Anesthetic Requirements for Halothane in Young Children 0–1 Month and 1–6 Months of Age
Open accessThe DOI matches its Crossref record.
Abstract
In a previous study, the authors found that infants, in the first 6 months of life, required the highest minimum alveolar concentration (MAC) of any age group (1.09% halothane). Because only two neonates (0-31 days of age) were included in the original study and because profound depression of blood pressure and heart rate have been reported in neonates, the authors determined 1) whether the MAC of halothane in neonates (n = 12) differs from that in infants (1-6 months of age) (n = 12) and 2) whether the blood pressure and heart rate responses in neonates differ from those in infants at approximately 1 MAC. The authors found that the MAC of halothane in neonates, 0.87% +/- 0.03 SEM, was significantly lower (P less than 0.01) than that in infants, 1.20% +/- 0.06 SEM. With induction of anesthesia, the systolic blood pressure decreased 23% in neonates (P less than 0.05) and 34% in infants (P less than 0.005) from awake values. Similarly, the heart rate decreased 12% in neonates and 22% in infants (P less than 0.05). The incidence of hypotension (greater than 30% decrease in systolic blood pressure from awake) in neonates, 33%, was not significantly different from that in infants, 44%. The authors conclude that the MAC of halothane in neonates is 25% less than that in infants and significantly less than was thought previously. The MAC in infants is the highest of any age group. The decrease in blood pressure and the incidence of hypotension in neonates are similar to those in infants at approximately 1 MAC of halothane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pain and Its Effects in the Human Neonate and Fetus
Anand, K. J. S., & Hickey, P. R. (1987) · New England Journal of Medicine · doi:10.1056/nejm198711193172105 · Cited by 1,703
Bhananker, S. M., Ramamoorthy, C., Geiduschek, J. M., Posner, K. L., Domino, K. B., Haberkern, C. M., Campos, J. S., & Morray, J. P. (2007) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000268712.00756.dd · Cited by 720
Anand, K. J. S., & Carr, D. B. (1989) · Pediatric Clinics of North America · doi:10.1016/s0031-3955(16)36722-0 · Cited by 383
Age, Minimum Alveolar Anesthetic Concentration, and Minimum Alveolar Anesthetic Concentration-Awake
Eger, E. I. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200110000-00029 · Cited by 346
Effect of age on MAC in humans: a meta-analysis
Mapleson, W. W. (1996) · British Journal of Anaesthesia · doi:10.1093/bja/76.2.179 · Cited by 344
Minimum alveolar concentration: ongoing relevance and clinical utility
Aranake, A., Mashour, G. A., & Avidan, M. S. (2013) · Anaesthesia · doi:10.1111/anae.12168 · Cited by 186
Tips and traps analyzing pediatric PK data
Anderson, B. J., & Holford, N. H. G. (2011) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2011.03536.x · Cited by 163
Metadata
- Authors
- Lerman, J., Robinson, S., Willis, M. M., & Gregory, G. A.
- Venue
- Anesthesiology
- Published
- 1983-11-01
- Volume
- 59
- Issue
- 5
- Pages
- 421-424
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2064872722
- Cited by
- 200
- References
- 0
- FWCI
- 5.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.