Trends but Not Individual Values of Central Venous Oxygen Saturation Agree with Mixed Venous Oxygen Saturation during Varying Hemodynamic Conditions
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Background: Previous studies found contradictory results regarding the question whether mixed venous oxygen saturation (Svo2) and central venous oxygen saturation (Scvo2) are equivalent. The inconsistency of study results may result from different study designs and different, partly questionable, statistical approaches. Methods: The authors performed a prospective clinical trial comparing individual oxygen saturation values as well as the trend of values in blood from the superior vena cava (Scvo2), the right atrium (Srao2), and the pulmonary artery (Svo2) during varying hemodynamic situations. The subjects were 70 patients scheduled to undergo elective neurosurgical operations in the sitting position. Oxygen saturation was measured photospectrometrically in blood samples simultaneously taken at four different time points during supine and sitting positions. Statistical analysis was performed following the recommendations of Bland and Altman. Results: Five hundred two comparative sets of measurements were obtained. Ninety-five percent limits of agreement ranging from +/-6.83 to +/-9.30% for single values were interpreted as clinically unacceptable. In contrast, correlations between changes of Svo2 and Scvo2 as well as of Svo2 and Srao2 were interpreted as clinically acceptable (R > or = 0.755, Pearson correlation coefficient; P < or = 0.0001). Conclusions: In this sample of patients, exact numerical values of Scvo2 and Srao2 are not equivalent to those of Svo2 in varying hemodynamic conditions. However, for clinical purposes, the trend of Scvo2 may be substituted for the trend of Svo2. In addition, previous studies investigating the agreement between Svo2 and Scvo2 were found to be lacking in their chosen statistical approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743 · cited 3×
“In a recent study, Rivers et al.(33) significantly reduced mortality and organ dysfunction in patients with severe sepsis or septic shock using an early goal-directed Table 3.”
BackgroundMethodInfluentialMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Surviving Sepsis Campaign guidelines for management of severe sepsis and septic shock
Dellinger, R. P., Carlet, J. M., Masur, H., Gerlach, H., Calandra, T., Cohen, J., Gea-Banacloche, J., Keh, D., Marshall, J. C., Parker, M. M., et al. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2210-z · Cited by 3,321
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540110043030 · Cited by 2,210
Reinhart, K., Rudolph, T., Bredle, D. L., Hannemann, L., & Cain, S. M. (1989) · Chest · doi:10.1378/chest.95.6.1216 · Cited by 515 · cited 3×
“Continued Author Mean of Individual Differences (ScvO2 SvO2) (Bias) Correlation Coefficient of ScvO2 and SvO2 95% Limits of Agreement Change of Oxygen Saturation over Time (Trend) Authors’ Conclusion Ladakis et al.,7 2001 Yes Yes No No Individual SvO2 and ScvO2 values are interchangeable Reinhart et al.,11 2004 Yes Ye…”
MethodInfluentialContinuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill
Reinhart, K., Kuhn, H.-J., Hartog, C., & Bredle, D. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2337-y · Cited by 437 · cited 1×
“In a recent study, the same group could confirm these findings in critically ill patients.(11) Tahvanainen et al.”
ResultSedative and analgesic practice in the intensive care unit: the results of a European survey
Soliman, H. M., Mélot, C., & Vincent, J.-L. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.2.186 · Cited by 286
Central venous oxygen saturation monitoring in the critically ill patient
Rivers, E. P., Ander, D. S., & Powell, D. (2001) · Current Opinion in Critical Care · doi:10.1097/00075198-200106000-00011 · Cited by 242 · cited 2×
“Monitoring SvO2 is used as a clinical marker of systemic oxygen utilization in critically ill patients.(1) During sepsis, a redistribution of blood flow associated with a proportionally greater reduction in splenic, renal, and mesenteric blood flow may occur,(1,32) and in heart failure or circulatory shock, blood flow…”
MethodSCHEINMAN, M. M., BROWN, M. A., & RAPAPORT, E. (1969) · Circulation · doi:10.1161/01.cir.40.2.165 · Cited by 228
Lack of Equivalence Between Central and Mixed Venous Oxygen Saturation
Chawla, L. S., Zia, H., Gutierrez, G., Katz, N. M., Seneff, M. G., & Shah, M. (2004) · Chest · doi:10.1378/chest.126.6.1891 · Cited by 198
Barratt‐Boyes, B. G., & Wood, E. H. (1957) · PubMed · Cited by 175
Central Venous Oxygen Saturation in Shock: A Study in Man
Lee, J., Wright, F., Barber, R., & Stanley, L. (1972) · Anesthesiology · doi:10.1097/00000542-197205000-00012 · Cited by 165
Importance of the sampling site for measurement of mixed venous oxgen saturation in shock
Edwards, J. D., & Mayall, R. M. (1998) · Critical Care Medicine · doi:10.1097/00003246-199808000-00020 · Cited by 117
Martin, C. M. P., Auffray, J. P., Badetti, C., Perrin, G., Papazian, L., & Gouin, F. (1992) · Intensive Care Medicine · doi:10.1007/bf01705041 · Cited by 94 · cited 1×
“number of subjects ranged from 7(9) to 61,(7) and the number of comparative pairs of measurements ranged from 27(6) to 580.(9) In most studies, an unequal number of blood samples per subject was drawn, potentially resulting in an imbalanced statistical weight of subjects with exceedingly good or bad correspondences of…”
BackgroundGoal-Directed Therapy for Severe Sepsis
Abroug, F., Besbes, L., & Nouira, S. (2002) · New England Journal of Medicine · doi:10.1056/nejm200203283461314 · Cited by 42
Schou, H., Perez‐de‐Sá, V., & Larsson, A. (1998) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1998.tb05104.x · Cited by 31
Vincent, J. (1992) · Intensive Care Medicine · doi:10.1007/bf01694338 · Cited by 31
Central venous versus mixed venous oxygen content
FABER, T. (1995) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1995.tb04327.x · Cited by 26
Cited by
de Oliveira, C. F., de Oliveira, D. S. F., Gottschald, A. F. C., Moura, J. D. G., Costa, G. A., Ventura, A. C., Fernandes, J. C., Vaz, F. A. C., Carcillo, J. A., Rivers, E. P., et al. (2008) · Intensive Care Medicine · doi:10.1007/s00134-008-1085-9 · Cited by 400
Cecconi, M., Corredor, C., Arulkumaran, N., Abuella, G., Ball, J., Grounds, R. M., Hamilton, M., & Rhodes, A. (2012) · Critical Care · doi:10.1186/cc11823 · Cited by 339
Perioperative cardiovascular monitoring of high-risk patients: a consensus of 12
Vincent, J.-L., Pelosi, P., Pearse, R., Payen, D., Perel, A., Hoeft, A., Romagnoli, S., Ranieri, V. M., Ichai, C., Forget, P., et al. (2015) · Critical Care · doi:10.1186/s13054-015-0932-7 · Cited by 243
“Although the determinants of ScvO2 and SvO2 are similar, they cannot be used interchangeably [70-73].”
BackgroundMarino, B. S., Tabbutt, S., MacLaren, G., Hazinski, M. F., Adatia, I., Atkins, D. L., Checchia, P. A., DeCaen, A., Fink, E. L., Hoffman, G. M., et al. (2018) · Circulation · doi:10.1161/cir.0000000000000524 · Cited by 203
Cardiac output monitoring: an integrative perspective
Alhashemi, J. A., Cecconi, M., & Hofer, C. K. (2011) · Critical Care · doi:10.1186/cc9996 · Cited by 202
“It is important to realize that absolute ScvO2 and SvO2 values may diff er considerably in diff erent clinical situations; however, a strong correlation of their trends over time has been demonstrated [44].”
Background
Metadata
- Authors
- Dueck, M. H., Klimek, M., Appenrodt, S., Weigand, C., & Boerner, U.
- Venue
- Anesthesiology
- Published
- 2005-08-01
- Volume
- 103
- Issue
- 2
- Pages
- 249-257
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2125443118
- Cited by
- 216
- References
- 20
- FWCI
- 13.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.