003-2999 (ISSN-L)
OpenAlex
W1983782394
Cited by
204
References
1
FWCI
8.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: “Motion-Resistant” Pulse Oximetry: A Comparison of New and Old Models. https://app.cochat.ai/papers/10.1097/00000539-200210000-00033
The paper
Barker, S. J. (2002). “Motion-Resistant” Pulse Oximetry: A Comparison of New and Old Models. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200210000-00033

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.