Heat Balance and Distribution during the Core-Temperature Plateau in Anesthetized Humans
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Background: Once triggered, intraoperative thermoregulatory vasoconstriction is remarkably effective in preventing further hypothermia. Protection results from both vasoconstriction-induced decrease in cutaneous heat loss and altered distribution of body heat. However, the independent contributions of each mechanism have not been quantified. Accordingly, we evaluated overall heat balance and distribution of heat within the body during the core-temperature plateau. Methods: Nine minimally clothed male volunteers were anesthetized with propofol and isoflurane and maintained in an approximately 22 degrees C environment. They were monitored for approximately 2 h before vasoconstriction and for 3 h subsequently. Overall heat balance was determined from the difference between cutaneous heat loss (thermal flux transducers) and metabolic heat production (oxygen consumption). Arm and leg tissue heat contents were determined from 19 intramuscular temperatures, ten skin temperatures, and "deep" foot temperature. Heat constrained by vasoconstriction to the trunk and head was calculated by subtracting the expected change in that region (overall heat balance multiplied by the fractional weight of the trunk and head) from the actual change (change in distal esophageal temperature multiplied by the specific heat of human tissue and the weight of the trunk and head); the result represents the amount by which core heat exceeded that which would be expected based on overall heat balance, assuming that the change was evenly distributed throughout the body. Results: Vasoconstriction and passive tissue cooling decreased heat loss but not to the level of heat production. Consequently, heat loss exceeded metabolic heat production throughout the study. Core temperature decreased approximately 1.3 C during the 2-h prevasoconstriction period; however, core temperature remained virtually constant during the subsequent 3 h. In the 3 h after vasoconstriction, arm and leg heat content decreased 57 +/- 9 kcal, and vasoconstriction constrained 22 +/- 8 kcal to the trunk and head. Conclusions: These results confirm the efficacy of thermo-regulatory vasoconstriction in preventing additional core hypothermia. Decreased cutaneous heat loss and constraint of metabolic heat to the core thermal compartment contributed to the plateau.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The measurement of volume changes in human limbs
Whitney, R. J. (1953) · The Journal of Physiology · doi:10.1113/jphysiol.1953.sp004926 · Cited by 1,489
The estimation of areas of burns
Cc, L. (1944) · Medical Entomology and Zoology · Cited by 757
LASER DOPPLER MEASUREMENT OF CUTANEOUS BLOOD FLOW
Holloway, G. A., & Watkins, D. W. (1977) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12507665 · Cited by 538
Heat Flow and Distribution during Induction of General Anesthesia
Matsukawa, T., Sessler, D. I., Sessler, A. M., Schroeder, M., Ozaki, M., Kurz, A., & Cheng, C. (1995) · Anesthesiology · doi:10.1097/00000542-199503000-00008 · Cited by 528
Self-citationSkin-surface Temperature Gradients Correlate with Fingertip Blood Flow in Humans
Rubinstein, E. H., & Sessler, D. I. (1990) · Anesthesiology · doi:10.1097/00000542-199009000-00027 · Cited by 388
Self-citationPropofol Linearly Reduces the Vasoconstriction and Shivering Thresholds
Matsukawa, T., Kurz, A., Sessler, D. I., Bjorksten, A. R., Merrifield, B., & Cheng, C. (1995) · Anesthesiology · doi:10.1097/00000542-199505000-00012 · Cited by 330
Self-citationTRANSEPIDERMAL WATER LOSS IN NEWBORN INFANTS: III. Relation to Gestational Age
HAMMARLUND, K., & SEDIN, G. (2008) · Acta Paediatrica · doi:10.1111/j.1651-2227.1979.tb08214.x · Cited by 315
A new approach for the estimation of body composition: infrared interactance
Conway, J., Norris, K., & Bodwell, C. (1984) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/40.6.1123 · Cited by 311
Determination of esophageal probe insertion length based on standing and sitting height
Mekjavic, I. B., & Rempel, M. E. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.69.1.376 · Cited by 249
Computation of mean body temperature from rectal and skin temperatures.
Colin, J., Timbal, J., Houdas, Y., Boutelier, C., & Guieu, J. D. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.3.484 · Cited by 186
Hynson, J. M., Sessler, D. I., Moayeri, A., McGuire, J., & Schroeder, M. (1993) · Anesthesiology · doi:10.1097/00000542-199308000-00005 · Cited by 178
Self-citationCorrelation of thermal properties of some human tissue with water content.
Cooper, T., & Trezek, G. J. (1971) · PubMed · Cited by 162
Perioperative Thermal Insulation
Sessler, D. I., McGuire, J., & Sessler, A. M. (1991) · Anesthesiology · doi:10.1097/00000542-199105000-00012 · Cited by 148
Self-citationOxygen Uptake during Recovery Following Naloxone Relationship with Intraoperative Heat Loss
Just, B., Delva, E., Camus, Y., & Lienhart, A. (1992) · Anesthesiology · doi:10.1097/00000542-199201000-00009 · Cited by 144
Joris, J. L., Ozaki, M., Sessler, D. I., Hardy, A. F., Lamy, M., McGuire, J., Blanchard, D., Schroeder, M., & Moayeri, A. (1994) · Anesthesiology · doi:10.1097/00000542-199402000-00006 · Cited by 126
Self-citationThe Thermoregulatory Threshold in Humans during Nitrous Oxide-Fentanyl Anesthesia
Sessler, D. I., Olofsson, C. I., & Rubinstein, E. H. (1988) · Anesthesiology · doi:10.1097/00000542-198809000-00012 · Cited by 113
Self-citationBelani, K. G., Sessler, D. I., Sessler, A. M., Schroeder, M., McGuire, J., Merrifield, B., Washington, D. E., & Moayeri, A. (1993) · Anesthesiology · doi:10.1097/00000542-199305000-00008 · Cited by 92
Self-citationSessler, D. I., McGuire, J., Hynson, J. M., Moayeri, A., & Heler, T. (1992) · Anesthesiology · doi:10.1097/00000542-199205000-00002 · Cited by 91
Self-citationAbsence of Nonshivering Thermogenesis in Anesthetized Adult Humans
Moayeri, A., McGuire, J., Hynson, J. M., & Sessler, D. (1993) · Anesthesiology · doi:10.1097/00000542-199310000-00010 · Cited by 81
Self-citationAltered control of skin blood flow at high skin and core temperatures
WYSS, C. R., Brengelmann, G. L., Johnson, J. M., Rowell, L. B., & Silverstein, D. (1975) · Journal of Applied Physiology · doi:10.1152/jappl.1975.38.5.839 · Cited by 78
Thermoregulatory Vasoconstriction Impairs Active Core Cooling
Kurz, A. M., Sessler, D. I., Birnbauer, F., Illievich, U. M., & Spiss, C. K. (1995) · Anesthesiology · doi:10.1097/00000542-199504000-00008 · Cited by 73
Self-citationErrors in Measurement of Oxygen Uptake due to Anesthetic Gases
Aukburg, S. J., Geer, R. T., Wollman, H., & Neufeld, G. R. (1985) · Anesthesiology · doi:10.1097/00000542-198501000-00011 · Cited by 58
Improvement of deep body thermometer for man
Kobayashi, T., Nemoto, T., Kamiya, A., & Togawa, T. (1975) · Annals of Biomedical Engineering · doi:10.1007/bf02363069 · Cited by 56
Bissonnette, B., & Sessler, D. I. (1992) · Anesthesiology · doi:10.1097/00000542-199203000-00011 · Cited by 55
Self-citationErrors in heat flux measurements due to the thermal resistance of heat flux disks
Ducharme, M. B., Frim, J., & Tikuisis, P. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.69.2.776 · Cited by 42
Cited by
Temperature Monitoring and Perioperative Thermoregulation
Sessler, D. I., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31817f6d76 · Cited by 758
“Fortunately, maximum intensity is finally reached and, once reached, is effective, usually preventing further core hypothermia.(10)”
BackgroundSelf-citationMild Perioperative Hypothermia
Sessler, D. I. (1997) · New England Journal of Medicine · doi:10.1056/nejm199706123362407 · Cited by 659
Self-citationComplications and Treatment of Mild Hypothermia
Sessler, D. I. (2001) · Anesthesiology · doi:10.1097/00000542-200108000-00040 · Cited by 640
Self-citationPerioperative thermoregulation and heat balance
Sessler, D. I. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00981-2 · Cited by 593
Self-citationSessler, D. I., & Todd, M. M. (2000) · Anesthesiology · doi:10.1097/00000542-200002000-00042 · Cited by 557
Self-citation
Metadata
- Authors
- Kurz, A., Sessler, D. I., Christensen, R., & Dechert, M.
- Venue
- Anesthesiology
- Published
- 1995-09-01
- Volume
- 83
- Issue
- 3
- Pages
- 491-499.
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2128106614
- Cited by
- 194
- References
- 25
- FWCI
- 7.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.