Randomized Study Comparing the “Sniffing Position” with Simple Head Extension for Laryngoscopic View in Elective Surgery Patients
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Background: The "sniffing position" is recommended for optimization of glottic visualization under direct laryngoscopy. However, no study to date has confirmed its superiority over simple head extension. In a prospective, randomized study, the authors compared the sniffing position with simple head extension in orotracheal intubation. Methods: The study included 456 consecutive patients. The sniffing position was obtained by placement of a 7-cm cushion under the head of the patient. The extension position was obtained by simple head extension. The anesthetic procedure included two Laryngoscopies without paralysis: the first was used for topical glottic anesthesia. During the second direct laryngoscopy, intubation of the trachea was performed. The head position was randomized as follows: group A was in the sniffing position during the first Laryngoscopy and the extension position during the second, group B was in the extension position during the first laryngoscopy and the sniffing position during the second. Glottic exposure was assessed by the Cormack scale. Results: The sniffing position improved glottic exposure (decreased the Cormack grade) in 18% of patients and worsened it (increased the Cormack grade) in 11% of patients, in comparison with simple extension. The Cormack grade distribution was not significantly modified between the two groups. Multivariate analysis showed that reduced neck mobility and obesity were independently related to improvement in laryngoscopic view with application of the sniffing position. Conclusions: Routine use of the sniffing position appears to provide no significant advantage over simple head extension for tracheal intubation in this setting. The sniffing position appears to be advantageous in obese and head extension-limited patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Difficult tracheal intubation in obstetrics
CORMACK, R. S., & LEHANE, J. (1984) · Anaesthesia · doi:10.1111/j.1365-2044.1984.tb08932.x · Cited by 2,471 · cited 3×
“This classification involves four grades of glottic visualization: grade 1 corresponds to complete visualization of the vocal cords, grade 2 to visualization of the inferior portion of the glottis, grade 3 to visualization of only the epiglottis, and grade 4 to a nonvisualized epiglottis.(9,11) The drawing of each gra…”
BackgroundMethodInfluentialA clinical sign to predict difficult tracheal intubation; a prospective study
Mallampati, S. R., Gatt, S. P., Gugino, L. D., Desai, S. P., Waraksa, B., Freiberger, D., & Liu, P. L. (1985) · Canadian Anaesthetists’ Society Journal · doi:10.1007/bf03011357 · Cited by 2,450
Difficult tracheal intubation: a retrospective study
SAMSOON, G. L. T., & YOUNG, J. R. B. (1987) · Anaesthesia · doi:10.1111/j.1365-2044.1987.tb04039.x · Cited by 1,584
PREDICTING DIFFICULT INTUBATION
WILSON, M. E., SPIEGELHALTER, D., ROBERTSON, J. A., & LESSER, P. (1988) · British Journal of Anaesthesia · doi:10.1093/bja/61.2.211 · Cited by 875
Adnet, F., Borron, S. W., Racine, S. X., Clemessy, J.-L., Fournier, J.-L., Plaisance, P., & Lapandry, C. (1997) · Anesthesiology · doi:10.1097/00000542-199712000-00005 · Cited by 703 · cited 1×
“Intubation difficulty was assessed by the Intubation Difficulty Scale (IDS).(12) This scale is based on the determination of seven parameters, recorded by an independent observer after each intubation: N1, the number of supplementary intubation attempts; N2, the number of supplementary operators; N3, the number of alt…”
MethodSelf-citationCasagrande, J. T., Pike, M. C., & Smith, P. G. (1978) · Biometrics · doi:10.2307/2530613 · Cited by 431 · cited 1×
“10 with the Casagrande and Pike formula.(13) With the assumption that use of the sniffing position might reduce the incidence of difficult laryngoscopy to approximately 837 RANDOMIZED STUDY OF THE “SNIFFING POSITION””
BackgroundThe Efficacy of the "BURP" Maneuver During a Difficult Laryngoscopy
Takahata, O., Kubota, M., Mamiya, K., Akama, Y., Nozaka, T., Matsumoto, H., & Ogawa, H. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199702000-00033 · Cited by 187 · cited 1×
“the same degree as laryngeal manipulation, a minimum of 222 patients for each group should be included.(14,15) Multiple logistic regression was used for analysis of the improvement (or worsening) of glottic visualization by the sniffing position maneuver (binary outcome, yes or no).”
MethodQuantitative improvement in laryngoscopic view by optimal external laryngeal manipulation
Benumof, J. L., & Cooper, S. D. (1996) · Journal of Clinical Anesthesia · doi:10.1016/0952-8180(95)00198-0 · Cited by 179 · cited 1×
“the same degree as laryngeal manipulation, a minimum of 222 patients for each group should be included.(14,15) Multiple logistic regression was used for analysis of the improvement (or worsening) of glottic visualization by the sniffing position maneuver (binary outcome, yes or no).”
MethodDifficult laryngoscopy: obtaining the best view
Benumof, J. L. (1994) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03009856 · Cited by 168 · cited 1×
“DIFFICULT laryngoscopy (as defined by poor glottic visualization) is synonymous with difficult intubation during surgery in the vast majority of patients.(1) Correct positioning of the patient appears to be the main determining factor for obtaining a good glottic visualization under direct laryngoscopy.”
BackgroundStudy of the “Sniffing Position” by Magnetic Resonance Imaging
Adnet, F., Borron, S. W., Dumas, J. L., Lapostolle, F., Cupa, M., & Lapandry, C. (2001) · Anesthesiology · doi:10.1097/00000542-200101000-00017 · Cited by 159
Self-citation
Cited by
Frerk, C., Mitchell, V. S., McNarry, A. F., Mendonca, C., Bhagrath, R., Patel, A., O’Sullivan, E. P., Woodall, N. M., & Ahmad, I. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev371 · Cited by 2,214
Laryngoscopic Intubation: Learning and Performance
Mulcaster, J. T., Mills, J., Hung, O. R., MacQuarrie, K., Law, J. A., Pytka, S., Imrie, D., & Field, C. (2003) · Anesthesiology · doi:10.1097/00000542-200301000-00007 · Cited by 355
The Importance of Increased Neck Circumference to Intubation Difficulties in Obese Patients
Gonzalez, H., Minville, V., Delanoue, K., Mazerolles, M., Concina, D., & Fourcade, O. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181679659 · Cited by 306
Law, J. A., Duggan, L. V., Asselin, M., Baker, P., Crosby, E., Downey, A., Hung, O. R., Kovacs, G., Lemay, F., Noppens, R., et al. (2021) · Canadian Journal of Anesthesia/Journal canadien d'anesthésie · doi:10.1007/s12630-021-02008-z · Cited by 203
Head and Neck Position for Direct Laryngoscopy
El-Orbany, M., Woehlck, H., & Salem, M. R. (2011) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31821c7e9c · Cited by 184
“In another recent study, 10 awake volunteers had MRI scans of the head placed in both the neutral and SP.10 Unlike the Adnet et al.16 study, a proper SP was verified by using the accepted end point (flexing the neck 35° and extending the head 15°).”
BackgroundResultInfluentialKim, W. H., Ahn, H. J., Lee, C. J., Shin, B. S., Ko, J. S., Choi, S. J., & Ryu, S. A. (2011) · British Journal of Anaesthesia · doi:10.1093/bja/aer024 · Cited by 180
Manoach, S., & Paladino, L. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2007.01.009 · Cited by 123
Metadata
- Authors
- Adnet, F., Baillard, C., Borron, S. W., Denantes, C., Lefebvre, L., Galinski, M., Martinez, C., Cupa, M., & Lapostolle, F.
- Venue
- Anesthesiology
- Published
- 2001-10-01
- Volume
- 95
- Issue
- 4
- Pages
- 836-841
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2156721496
- Cited by
- 218
- References
- 11
- FWCI
- 7.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.