Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 320

The DOI matches its Crossref record.

Anesthetic Doses Blocking Adrenergic (Stress) and Cardiovascular Responses to Incision—MAC BAR

Roizen, Michael F., Horrigan, Richard W., Frazer, Bryan M. · 1981 · Anesthesiology

Abstract

The reaction to stress, while vital to the conscious animal, may be detrimental to the surgical patient. To assess the stress-ablating action of different anesthetics (halothane, enflurane, morphine, and spinal) and anesthetic doses, we studied the responses in plasma norepinephrine, muscle movement, pupil diameter, heart rate, and blood pressure to induction of anesthesia and incision in 170 unpremedicated healthy adults. The age-adjusted dose (mean +/- SD) of anesthesia that blocked the adrenergic response in 50 per cent of individuals who had a skin incision (MAC BAR) was 1.45 +/- 0.08 MAC for halothane, 1.60 +/- 0.13 MAC for enflurane, or 1.13 +/- 0.09 +/- mg/kg for morphine sulfate (each anesthetic was given with 60 per cent nitrous oxide). No patient with a level of spinal anesthesia that blocked the pain of incision had an adrenergic response to incision. Increasing doses of halothane and morphine were associated with less of a cardiovascular response to incision (as measured by rate-pressure product); this was not true for enflurane. No patient with an adequate level of spinal anesthesia had a cardiovascular response to skin incision. The changes in heart rate, blood pressure, rate-pressure product, and plasma norepinephrine content that occurred with induction of anesthesia tended to equalize these values between patients, regardless of anesthetic dose, and for all individual and combined anesthetics. That is, if a patient's heart rate while awake was below 63 beats/min, heart rate tended to rise 58 per cent of the difference between heart rate while awake and 63 beats/min, and vice versa. Similarly, the change in blood pressure with induction averaged 75 per cent of the difference between systolic blood pressure while awake and 88 torr. The average for the change in rate-pressure product with induction was 79 per cent of the difference between rate-pressure product while awake and 5917 torr.beats/min. It was concluded that all the anesthetics tested can prevent the neuroendocrine response to skin incision at clinically attainable doses. Thus, comparisons of neuroendocrine stress during surgery require quantitation of anesthetic dose. If adverse effects of surgery are related to the neuroendocrine stress that surgical manipulations induce, the hypothesis "the less anesthetic the better" may be wrong.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-198105000-00008

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 320

Metadata

Authors
Roizen, M. F., Horrigan, R. W., & Frazer, B. M.
Venue
Anesthesiology
Published
1981-05-01
Volume
54
Issue
5
Pages
390-398
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1983336203
Cited by
320
References
0
FWCI
9.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Anesthetic Doses Blocking Adrenergic (Stress) and Cardiovascular Responses to Incision—MAC BAR. https://app.cochat.ai/papers/10.1097/00000542-198105000-00008
The paper
Roizen, M. F., Horrigan, R. W., & Frazer, B. M. (1981). Anesthetic Doses Blocking Adrenergic (Stress) and Cardiovascular Responses to Incision—MAC BAR. Anesthesiology. https://doi.org/10.1097/00000542-198105000-00008

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.