Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 216

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Trends but Not Individual Values of Central Venous Oxygen Saturation Agree with Mixed Venous Oxygen Saturation during Varying Hemodynamic Conditions

Dueck, Michael H., Klimek, Markus, Appenrodt, Stefan, Weigand, Christoph, Boerner, Ulf · 2005 · Anesthesiology

Abstract

Background: Previous studies found contradictory results regarding the question whether mixed venous oxygen saturation (Svo2) and central venous oxygen saturation (Scvo2) are equivalent. The inconsistency of study results may result from different study designs and different, partly questionable, statistical approaches. Methods: The authors performed a prospective clinical trial comparing individual oxygen saturation values as well as the trend of values in blood from the superior vena cava (Scvo2), the right atrium (Srao2), and the pulmonary artery (Svo2) during varying hemodynamic situations. The subjects were 70 patients scheduled to undergo elective neurosurgical operations in the sitting position. Oxygen saturation was measured photospectrometrically in blood samples simultaneously taken at four different time points during supine and sitting positions. Statistical analysis was performed following the recommendations of Bland and Altman. Results: Five hundred two comparative sets of measurements were obtained. Ninety-five percent limits of agreement ranging from +/-6.83 to +/-9.30% for single values were interpreted as clinically unacceptable. In contrast, correlations between changes of Svo2 and Scvo2 as well as of Svo2 and Srao2 were interpreted as clinically acceptable (R > or = 0.755, Pearson correlation coefficient; P < or = 0.0001). Conclusions: In this sample of patients, exact numerical values of Scvo2 and Srao2 are not equivalent to those of Svo2 in varying hemodynamic conditions. However, for clinical purposes, the trend of Scvo2 may be substituted for the trend of Svo2. In addition, previous studies investigating the agreement between Svo2 and Scvo2 were found to be lacking in their chosen statistical approaches.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-200508000-00007

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 216

Metadata

Authors
Dueck, M. H., Klimek, M., Appenrodt, S., Weigand, C., & Boerner, U.
Venue
Anesthesiology
Published
2005-08-01
Volume
103
Issue
2
Pages
249-257
ISSN
0003-3022 (ISSN-L)
OpenAlex
W2125443118
Cited by
216
References
4
FWCI
13.53
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Trends but Not Individual Values of Central Venous Oxygen Saturation Agree with Mixed Venous Oxygen Saturation during Varying Hemodynamic Conditions. https://app.cochat.ai/papers/10.1097/00000542-200508000-00007
The paper
Dueck, M. H., Klimek, M., Appenrodt, S., Weigand, C., & Boerner, U. (2005). Trends but Not Individual Values of Central Venous Oxygen Saturation Agree with Mixed Venous Oxygen Saturation during Varying Hemodynamic Conditions. Anesthesiology. https://doi.org/10.1097/00000542-200508000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.