Anesthetic Depth Defined Using Multiple Noxious Stimuli during Isoflurane/Oxygen Anesthesia: II. Hemodynamic Responses
The DOI matches its Crossref record.
Abstract
BACKGROUND: The hemodynamic effects of isoflurane have been studied extensively. However, most data are obtained from volunteers or patients in the absence of surgical stimulation. The hemodynamic responses to various stimulation patterns of different intensity have not been evaluated. METHODS: In 26 patients, the ability of isoflurane to suppress motor and hemodynamic reactions in response to noxious stimulations of variable degree (trapezius squeeze, tetanic stimulation, laryngoscopy, skin incision, and laryngoscopy plus intubation) was evaluated by measuring arterial blood pressure and heart rate before and after stimulation. RESULTS: At concentrations that inhibited motor response to these stimuli in 50% of all patients, systolic blood pressure increased by 9 (trapezius squeeze), 15 (tetanic stimulation), 23 (laryngoscopy), 35 (skin incision) and 49 (intubation) mmHg, and heart rate by 5 (trapezius squeeze), 15 (tetanic stimulation), 17 (laryngoscopy), 36 (skin incision), and 36 (intubation) min-1 compared to the prestimulation values. An analysis using multiple regression showed that blood pressure response was influenced most by the type of stimulation followed by the concomitantly occurring motor reaction, the anesthesia time, and least by the isoflurane concentration per se. A high isoflurane concentration had no influence on the magnitude of blood pressure or heart rate increase to stimulation, but it decreased the prestimulation blood pressure and slightly increased the prestimulation heart rate. Heart rate responses were less consistent than those of blood pressure. CONCLUSIONS: Isoflurane used as a sole agent is unable to suppress hemodynamic reactions (blood pressure and heart rate) to painful stimuli. A "normal" blood pressure following stimulation can be achieved only if prestimulation blood pressure is depressed to levels that may be clinically unacceptable. The lack of motor response is not an accurate predictor of the ability of an agent to depress hemodynamic reaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Muir III, W. W., Wiese, A. J., & March, P. A. (2003) · American Journal of Veterinary Research · doi:10.2460/ajvr.2003.64.1155 · Cited by 248
Kazama, T., Ikeda, K., & Morita, K. (1997) · Anesthesiology · doi:10.1097/00000542-199708000-00007 · Cited by 206
A Response Surface Analysis of Propofol–Remifentanil Pharmacodynamic Interaction in Volunteers
Kern, S. E., Xie, G., White, J. L., & Egan, T. D. (2004) · Anesthesiology · doi:10.1097/00000542-200406000-00007 · Cited by 206
“There are data to suggest that electrical tetany is a surrogate stimulus somewhat akin to the clinical stimulus of surgical skin incision.(8) In future work, it should be possible to relate these surrogate measures to clinical measures in a more sophisticated, quantitative way.”
BackgroundMouse Anesthesia: The Art and Science
Navarro, K. L., Huss, M., Smith, J. C., Sharp, P., Marx, J. O., & Pacharinsak, C. (2021) · ILAR Journal · doi:10.1093/ilar/ilab016 · Cited by 176
Katoh, T., Kobayashi, S., Suzuki, A., Iwamoto, T., Bito, H., & Ikeda, K. (1999) · Anesthesiology · doi:10.1097/00000542-199902000-00012 · Cited by 158
Seitsonen, E. R. J., Korhonen, I. K. J., Van Gils, M. J., Huiku, M., Lötjönen, J. M. P., Korttila, K. T., & Yli‐Hankala, A. M. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00654.x · Cited by 120
Metadata
- Authors
- Zbinden, A. M., Petersen-Felix, S., & Thomson, D. A.
- Venue
- Anesthesiology
- Published
- 1994-02-01
- Volume
- 80
- Issue
- 2
- Pages
- 261-267
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2086114942
- Cited by
- 207
- References
- 0
- FWCI
- 14.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.