CoChat

On the Relevance of “Clinically Relevant Concentrations” of Inhaled Anesthetics in In Vitro Experiments

Open access
Eckenhoff, Roderic G., Johansson, Jonas S. · 1999 · Anesthesiology
Cited by 74

The DOI matches its Crossref record.

Abstract

THE use of the phrase, “clinically relevant anesthetic concentrations” has become so enshrined in in vitro research on anesthetic action that its importance has assumed a prominent and rarely questioned status. To review, the yardstick by which most studies of anesthetic action are measured is sensitivity, or whether significant effects on in vitro systems can be measured at concentrations of general anesthetics used in people. Our contemporary inhalational anesthetics, halothane, isoflurane, and sevoflurane, produce aqueous concentrations of approximately 0.3 mM at 1 minimum alveolar concentration (MAC) and at 37°C. 1Thus, the logic goes, for an in vitro preparation or some other model system, to be in any way clinically relevant, it too must be affected, preferably by 50% of some maximal response at the same concentration. There are several implicit, but rarely discussed, assumptions underlying this logic, which we will consider in the following paragraphs.Most in vitro responses to a drug or ligand are nonlinear and, when plotted against the log of concentration, fit a sigmoid relation (Hill or logistic equation) reasonably well. Such relations are characterized as being “saturable,” meaning that progressively smaller increases in the target response occur with increases in ligand concentration beyond a specific point. If this in vitro response directly controls some behavior of an organism, one might also expect that behavior to reach a maximum, or “ceiling,” as the administered dose of the drug is increased. But is anesthesia saturable? It depends on how we define a state that we know very little about. The popular operational definition is the absence of a motor response to a noxious stimulus in an unparalyzed animal. This is known also as the MAC response (m inimum a lveolar c oncentration of inhaled anesthetic to prevent this response in 50% of a population). 2This is a categoric (binomial in this case) definition, and any such definition of necessity results in a saturable response. However, does an arbitrary behavioral definition require that the underlying central nervous system (CNS) events be saturable? Although the MAC response is a relatively clear behavioral endpoint, in terms of CNS function it is considerably less clear. We know that all noxious stimuli are not equal and that the dose–response curve for a simple skin incision, for example, is different from that describing intubation of the trachea. 3That different CNS functions have different sensitivities is also shown by the existence of the MAC-awake, 4and MAC-bar 5values. Further, no discrete electroencephalographic changes have been identified as indicating the achievement of MAC concentrations. 6Brain electrical activity becomes progressively depressed until approximately 3 MAC (approaching 1 mM aqueous concentration) for many of our agents 7until cardiovascular depression becomes critical. If cardiovascular and respiratory components are removed, as in, for example, cell culture, reversible influences of these compounds can be measured well above 3 MAC. 8Such progressive actions of anesthetics speak against finding a saturable CNS action that underlies binomial responses exemplified by MAC, and are more likely explained by progressive, simultaneous actions at many targets of comparable sensitivity. Alternatively, progressive CNS dysfunction could result from a more layered “sequential” action on progressively less-sensitive targets. If the latter is true, it may be reasonable to use sensitivity to identify targets underlying each response (although see discussion of Kd/EC50relation below), but only if one proposes that important single targets are responsible for each specific endpoint. However, if the progressive simultaneous action model holds, then the response of the whole organism is an integrated, fluctuating, nonlinear result of effects at many sites, and it makes little sense to use sensitivity to select among them. Because we really do not know the underlying pharmacologic basis for any of the actions of inhaled anesthetics, distinction between the simultaneous or sequential models is not yet possible, and, therefore, using sensitivity to clinically relevant anesthetic concentrations as a way of relating in vitro responses to CNS function must be viewed with considerable caution.Other than EC50or MAC values, dose–response relations contain additional useful information. For example, the steepness, or slope, is often used to gauge the degree of cooperativity of events that contribute to the observed response. In a well-known example of this, oxygen binding to hemoglobin shows a Hill slope of about three, reflecting the cooperative interaction between the binding of successive oxygen molecules. Binding interactions involving a single ligand, or multiple ligands binding to a single protein at noninteracting sites, typically show Hill slopes of around one. It is useful to keep in mind that about a 100-fold increase in ligand c

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199909000-00039

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 74

Metadata

Authors
Eckenhoff, R. G., & Johansson, J. S.
Venue
Anesthesiology
Published
1999-09-01
Volume
91
Issue
3
Pages
856-856
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2077999442
Cited by
74
References
0
FWCI
5.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On the Relevance of “Clinically Relevant Concentrations” of Inhaled Anesthetics in In Vitro Experiments. https://app.cochat.ai/papers/10.1097/00000542-199909000-00039
The paper
Eckenhoff, R. G., & Johansson, J. S. (1999). On the Relevance of “Clinically Relevant Concentrations” of Inhaled Anesthetics in In Vitro Experiments. Anesthesiology. https://doi.org/10.1097/00000542-199909000-00039

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.