Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 161

The DOI matches its Crossref record.

Electroencephalogram Approximate Entropy Correctly Classifies the Occurrence of Burst Suppression Pattern as Increasing Anesthetic Drug Effect

Open access
Bruhn, Jörgen, Röpcke, Heiko, Rehberg, Benno, Bouillon, Thomas, Hoeft, Andreas · 2000 · Anesthesiology

Abstract

Background: Approximate entropy, a measure of signal complexity and regularity, quantifies electroencephalogram changes during anesthesia. With increasing doses of anesthetics, burst-suppression patterns occur. Because of the high-frequency bursts, spectrally based parameters such as median electroencephalogram frequency and spectral edge frequency 95 do not decrease, incorrectly suggesting lightening of anesthesia. The authors investigated whether the approximate entropy algorithm correctly classifies the occurrence of burst suppression as deepening of anesthesia. Methods: Eleven female patients scheduled for elective major surgery were studied. After propofol induction, anesthesia was maintained with isoflurane only. Before surgery, the end-tidal isoflurane concentration was varied between 0.6 and 1.3 minimum alveolar concentration. The raw electroencephalogram was continuously recorded and sampled at 128 Hz. Approximate entropy, electroencephalogram median frequency, spectral edge frequency 95, burst-suppression ratio, and burst-compensated spectral edge frequency 95 were calculated offline from 8-s epochs. The relation between burst-suppression ratio and approximate entropy, electroencephalogram median frequency, spectral edge frequency 95, and burst-compensated spectral edge frequency 95 was analyzed using Pearson correlation coefficient. Results: Higher isoflurane concentrations were associated with higher burst-suppression ratios. Electroencephalogram median frequency (r = 0.34) and spectral edge frequency 95 (r = 0.29) increased, approximate entropy (r = -0.94) and burst-compensated spectral edge frequency 95 (r = -0.88) decreased with increasing burst-suppression ratio. Conclusion: Electroencephalogram approximate entropy, but not electroencephalogram median frequency or spectral edge frequency 95 without burst compensation, correctly classifies the occurrence of burst-suppression pattern as increasing anesthetic drug effect.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200010000-00018

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Bruhn, J., Röpcke, H., Rehberg, B., Bouillon, T., & Hoeft, A.
Venue
Anesthesiology
Published
2000-10-01
Volume
93
Issue
4
Pages
981-985
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1998850687
Cited by
161
References
0
FWCI
4.01
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electroencephalogram Approximate Entropy Correctly Classifies the Occurrence of Burst Suppression Pattern as Increasing Anesthetic Drug Effect. https://app.cochat.ai/papers/10.1097/00000542-200010000-00018
The paper
Bruhn, J., Röpcke, H., Rehberg, B., Bouillon, T., & Hoeft, A. (2000). Electroencephalogram Approximate Entropy Correctly Classifies the Occurrence of Burst Suppression Pattern as Increasing Anesthetic Drug Effect. Anesthesiology. https://doi.org/10.1097/00000542-200010000-00018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.