The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Can Acceleromyography Detect Low Levels of Residual Paralysis?: A Probability Approach to Detect a Mechanomyographic Train-of-four Ratio of 0.9
Open accessAbstract
Background: The incidence of residual paralysis, i.e., a mechanomyographic train-of-four (TOF) ratio (T4/T1) less than 0.9, remains frequent. Routine acceleromyography has been proposed to detect residual paralysis in clinical practice. Although acceleromyographic data are easy to obtain, they differ from mechanomyographic data, with which they are not interchangeable. The current study aimed to determine (1) the acceleromyographic TOF ratio that detects residual paralysis with a 95% probability, and (2) the impact of calibration and normalization on this predictive acceleromyographic value. Methods: In 60 patients, recovery from neuromuscular block was assessed simultaneously with mechanomyography and acceleromyography. To obtain calibrated acceleromyographic TOF ratios in group A, the implemented calibration modus 2 was activated in the TOF-Watch S; to obtain uncalibrated acceleromyographic TOF ratios in group B, the current was manually set at 50 mA (n = 30 for each). In addition, data in group B were normalized (i.e., dividing the final TOF ratio by the baseline value). The agreement between mechanomyography and acceleromyography was assessed by calculating the intraclass correlation coefficient. Negative predictive values were calculated for detecting residual paralysis from acceleromyographic TOFs of 0.9, 0.95, and 1.0. Results: Group A: : For a mechanomyographic TOF of 0.9 or greater, the corresponding acceleromyographic TOF was 0.95 (range, 0.86-1.0), and the negative predictive values for acceleromyographic TOFs of 0.9, 0.95, and 1.0 were 37% (95% CI, 20-56%), 70% (95% CI, 51-85%), and 97% (95% CI, 83-100%), respectively. Group B: Without normalization, an acceleromyographic TOF of 0.97 (range, 0.68-1.18) corresponded to a mechanomyographic TOF of 0.9 or greater, with negative predictive values for acceleromyographic TOFs of 0.9, 0.95, and 1.0 being 40% (95% CI, 23-59%), 60% (95% CI, 41-77%), and 77% (95% CI, 58-90%), respectively. After normalization, an acceleromyographic TOF of 0.89 (range, 0.63-1.06) corresponded to a mechanomyographic TOF of 0.9 or greater, and the negative predictive values of acceleromyographic TOFs of 0.9, 0.95, and 1.0 were 89% (95% CI, 70-98%), 92% (95% CI, 75-99%), and 96% (95% CI, 80-100%), respectively. Conclusion: To exclude residual paralysis reliably when using acceleromyography, TOF recovery to 1.0 is mandatory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Cited by
Fuchs‐Buder, T., Claudius, C., Skovgaard, L. T., Eriksson, L. I., Mirakhur, R. K., & Viby‐Mogensen, J. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2007.01352.x · Cited by 606
Self-citationThilen, S. R., Weigel, W. A., Todd, M. M., Dutton, R. P., Lien, C. A., Grant, S. A., Szokol, J. W., Eriksson, L. I., Yaster, M., Grant, M. D., et al. (2023) · Anesthesiology · doi:10.1097/aln.0000000000004379 · Cited by 392
Kirmeier, E., Eriksson, L. I., Lewald, H., Jonsson Fagerlund, M., Hoeft, A., Hollmann, M., Meistelman, C., Hunter, J. M., Ulm, K., Blobner, M., et al. (2019) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(18)30294-7 · Cited by 372
Murphy, G. S., Szokol, J. W., Marymont, J. H., Greenberg, S. B., Avram, M. J., Vender, J. S., & Nisman, M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e318182af3b · Cited by 315
Brull, S. J., & Murphy, G. S. (2010) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181da8312 · Cited by 288
Metadata
- Authors
- Capron, F., Alla, F., Hottier, C., Meistelman, C., & Fuchs-Buder, T.
- Venue
- Anesthesiology
- Published
- 2004-05-01
- Volume
- 100
- Issue
- 5
- Pages
- 1119-1124
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2154969144
- Cited by
- 198
- References
- 1
- FWCI
- 7.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Can Acceleromyography Detect Low Levels of Residual Paralysis?: A Probability Approach to Detect a Mechanomyographic Train-of-four Ratio of 0.9. https://app.cochat.ai/papers/10.1097/00000542-200405000-00013
- The paper
- Capron, F., Alla, F., Hottier, C., Meistelman, C., & Fuchs-Buder, T. (2004). Can Acceleromyography Detect Low Levels of Residual Paralysis?: A Probability Approach to Detect a Mechanomyographic Train-of-four Ratio of 0.9. Anesthesiology. https://doi.org/10.1097/00000542-200405000-00013
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.