Comparable Postoperative Pulmonary Atelectasis in Patients Given 30% or 80% Oxygen during and 2 Hours after Colon Resection
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Background: High concentrations of inspired oxygen are associated with pulmonary atelectasis but also provide recognized advantages. Consequently, the appropriate inspired oxygen concentration for general surgical use remains controversial. The authors tested the hypothesis that atelectasis and pulmonary dysfunction on the first postoperative day are comparable in patients given 30% or 80% perioperative oxygen. Methods: Thirty patients aged 18-65 yr were anesthetized with isoflurane and randomly assigned to 30% or 80% oxygen during and for 2 h after colon resection. Chest radiographs and pulmonary function tests (forced vital capacity and forced expiratory volume) were obtained preoperatively and on the first postoperative day. Arterial blood gas measurements were obtained intraoperatively, after 2 h of recovery, and on the first postoperative day. Computed tomography scans of the chest were also obtained on the first postoperative day. Results: Postoperative pulmonary mechanical function was significantly reduced compared with preoperative values, but there was no difference between the groups at either time. Arterial gas partial pressures and the alveolar-arterial oxygen difference were also comparable in the two groups. All preoperative chest radiographs were normal. Postoperative radiographs showed atelectasis in 36% of the patients in the 30%-oxygen group and in 44% of those in the 80%-oxygen group. Relatively small amounts of pulmonary atelectasis (expressed as a percentage of total lung volume) were observed on the computed tomography scans, and the percentages (mean +/- SD) did not differ significantly in the patients given 30% oxygen (2.5% +/- 3.2%) or 80% oxygen (3.0% +/- 1.8%). These data provided a 99% chance of detecting a 2% difference in atelectasis volume at an alpha level of 0.05. Conclusions: Lung volumes, the incidence and severity of atelectasis, and alveolar gas exchange were comparable in patients given 30% and 80% perioperative oxygen. The authors conclude that administration of 80% oxygen in the perioperative period does not worsen lung function. Therefore, patients who may benefit from generous oxygen partial pressures should not be denied supplemental perioperative oxygen for fear of causing atelectasis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Oxygen-Dependent Microbial Killing by Phagocytes: (First of Two Parts)
Babior, B. M. (1978) · New England Journal of Medicine · doi:10.1056/nejm197803232981205 · Cited by 2,486 · cited 1×
“Oxidative killing is the major defense against surgical wound infection.(25) Therefore, it is not surprising that tissue oxygen tension is highly correlated with the risk of surgical wound infection.”
BackgroundEffects of Anesthesia and Paralysis on Diaphragmatic Mechanics in Man
Froese, A. B., & Bryan, A. C. (1974) · Anesthesiology · doi:10.1097/00000542-197409000-00006 · Cited by 789 · cited 1×
“Surgical factors also contribute to ventilation–perfusion mismatch by causing regional differences in diaphragmatic movement and changes in the elastic properties of the lung.(35,36) Intestinal distension and restrictive abdominal bandages further impair recovery of normal diaphragm function.”
BackgroundBendixen, H. H., Whyte, H., & Laver, M. B. (1963) · New England Journal of Medicine · doi:10.1056/nejm196311072691901 · Cited by 745
Gattinoni, L., Pesenti, A., Bombino, M., Baglioni, S., Rivolta, M., Rossi, F., Rossi, G., Fumagalli, R., Marcolin, R., Mascheroni, D., et al. (1988) · Anesthesiology · doi:10.1097/00000542-198812000-00005 · Cited by 664
Wound Tissue Oxygen Tension Predicts the Risk of Wound Infection in Surgical Patients
Hopf, H. W. (1997) · Archives of Surgery · doi:10.1001/archsurg.1997.01430330063010 · Cited by 635 · cited 1×
“Therefore, it is not surprising that tissue oxygen tension is highly correlated with the risk of surgical wound infection.(26) Collagen deposition and scar formation are also directly dependent on tissue oxygen tension.”
BackgroundPulmonary Densities during Anesthesia with Muscular Relaxation—A Proposal of Atelectasis
Brismar, B., Hedenstierna, G., Lundquist, H., Strandberg, Å., Svensson, L., & Tokics, L. (1985) · Anesthesiology · doi:10.1097/00000542-198504000-00009 · Cited by 582 · cited 1×
“However, it was subsequently shown that atelectasis nonetheless develops as soon as treatment is discontinued.(38) High inspired oxygen concentrations—even for brief periods of time—have been shown to induce atelectasis.”
BackgroundWound Hypoxia and Acidosis Limit Neutrophil Bacterial Killing Mechanisms
Allen, D. B. (1997) · Archives of Surgery · doi:10.1001/archsurg.1997.01430330057009 · Cited by 500 · cited 1×
“Inspired oxygen concentration is a major determinant of tissue oxygen tension,(23) which, in turn, is highly correlated with oxidative killing of bacteria by neutrophils over the range of observed values.(24) Oxidative killing is the major defense against surgical wound infection.”
BackgroundTramer, M. R., Reynolds, D. J. M., Moore, R. A., & McQuay, H. J. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00004 · Cited by 435
Rothen, H. U., Sporre, B., Engberg, G., Wegenius, G., Hogman, M., & Hedenstierna, G. (1995) · Anesthesiology · doi:10.1097/00000542-199504000-00004 · Cited by 363 · cited 2×
“High inspired oxygen concentrations—even for brief periods of time—have been shown to induce atelectasis.(7,8) The average amount of atelectasis in our patients was similar to that observed previously.”
BackgroundResultCofactor and substrate requirements of collagen proline hydroxylase
Hutton, J. J., Tappel, A. L., & Udenfriend, S. (1967) · Archives of Biochemistry and Biophysics · doi:10.1016/0003-9861(67)90302-5 · Cited by 307
Cited by
Supplemental Perioperative Oxygen to Reduce the Incidence of Surgical-Wound Infection
Greif, R., Akça, O., Horn, E.-P., Kurz, A., & Sessler, D. I. (2000) · New England Journal of Medicine · doi:10.1056/nejm200001203420303 · Cited by 1,159
Self-citationMeyhoff, C. S., Wetterslev, J., Jorgensen, L. N., Henneberg, S. W., Høgdall, C., Lundvall, L., Svendsen, P.-E., Mollerup, H., Lunn, T. H., Simonsen, I., et al. (2009) · JAMA · doi:10.1001/jama.2009.1452 · Cited by 418
Avoidance of Nitrous Oxide for Patients Undergoing Major Surgery: A Randomized Controlled Trial
Myles, P. S., Leslie, K., Chan, M. T. V., Forbes, A., Paech, M. J., Peyton, P., Silbert, B. S., & Pascoe, E. (2007) · Anesthesiology · doi:10.1097/01.anes.0000270723.30772.da · Cited by 412
Optimal Oxygen Concentration during Induction of General Anesthesia
Edmark, L., Kostova-Aherdan, K., Enlund, M., & Hedenstierna, G. (2003) · Anesthesiology · doi:10.1097/00000542-200301000-00008 · Cited by 411
Obesity Decreases Perioperative Tissue Oxygenation
Kabon, B., Nagele, A., Reddy, D., Eagon, C., Fleshman, J. W., Sessler, D. I., & Kurz, A. (2004) · Anesthesiology · doi:10.1097/00000542-200402000-00015 · Cited by 376
“Perioperative concentrations of oxygen restricted to 80% do not provoke atelectasis or other pulmonary dysfunction.(24) Therefore, available data suggest that it would be prudent to provide obese patients with an inspired oxygen concentration of at least 80% because the risk and cost are small, and doing so somewhat i…”
BackgroundSelf-citationAtelectasis and perioperative pulmonary complications in high-risk patients
Tusman, G., Böhm, S. H., Warner, D. O., & Sprung, J. (2012) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e32834dd1eb · Cited by 211
The Effect of Increased Fio2 Before Tracheal Extubation on Postoperative Atelectasis
Benoît, Z., Wicky, S., Fischer, J.-F., Frascarolo, P., Chapuis, C., Spahn, D. R., & Magnusson, L. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200212000-00058 · Cited by 193
“In one investigation (18), no difference was found in postoperative atelectasis in patients ventilated with 30% or 80% oxygen.”
BackgroundQadan, M. (2009) · Archives of Surgery · doi:10.1001/archsurg.2009.1 · Cited by 189
Hovaguimian, F., Lysakowski, C., Elia, N., & Tramèr, M. R. (2013) · Anesthesiology · doi:10.1097/aln.0b013e31829aaff4 · Cited by 176
Goll, V., Akça, O., Greif, R., Freitag, H., Arkiliç, C. F., Scheck, T., Zoeggeler, A., Kurz, A., Krieger, G., Lenhardt, R., et al. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200101000-00022 · Cited by 176
Self-citationThe effects of high perioperative inspiratory oxygen fraction for adult surgical patients
Wetterslev, J., Meyhoff, C. S., Jørgensen, L. N., Gluud, C., Lindschou, J., & Rasmussen, L. S. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008884.pub2 · Cited by 166
Oxygen and anesthesia: what lung do we deliver to the post‐operative ward?
HEDENSTIERNA, G. (2012) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2012.02689.x · Cited by 85
“The conclusion in one study that atelectasis was no larger by breathing 80% than 30% oxygen is not correct because anesthesia had been induced with conventional preoxygenation in all patients, when most of the atelectasis must have been produced.(57)”
BackgroundEffect of intraoperative hyperoxia on the incidence of surgical site infections: a meta-analysis
Cohen, B., Schacham, Y. N., Ruetzler, K., Ahuja, S., Yang, D., Mascha, E. J., Barclay, A. B., Hung, M. H., & Sessler, D. I. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.02.027 · Cited by 59
Self-citation
Metadata
- Authors
- Akça, O., Podolsky, A., Eisenhuber, E., Panzer, O., Hetz, H., Lampl, K., Lackner, F. X., Wittmann, K., Grabenwoeger, F., Kurz, A., Schultz, A.-M., Negishi, C., & Sessler, D. I.
- Venue
- Anesthesiology
- Published
- 1999-10-01
- Volume
- 91
- Issue
- 4
- Pages
- 991-991
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1996737049
- Cited by
- 173
- References
- 22
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.