Comparable Postoperative Pulmonary Atelectasis in Patients Given 30% or 80% Oxygen during and 2 Hours after Colon Resection

Akça, Ozan, Podolsky, Andrea, Eisenhuber, Edith, Panzer, Oliver, Hetz, Hubert, Lampl, Karl, Lackner, Franz X., Wittmann, Karin, Grabenwoeger, Florian, Kurz, Andrea, Schultz, Anette-Marie, Negishi, Chiharu, Sessler, Daniel I. · 1999 · Anesthesiology

Abstract

Background: High concentrations of inspired oxygen are associated with pulmonary atelectasis but also provide recognized advantages. Consequently, the appropriate inspired oxygen concentration for general surgical use remains controversial. The authors tested the hypothesis that atelectasis and pulmonary dysfunction on the first postoperative day are comparable in patients given 30% or 80% perioperative oxygen. Methods: Thirty patients aged 18-65 yr were anesthetized with isoflurane and randomly assigned to 30% or 80% oxygen during and for 2 h after colon resection. Chest radiographs and pulmonary function tests (forced vital capacity and forced expiratory volume) were obtained preoperatively and on the first postoperative day. Arterial blood gas measurements were obtained intraoperatively, after 2 h of recovery, and on the first postoperative day. Computed tomography scans of the chest were also obtained on the first postoperative day. Results: Postoperative pulmonary mechanical function was significantly reduced compared with preoperative values, but there was no difference between the groups at either time. Arterial gas partial pressures and the alveolar-arterial oxygen difference were also comparable in the two groups. All preoperative chest radiographs were normal. Postoperative radiographs showed atelectasis in 36% of the patients in the 30%-oxygen group and in 44% of those in the 80%-oxygen group. Relatively small amounts of pulmonary atelectasis (expressed as a percentage of total lung volume) were observed on the computed tomography scans, and the percentages (mean +/- SD) did not differ significantly in the patients given 30% oxygen (2.5% +/- 3.2%) or 80% oxygen (3.0% +/- 1.8%). These data provided a 99% chance of detecting a 2% difference in atelectasis volume at an alpha level of 0.05. Conclusions: Lung volumes, the incidence and severity of atelectasis, and alveolar gas exchange were comparable in patients given 30% and 80% perioperative oxygen. The authors conclude that administration of 80% oxygen in the perioperative period does not worsen lung function. Therefore, patients who may benefit from generous oxygen partial pressures should not be denied supplemental perioperative oxygen for fear of causing atelectasis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199910000-00019

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 173

Metadata

Authors
Akça, O., Podolsky, A., Eisenhuber, E., Panzer, O., Hetz, H., Lampl, K., Lackner, F. X., Wittmann, K., Grabenwoeger, F., Kurz, A., Schultz, A.-M., Negishi, C., & Sessler, D. I.
Venue
Anesthesiology
Published
1999-10-01
Volume
91
Issue
4
Pages
991-991
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1996737049
Cited by
173
References
0
FWCI
4.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparable Postoperative Pulmonary Atelectasis in Patients Given 30% or 80% Oxygen during and 2 Hours after Colon Resection. https://app.cochat.ai/papers/10.1097/00000542-199910000-00019
The paper
Akça, O., Podolsky, A., Eisenhuber, E., Panzer, O., Hetz, H., Lampl, K., Lackner, F. X., Wittmann, K., Grabenwoeger, F., Kurz, A., Schultz, A.-M., Negishi, C., & Sessler, D. I. (1999). Comparable Postoperative Pulmonary Atelectasis in Patients Given 30% or 80% Oxygen during and 2 Hours after Colon Resection. Anesthesiology. https://doi.org/10.1097/00000542-199910000-00019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.