Context-sensitive Half-time in Multicompartment: Pharmacokinetic Models for Intravenous Anesthetic Drugs
Open accessThe DOI matches its Crossref record.
Abstract
Elimination half-life is the pharmacokinetic parameter used most commonly to describe duration of pharmacologic action, including that expected of intravenous anesthetic drugs administered by continuous infusion. Little consideration has been given, however, to the relevance of elimination half-life in describing plasma (central compartment) drug concentrations in the context of relevant infusion durations. Therefore, simulations were performed with multicompartment pharmacokinetic models for six intravenous anesthetic drugs. These models had elimination half-lives ranging from 111 to 577 min. The input in each simulation was an infusion regimen designed to maintain a constant plasma drug concentration for durations ranging from 1 min to 8 h and until steady state. The time required for the plasma drug concentration to decline by 50% after terminating each infusion in each of the models was determined and was designated the "context-sensitive half-time," where "context" refers to infusion duration. The context-sensitive half-times were markedly different from their respective elimination half-lives and ranged from 1 to 306 min. The half-times were explained by posing each pharmacokinetic model in the form of a hydraulic model. These simulations demonstrate that elimination half-life is of no value in characterizing disposition of intravenous anesthetic drugs during dosing periods relevant to anesthesia. We propose that context-sensitive half-times are a useful descriptor of postinfusion central compartment kinetics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mould, D., & Upton, R. (2013) · CPT: Pharmacometrics & Systems Pharmacology · doi:10.1038/psp.2013.14 · Cited by 897
Clinical pharmacokinetics and pharmacodynamics of propofol
Sahinovic, M. M., Struys, M. M. R. F., & Absalom, A. R. (2018) · Clinical Pharmacokinetics · doi:10.1007/s40262-018-0672-3 · Cited by 809
Pharmacokinetics and Pharmacodynamics of Remifentanil: II. Model Application
Minto, C. F., Schnider, T. W., & Shafer, S. L. (1997) · Anesthesiology · doi:10.1097/00000542-199701000-00005 · Cited by 682
Midazolam and Other Benzodiazepines
Olkkola, K. T., & Ahonen, J. (2008) · Handbook of Experimental Pharmacology · doi:10.1007/978-3-540-74806-9_16 · Cited by 488
Population Pharmacokinetics of Propofol: A Multicenter Study
Schüttler, J., & Ihmsen, H. (2000) · Anesthesiology · doi:10.1097/00000542-200003000-00017 · Cited by 434
Propofol vs Midazolam for ICU Sedation
Hall, R. I., Sandham, D., Cardinal, P., Tweeddale, M., Moher, D., Wang, X., & Anis, A. H. (2001) · Chest · doi:10.1378/chest.119.4.1151 · Cited by 414
Egan, T. D., Minto, C. F., Hermann, D. J., Barr, J., Muir, K. T., & Shafer, S. L. (1996) · Anesthesiology · doi:10.1097/00000542-199604000-00009 · Cited by 409
Measured Context-sensitive Half-times of Remifentanil and Alfentanil
Kapila, A., Glass, P. S. A., Jacobs, J. R., Muir, K. T., Hermann, D. J., Shiraishi, M., Howell, S., & Smith, R. L. (1995) · Anesthesiology · doi:10.1097/00000542-199511000-00009 · Cited by 393
Self-citationPropofol: An Update of its Use in Anaesthesia and Conscious Sedation
Bryson, H. M., Fulton, B. R., & Faulds, D. (1995) · Drugs · doi:10.2165/00003495-199550030-00008 · Cited by 374
Remifentanil Pharmacokinetics and Pharmacodynamics: A Preliminary Appraisal
Egan, T. D. (1995) · Clinical Pharmacokinetics · doi:10.2165/00003088-199529020-00003 · Cited by 361
Schüttler, J., Eisenried, A., Lerch, M., Fechner, J., Jeleazcov, C., & Ihmsen, H. (2020) · Anesthesiology · doi:10.1097/aln.0000000000003103 · Cited by 338
Pharmacokinetics of Opioids in Liver Disease
Tegeder, I., L??tsch, J., & Geisslinger, G. (1999) · Clinical Pharmacokinetics · doi:10.2165/00003088-199937010-00002 · Cited by 306
Vuyk, J., Mertens, M. J., Olofsen, E., Burm, A. G. L., & Bovill, J. G. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00033 · Cited by 285
Clinical Pharmacokinetics of Alfentanil, Fentanyl and Sufentanil: An Update
Scholz, J., Steinfath, M., & Schulz, M. (1996) · Clinical Pharmacokinetics · doi:10.2165/00003088-199631040-00004 · Cited by 279
Veselis, R. A., Reinsel, R. A., Feshchenko, V. A., & Wronski, M. (1997) · Anesthesiology · doi:10.1097/00000542-199710000-00007 · Cited by 226
Wiltshire, H. R., Kilpatrick, G. J., Tilbrook, G. S., & Borkett, K. M. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318241f68a · Cited by 215
Size, Myths and the Clinical Pharmacokinetics of Analgesia in Paediatric Patients
Anderson, B. J., McKee, A. D., & Holford, N. H. G. (1997) · Clinical Pharmacokinetics · doi:10.2165/00003088-199733050-00001 · Cited by 210
Sedation and Analgesia in the Mechanically Ventilated Patient
Patel, S. B., & Kress, J. P. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201102-0273ci · Cited by 204
“Of critical importance is the understanding of a pharmacological principle referred to as the “context-sensitive half-time” (20, 21) (Figure 1).”
BackgroundRemimazolam besilate, a benzodiazepine, has been approved for general anesthesia!!
Masui, K. (2020) · Journal of Anesthesia · doi:10.1007/s00540-020-02755-1 · Cited by 123
Metadata
- Authors
- Hughes, M. A., Glass, P. S. A., & Jacobs, J. R.
- Venue
- Anesthesiology
- Published
- 1992-03-01
- Volume
- 76
- Issue
- 3
- Pages
- 334-341
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2078414113
- Cited by
- 784
- References
- 0
- FWCI
- 15.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.