Accuracy of Response of Six Pulse Oximeters to Profound Hypoxia
The DOI matches its Crossref record.
Abstract
Oxygen saturation, SpO2%, was recorded during rapidly induced 42.5 +/- 7.2-s plateaus of profound hypoxia at 40-70% saturation by 1 or 2 pulse oximeters from each of six manufacturers (NE = Nellcor N100, OH = Ohmeda 3700, NO = Novametrix 500 versions 2.2 and 3.3 (revised instrumentation), CR = Criticare CSI 501 + version .27 and version .28 in 501 & 502 (revised instrumentation), PC = PhysioControl Lifestat 1600, and MQ = Marquest/Minolta PulseOx 7). Usually, one probe of each pair was mounted on the ear, the other on a finger. Semi-recumbent, healthy, normotensive, non-smoking caucasian or asian volunteers (age range 18-64 yr) performed the test six to seven times each. After insertion of a radial artery catheter, subjects hyperventilated 3% CO2, 0-5% O2, balance N2. Saturation ScO2, computed on-line from mass spectrometer end-tidal PO2 and PCO2, was used to manually adjust FIO2 breath by breath to obtain a rapid fall to a hypoxic plateau lasting 30-45s, followed by rapid resaturation. Arterial HbO2% (Radiometer OSM-3) sampled near the end of the plateau averaged 55.5 +/- 7.5%. ScO2% (from the mass spectrometer) and SaO2% (from pH and PO2, by Corning 178) differed from HbO2% by + 0.2 +/- 3.6% and 0.4 +/- 2.8%, respectively. The mean and SD errors of pulse oximeters (vs. HbO2%) were: (table; see text) The plateaus were always long enough to permit instruments to demonstrate a plateau with ear probes, but finger probes sometimes failed to provide plateaus in subjects with peripheral vasoconstriction. Nonetheless, SpO2 read significantly too low with finger probes at 55% mean SaO2.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
BTS guideline for emergency oxygen use in adult patients
O'Driscoll, B. R., Howard, L. S., Davison, A. G., & on behalf of the British Thoracic Society (2008) · Thorax · doi:10.1136/thx.2008.102947 · Cited by 729
BTS guideline for oxygen use in adults in healthcare and emergency settings
O'Driscoll, B. R., Howard, L. S., Earis, J., & Mak, V (2017) · Thorax · doi:10.1136/thoraxjnl-2016-209729 · Cited by 679
Pulse oximetry: Principles and limitations
Sinex, J. E. (1999) · The American Journal of Emergency Medicine · doi:10.1016/s0735-6757(99)90019-0 · Cited by 481
Jubran, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2399-x · Cited by 401
Pulse oximetry: Analysis of theory, technology, and practice
Wukitsch, M. W., Petterson, M. T., Tobler, D. R., & Pologe, J. A. (1988) · Journal of Clinical Monitoring · doi:10.1007/bf01617328 · Cited by 306
An Ethiopian pattern of human adaptation to high-altitude hypoxia
Beall, C. M., Decker, M. J., Brittenham, G. M., Kushner, I., Gebremedhin, A., & Strohl, K. P. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.252649199 · Cited by 299
Meta-analysis of arterial oxygen saturation monitoring by pulse oximetry in adults
Jensen, L. A., Onyskiw, J. E., & Prasad, N. G. N. (1998) · Heart & Lung · doi:10.1016/s0147-9563(98)90086-3 · Cited by 243
Errors in 14 pulse oximeters during profound hypoxia
Severinghaus, J. W., Naifeh, K. H., & Koh, S. O. (1989) · Journal of Clinical Monitoring · doi:10.1007/bf01617877 · Cited by 217
“In our previous study [10], the responses o f the finger probes were found to be delayed, particularly in subjects with cold hands.”
BackgroundMethodInfluentialSelf-citationPotential errors in pulse oximetry: II. Effects of changes in saturation and signal quality*
WEBB, R. K., RALSTON, A. C., & RUNCIMAN, W. B. (1991) · Anaesthesia · doi:10.1111/j.1365-2044.1991.tb09411.x · Cited by 213
Kelleher, J. F. (1989) · Journal of Clinical Monitoring · doi:10.1007/bf01618369 · Cited by 202
Schnapp, L. M., & Cohen, N. H. (1990) · Chest · doi:10.1378/chest.98.5.1244 · Cited by 193
Signal processing methods for pulse oximetry
Rusch, T. L., Sankar, R., & Scharf, J. E. (1996) · Computers in Biology and Medicine · doi:10.1016/0010-4825(95)00049-6 · Cited by 185
Reliability of noninvasive oximetry in black subjects during exercise and hypoxia
Zeballos, R. J., & Weisman, I. M. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/144.6.1240 · Cited by 108
Gaskin, L., & Thomas, J. (1995) · Physiotherapy · doi:10.1016/s0031-9406(05)66819-8 · Cited by 14
Metadata
- Authors
- Severinghaus, J. W., & Naifeh, K. H.
- Venue
- Anesthesiology
- Published
- 1987-10-01
- Volume
- 67
- Issue
- 4
- Pages
- 551-558
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2086890520
- Cited by
- 312
- References
- 0
- FWCI
- 29.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.