Intraoperative Tidal Volume as a Risk Factor for Respiratory Failure after Pneumonectomy
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Background: Respiratory failure is a leading cause of postoperative morbidity and mortality in patients undergoing pneumonectomy. The authors hypothesized that intraoperative mechanical ventilation with large tidal volumes (VTs) would be associated with increased risk of postpneumonectomy respiratory failure. Methods: Patients undergoing elective pneumonectomy at the authors' institution from January 1999 to January 2003 were studied. The authors collected data on demographics, relevant comorbidities, neoadjuvant therapy, pulmonary function tests, site and type of operation, duration of surgery, intraoperative ventilator settings, and intraoperative fluid administration. The primary outcome measure was postoperative respiratory failure, defined as the need for continuation of mechanical ventilation for greater than 48 h postoperatively or the need for reinstitution of mechanical ventilation after extubation. Results: Of 170 pneumonectomy patients who met inclusion criteria, 30 (18%) developed postoperative respiratory failure. Causes of postoperative respiratory failure were acute lung injury in 50% (n = 15), cardiogenic pulmonary edema in 17% (n = 5), pneumonia in 23% (n = 7), bronchopleural fistula in 7% (n = 2), and pulmonary thromboembolism in 3% (n = 1). Patients who developed respiratory failure were ventilated with larger intraoperative VT than those who did not (median, 8.3 vs. 6.7 ml/kg predicted body weight; P < 0.001). In a multivariate regression analysis, larger intraoperative VT (odds ratio, 1.56 for each ml/kg increase; 95% confidence interval, 1.12-2.23) was associated with development of postoperative respiratory failure. The interaction between larger VT and fluid administration was also statistically significant (odds ratio, 1.36; 95% confidence interval, 1.05-1.97). Conclusion: Mechanical ventilation with large intraoperative VT is associated with increased risk of postpneumonectomy respiratory failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
CDC definitions for nosocomial infections, 1988
Garner, J. S., Jarvis, W. R., Emori, T. G., Horan, T. C., & Hughes, J. M. (1988) · American Journal of Infection Control · doi:10.1016/0196-6553(88)90053-3 · Cited by 5,672
Tremblay, L., Valenza, F., Ribeiro, S. P., Li, J., & Slutsky, A. S. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119259 · Cited by 1,330
Gajic, O., Dara, S. I., Mendez, J. L., Adesanya, A. O., Festic, E., Caples, S. M., Rana, R., St. Sauver, J. L., Lymp, J. F., Afessa, B., et al. (2004) · Critical Care Medicine · doi:10.1097/01.ccm.0000133019.52531.30 · Cited by 739
Self-citationParsons, P. E., Eisner, M. D., Thompson, B. T., Matthay, M. A., Ancukiewicz, M., Bernard, G. R., & Wheeler, A. P. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000149854.61192.dc · Cited by 723
Arozullah, A. M., Daley, J., Henderson, W. G., & Khuri, S. F. (2000) · Annals of Surgery · doi:10.1097/00000658-200008000-00015 · Cited by 700
Christopherson, R., Beattie, C., Frank, S. M., Norris, E. J., Meinert, C. L., Gottlieb, S. O., Yates, H., Rock, P., Parker, S. D., Perler, B. A., et al. (1993) · Anesthesiology · doi:10.1097/00000542-199309000-00004 · Cited by 532
Risk Factors for Acute Lung Injury After Thoracic Surgery for Lung Cancer
Licker, M., de Perrot, M., Spiliopoulos, A., Robert, J., Diaper, J., Chevalley, C., & Tschopp, J.-M. (2003) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000087799.85495.8a · Cited by 468
Pulmonary Complications Following Lung Resection
Steéphan, F., Boucheseiche, S., Hollande, J., Flahault, A., Cheffi, A., Bazelly, B., & Bonnet, F. (2000) · Chest · doi:10.1378/chest.118.5.1263 · Cited by 425
Gajic, O., Frutos-Vivar, F., Esteban, A., Hubmayr, R. D., & Anzueto, A. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2625-1 · Cited by 382
Self-citation
Cited by
Serpa Neto, A., Cardoso, S. O., Manetta, J. A., Pereira, V. G. M., Espósito, D. C., Pasqualucci, M. D. O. P., Damasceno, M. C. T., & Schultz, M. J. (2012) · JAMA · doi:10.1001/jama.2012.13730 · Cited by 843
Severgnini, P., Selmo, G., Lanza, C., Chiesa, A., Frigerio, A., Bacuzzi, A., Dionigi, G., Novario, R., Gregoretti, C., de Abreu, M. G., et al. (2013) · Anesthesiology · doi:10.1097/aln.0b013e31829102de · Cited by 474
Lohser, J., & Slinger, P. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000808 · Cited by 435
What Tidal Volumes Should Be Used in Patients without Acute Lung Injury?
Schultz, M. J., Haitsma, J. J., Slutsky, A. S., Gajic, O., & Warltier, D. C. (2007) · Anesthesiology · doi:10.1097/01.anes.0000267607.25011.e8 · Cited by 296
Self-citationLellouche, F., Dionne, S., Simard, S., Bussières, J., & Dagenais, F. (2012) · Anesthesiology · doi:10.1097/aln.0b013e3182522df5 · Cited by 283
Wolthuis, E. K., Choi, G., Dessing, M. C., Bresser, P., Lutter, R., Dzoljic, M., van der Poll, T., Vroom, M. B., Hollmann, M., & Schultz, M. J. (2008) · Anesthesiology · doi:10.1097/01.anes.0000296068.80921.10 · Cited by 272
Lung protective strategies in anaesthesia
Kilpatrick, B., & Slinger, P. (2010) · British Journal of Anaesthesia · doi:10.1093/bja/aeq299 · Cited by 238
Impact of intraoperative lung-protective interventions in patients undergoing lung cancer surgery
Licker, M., Diaper, J., Villiger, Y., Spiliopoulos, A., Licker, V., Robert, J., & Tschopp, J.-M. (2009) · Critical Care · doi:10.1186/cc7762 · Cited by 221
“Interestingly, a large tidal volume (VT) and an elevated inspiratory pressure during one-lung ventilation have been identified as strong predictors of ALI in two retrospective observational studies [9,10].”
BackgroundSchilling, T., Kozian, A., Senturk, M., Huth, C., Reinhold, A., Hedenstierna, G., & Hachenberg, T. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318214b9de · Cited by 214
Fernandez-Perez, E. R., Sprung, J., Afessa, B., Warner, D. O., Vachon, C. M., Schroeder, D. R., Brown, D. R., Hubmayr, R. D., & Gajic, O. (2009) · Thorax · doi:10.1136/thx.2008.102228 · Cited by 184
“the hips and knees, (6) cystectomies, (7) neurosurgical”
BackgroundSelf-citationManagement of One-lung Ventilation: Impact of Tidal Volume on Complications after Thoracic Surgery
Blank, R. S., Colquhoun, D. A., Durieux, M. E., Kozower, B. D., McMurry, T. L., Bender, S. P., & Naik, B. I. (2016) · Anesthesiology · doi:10.1097/aln.0000000000001100 · Cited by 177
Derivation and Diagnostic Accuracy of the Surgical Lung Injury Prediction Model
Kor, D. J., Warner, D. O., Alsara, A., Fernández-Pérez, E. R., Malinchoc, M., Kashyap, R., Li, G., & Gajic, O. (2011) · Anesthesiology · doi:10.1097/aln.0b013e31821b5839 · Cited by 176
Self-citationEvidence-based Management of One-Lung Ventilation
Lohser, J. (2008) · Anesthesiology Clinics · doi:10.1016/j.anclin.2008.01.011 · Cited by 175
“7 mL/kg) and larger fluid administration [67].”
Schilling, T., Kozian, A., Kretzschmar, M., Huth, C., Welte, T., Bühling, F., Hedenstierna, G., & Hachenberg, T. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem184 · Cited by 167
Metadata
- Authors
- Fernández-Pérez, E. R., Keegan, M. T., Brown, D. R., Hubmayr, R. D., & Gajic, O.
- Venue
- Anesthesiology
- Published
- 2006-07-01
- Volume
- 105
- Issue
- 1
- Pages
- 14-18
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1982773977
- Cited by
- 306
- References
- 20
- FWCI
- 14.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.