Low-frequency Spectral Power of Heart Rate Variability Is Not a Specific Marker of Cardiac Sympathetic Modulation
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Background: Heart rate variability in the frequency domain has been proposed to reflect cardiac autonomic control. Therefore, measurement of heart rate variability may be useful to assess the effect of epidural anesthesia on cardiac autonomic tone. Accordingly, the effects of preganglionic cardiac sympathetic blockade by segmental epidural anesthesia were evaluated in humans on spectral power of heart rate variability. Specifically, the hypothesis that cardiac sympathetic blockade attenuates low-frequency spectral power, assumed to reflect cardiac sympathetic modulation, was tested. Methods: Ten subjects were studied while supine and during a 15-min 40 degrees head-up tilt both before and after cardiac sympathetic blockade by segmental thoracic epidural anesthesia (sensory block: C6-T6). ECG, arterial pressure, and respiratory excursion (Whitney gauge) were recorded, and a fast-Fourier-transformation was applied to 512-s data segments of heart rate derived from the digitized ECG at the end of each intervention. Results: With cardiac sympathetic blockade alone and the subjects supine, both low-frequency (LF, 0.06-0.15 Hz) and high-frequency (HF, 0.15-0.80 Hz) spectral power remained unchanged. During tilt, epidural anesthesia attenuated the evoked increase in heart rate (+11.min-1 +/- 7 SD vs. +6 +/- 7, P = 0.024). However, while during tilt cardiac sympathetic blockade significantly decreased the LF/HF ratio (3.68 +/- 2.52 vs. 2.83 +/- 2.15, P = 0.041 vs. tilt before sympathetic blockade), a presumed marker of sympathovagal interaction, absolute and fractional LF and HF power did not change. Conclusions: Although preganglionic cardiac sympathetic blockade reduced the LF/HF ratio during tilt, it did not alter spectral power in the LF band during rest or tilt. Accordingly, low-frequency spectral power is unlikely to specifically reflect cardiac sympathetic modulation in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Akselrod, S., Gordon, D., Ubel, F. A., Shannon, D. C., Berger, A. C., & Cohen, R. J. (1981) · Science · doi:10.1126/science.6166045 · Cited by 5,079
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Cardiovascular neural regulation explored in the frequency domain.
Malliani, A., Pagani, M., Lombardi, F., & Cerutti, S. (1991) · Circulation · doi:10.1161/01.cir.84.2.482 · Cited by 3,569
Assessment of autonomic function in humans by heart rate spectral analysis
Pomeranz, B., Macaulay, R. J., Caudill, M. A., Kutz, I., Adam, D., Gordon, D., Kilborn, K. M., Barger, A. C., Shannon, D. C., Cohen, R. J., et al. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.248.1.h151 · Cited by 2,876
Accuracy of assessment of cardiac vagal tone by heart rate variability in normal subjects.
Hayano, J., Sakakibara, Y., Yamada, A., Yamada, M., Mukai, S., Fujinami, T., Yokoyama, K., Watanabe, Y., & Takata, K. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90445-q · Cited by 746
Wallin, B. G., Esler, M., Dorward, P., Eisenhofer, G., Ferrier, C., Westerman, R., & Jennings, G. (1992) · The Journal of Physiology · doi:10.1113/jphysiol.1992.sp019217 · Cited by 298
Cited by
Heart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962
The LF/HF ratio does not accurately measure cardiac sympatho-vagal balance
Billman, G. E. (2013) · Frontiers in Physiology · doi:10.3389/fphys.2013.00026 · Cited by 1,401
Sympathovagal Balance: A Critical Appraisal
Eckberg, D. L. (1997) · Circulation · doi:10.1161/01.cir.96.9.3224 · Cited by 1,087
Reyes del Paso, G. A., Langewitz, W., Mulder, L. J. M., van Roon, A., & Duschek, S. (2013) · Psychophysiology · doi:10.1111/psyp.12027 · Cited by 954
Goldstein, D. S., Bentho, O., Park, M.-Y., & Sharabi, Y. (2011) · Experimental Physiology · doi:10.1113/expphysiol.2010.056259 · Cited by 846
“Low-frequency power considered alone does not consistently increase with orthostasis (Lipsitz et al. 1990; Hopf et al. 1995; Peles et al. 1995; Piccirillo et al. 1995; Vicek et al. 2008), despite approximately a doubling of plasma noradrenaline levels, although there are exceptions (Peles et al.…”
Background
Metadata
- Authors
- Hopf, H.-B., Skyschally, A., Heusch, G., & Peters, J.
- Venue
- Anesthesiology
- Published
- 1995-03-01
- Volume
- 82
- Issue
- 3
- Pages
- 609-619
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2076975832
- Cited by
- 142
- References
- 6
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-frequency Spectral Power of Heart Rate Variability Is Not a Specific Marker of Cardiac Sympathetic Modulation. https://app.cochat.ai/papers/10.1097/00000542-199503000-00002
- The paper
- Hopf, H.-B., Skyschally, A., Heusch, G., & Peters, J. (1995). Low-frequency Spectral Power of Heart Rate Variability Is Not a Specific Marker of Cardiac Sympathetic Modulation. Anesthesiology. https://doi.org/10.1097/00000542-199503000-00002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.