The Preclotting of Porous Arterial Prostheses
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A four-step preclotting method is presented for use with porous filamentous Dacron prostheses in the fully-heparinized patient. The method employs controlled fibrin formation within graft interstices, heparin neutralization of all thrombin remaining in the graft wall, and delay of systemic heparin neutralization until 15--20 minutes after clamp release. The resulting flow surface is impervious, smooth and hypothrombogenic. Experimental data are presented which support the rationale of this four-step preclotting method. Four years of clinical experience with the method are summarized, involving 300 prosthesis limbs used in aortic bifurcation, aortofemoral, femorofemoral, axillary-femoral and femoropopliteal positions in 192 patients. A clinical perspective of preclotting techniques is presented in which the proper use of this new method is suggested.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Purification and Mechanism of Action of Human Antithrombin-Heparin Cofactor
Rosenberg, R. D., & Damus, P. S. (1973) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(19)43472-8 · Cited by 1,356
THE USE OF TUBES CONSTRUCTED FROM VINYON “N” CLOTH IN BRIDGING ARTERIAL DEFECTS A PRELIMINARY REPORT
Voorhees, A. B., Jaretzki, A., & Blakemore, A. H. (1952) · Annals of Surgery · doi:10.1097/00000658-195203000-00006 · Cited by 569
Actions and Interactions of Antithrombin and Heparin
Bleich, H. L., Boro, E. S., & Rosenberg, R. D. (1975) · New England Journal of Medicine · doi:10.1056/nejm197501162920307 · Cited by 459
Interaction of thrombin and heparin. Proflavine dye binding studies
Li, E. H. H., Orton, C., & Feinman, R. D. (1974) · Biochemistry · doi:10.1021/bi00721a023 · Cited by 85
Interactions of synthetic and natural surfaces with blood in the physiological environment
Bruck, S. D. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110103 · Cited by 41
Cited by
Electrospinning collagen and elastin: preliminary vascular tissue engineering
Boland, E. (2004) · Frontiers in Bioscience · doi:10.2741/1313 · Cited by 537
Implantation of Vascular Grafts Lined with Genetically Modified Endothelial Cells
Wilson, J. M., Birinyi, L. K., Salomon, R. N., Libby, P., Callow, A. D., & Mulligan, R. C. (1989) · Science · doi:10.1126/science.2734614 · Cited by 337
Bhattacharya, V., McSweeney, P. A., Shi, Q., Bruno, B., Ishida, A., Nash, R., Storb, R. F., Sauvage, L. R., Hammond, W. P., & Wu, M. H.-D. (2000) · Blood · doi:10.1182/blood.v95.2.581 · Cited by 271
Self-citationRadke, D., Jia, W., Sharma, D., Fena, K., Wang, G., Goldman, J., & Zhao, F. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701461 · Cited by 256
Collagen-Based Tissue Engineering Strategies for Vascular Medicine
Copes, F., Pien, N., Van Vlierberghe, S., Boccafoschi, F., & Mantovani, D. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00166 · Cited by 203
Laroche, G., Marois, Y., Guidoin, R., King, M. W., Martin, L., How, T., & Douville, Y. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820291209 · Cited by 202
Metadata
- Authors
- YATES, S. G., BARROS DʼSA, A. A. B., BERGER, K., FERNANDEZ, L. G., WOOD, S. J., RITTENHOUSE, E. A., DAVIS, C. C., MANSFIELD, P. B., & SAUVAGE, L. R.
- Venue
- Annals of Surgery
- Published
- 1978-11
- Volume
- 188
- Issue
- 5
- Pages
- 611-622
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2075096412
- Cited by
- 185
- References
- 5
- FWCI
- 9.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.