Volume Kinetics of Ringer Solution, Dextran 70, and Hypertonic Saline in Male Volunteers
Open accessAbstract
Background: A knowledge of the distribution of different fluids given by intravenous infusion is basic to the understanding of the effects of fluid therapy. Therefore, a mathematical model was tested to analyze the volume kinetics of three types of fluids. Methods: The authors infused 25 ml/kg of Ringer acetate solution, 5 ml/kg of 6% dextran 70 in 0.9% NaCl, and 3 ml/kg of 7.5% NaCl over 30 min in 8 male volunteers aged from 25 to 36 years (mean, 31 years) and measured the changes in total hemoglobin, serum albumin, and total blood water over time. The changes were expressed as fractioned dilution and then plotted against time. The curves were fitted to a one-volume and a two-volume model, which allowed an estimation of the size of the body fluid space expanded by the fluid (V) and the elimination rate constant (k(r) to be made. Results: The changes in blood water concentration indicated a mean size of V of 5.9 1 (+/- 0.8, SEM) for Ringer's solution, 2.6 (+/- 0.3) 1 for dextran, and 1.2 (+/- 0.1) 1 for hypertonic saline. The corresponding values of k(r) were 94 (+/- 42), 12 (+/- 6), and 30 (+/- 4) ml/min, respectively. Blood hemoglobin indicated a degree of dilution similar to that indicated by blood water. Serum albumin indicated a more pronounced dilution, which resulted in a larger expandable volume and a greater mean square error for the curvefitting. The larger volume obtained for serum albumin can probably be explained by a loss of intravascular albumin into the tissues along with the infused fluid. Conclusions: The distribution of intravenous fluids can be analyzed by a kinetic model adapted for fluid spaces, but slightly different results are obtained, depending on the marker used to indicate dilution of the primary fluid space. Analysis and simulation of plasma volume expansion by this model is a tool that can help the anesthetist to better plan fluid therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fitting curves to data using nonlinear regression: a practical and nonmathematical review
Motulsky, H. J., & Ransnas, L. A. (1987) · The FASEB Journal · doi:10.1096/fasebj.1.5.3315805 · Cited by 1,327
Cited by
(Ab)normal saline and physiological Hartmann's solution: a randomized double-blind crossover study
REID, F., LOBO, D. N., WILLIAMS, R. N., ROWLANDS, B. J., & ALLISON, S. P. (2003) · Clinical Science · doi:10.1042/cs1040017 · Cited by 284
Circadian changes in the sweating-to-vasoconstriction interthreshold range
Tayefeh, F., Plattner, O., Sessler, D. I., Ikeda, T., & Marder, D. (1998) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/s004240050530 · Cited by 79
Metadata
- Authors
- Svensen, C., & Hahn, R. G.
- Venue
- Anesthesiology
- Published
- 1997-08-01
- Volume
- 87
- Issue
- 2
- Pages
- 204-212
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2086340914
- Cited by
- 164
- References
- 1
- FWCI
- 5.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Volume Kinetics of Ringer Solution, Dextran 70, and Hypertonic Saline in Male Volunteers. https://app.cochat.ai/papers/10.1097/00000542-199708000-00006
- The paper
- Svensen, C., & Hahn, R. G. (1997). Volume Kinetics of Ringer Solution, Dextran 70, and Hypertonic Saline in Male Volunteers. Anesthesiology. https://doi.org/10.1097/00000542-199708000-00006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.