Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 333

The DOI matches its Crossref record.

Electroencephalographic Derivatives as a Tool for Predicting the Depth of Sedation and Anesthesia Induced by Sevoflurane

Open access
Katoh, Takasumi, Suzuki, Akira, Ikeda, Kazuyuki·1998·Anesthesiology

Abstract

Background: The electroencephalogram (EEG) has been evaluated as a tool for measuring depth of anesthesia, but the use of the EEG monitoring is still controversial. The current study was designed to evaluate the accuracy of three EEG parameters and anesthetic concentration for predicting depth of sedation and anesthesia during sevoflurane anesthesia Methods: One low and one high equilibrated concentration ranging from 0.2-1.8% were assigned randomly and administered consecutively to 69 patients. The bispectral index (BIS; version 3.2), 95% spectral edge frequency (SEF), and median power frequency (MPF) were obtained from a bipolar frontomastoid (Fp1-A1, Fp2-A2) montage using an EEG monitor. Sedation was assessed using the responsiveness portion of the observer's assessment of alertness-sedation scale. In the second phase of the study, the 47 patients who were scheduled to have skin incisions were observed for purposeful movement in response to skin incision at sevoflurane concentrations between 1.6% and 2.4%. The relation among BIS, 95% SEF, MPF, sevoflurane concentration, sedation score, and movement or no movement after skin incision, was determined. Prediction probability values for EEG parameters and sevoflurane concentration to predict depth of sedation and anesthesia were also calculated. Results: The BIS and sevoflurane concentration correlated closely with the sedation score. Both 95% SEF and MPF changed significantly but biphasically with increasing sedation. The prediction probability values for BIS and sevoflurane concentration were 0.966 and 0.945, respectively, indicating a high predictive performance for depth of sedation. No EEG parameters predicted movement after skin incision better than chance alone. Conclusions: Parameters derived from EEG, such as BIS, and 95% SEF are reliable guides to the depth of sedation, but not to the adequacy of anesthesia level for preventing movement during sevoflurane anesthesia.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199803000-00014

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 333

Metadata

Authors
Katoh, T., Suzuki, A., & Ikeda, K.
Venue
Anesthesiology
Published
1998-03-01
Volume
88
Issue
3
Pages
642-650
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2085794477
Cited by
333
References
0
FWCI
19.71
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electroencephalographic Derivatives as a Tool for Predicting the Depth of Sedation and Anesthesia Induced by Sevoflurane. https://app.cochat.ai/papers/10.1097/00000542-199803000-00014
The paper
Katoh, T., Suzuki, A., & Ikeda, K. (1998). Electroencephalographic Derivatives as a Tool for Predicting the Depth of Sedation and Anesthesia Induced by Sevoflurane. Anesthesiology. https://doi.org/10.1097/00000542-199803000-00014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.