Development of a Hybrid Bioartificial Liver
Open accessThe DOI matches its Crossref record.
Abstract
OBJECTIVE: The authors developed an extracorporeal liver support system and tested its efficacy in experimental animals with liver failure. The first clinical use of this system to treat a patient with liver failure is reported. SUMMARY BACKGROUND DATA: Multiple attempts have been made, ranging from plasma exchange to use of charcoal columns, to develop liver support systems for treating patients with acute severe liver failure. None of these systems has achieved wide clinical use. There is a need for providing liver support as a "bridge" to transplantation and for treating patients with potentially reversible liver dysfunction. METHODS: A hybrid liver support system has been developed consisting of plasma perfusion through a charcoal column and a porous hollow fiber module inoculated with 5 x 10(9) matrix-attached hepatocytes. The system was tested in dogs with ischemic liver failure (n = 7) who underwent plasmapheresis; a control group (n = 6) underwent charcoal perfusion alone. A patient with liver failure was treated with this hybrid system. RESULTS: After 6 hours of hybrid liver support treatment, animals had significantly decreased serum ammonia and lactate levels, increased glucose level, normal prothrombin time, and increased systolic blood pressure compared with controls treated with charcoal perfusion alone. Use of the system to treat a patient was well tolerated with evidence of clinical improvement. CONCLUSIONS: Plasma perfusion through a system consisting of a charcoal column and matrix-attached porcine hepatocytes had significant beneficial effects in animals with liver failure and was well tolerated by a patient with liver failure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Medical applications of membranes: Drug delivery, artificial organs and tissue engineering
Stamatialis, D. F., Papenburg, B. J., Gironés, M., Saiful, S., Bettahalli, S. N. M., Schmitmeier, S., & Wessling, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2007.09.059 · Cited by 473
“The HepatAssist system developed by irce Biomedical contains a hollow fiber bioreactor containing rimary porcine hepatocytes, two charcoal columns; membrane xygenator and a pump (Fig.”
BackgroundInfluentialWatanabe, F. D., Mullon, C. J.-P., Hewitt, W. R., Arkadopoulos, N., Kahaku, E., Eguchi, S., Khalili, T., Arnaout, W., Shackleton, C. R., Rozga, J., et al. (1997) · Annals of Surgery · doi:10.1097/00000658-199705000-00005 · Cited by 453
Self-citationA Review of Three-Dimensional In Vitro Tissue Models for Drug Discovery and Transport Studies
Elliott, N. T., & Yuan, F. (2011) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.22257 · Cited by 449
Cell and tissue engineering for liver disease
Bhatia, S. N., Underhill, G. H., Zaret, K. S., & Fox, I. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3005975 · Cited by 309
Clinical Application of Bioartificial Liver Support Systems
van de Kerkhove, M. P., Hoekstra, R., Chamuleau, R. A. F. M., & van Gulik, T. M. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000132986.75257.19 · Cited by 210
Metadata
- Authors
- Rozga, J., Holzman, M. D., Ro, M.-S., Griffin, D. W., Neuzil, D. F., Giorgio, T., Moscioni, A. D., & Demetriou, A. A.
- Venue
- Annals of Surgery
- Published
- 1993-05
- Volume
- 217
- Issue
- 5
- Pages
- 502-511
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2093661288
- Cited by
- 207
- References
- 0
- FWCI
- 14.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a Hybrid Bioartificial Liver. https://app.cochat.ai/papers/10.1097/00000658-199305010-00010
- The paper
- Rozga, J., Holzman, M. D., Ro, M.-S., Griffin, D. W., Neuzil, D. F., Giorgio, T., Moscioni, A. D., & Demetriou, A. A. (1993). Development of a Hybrid Bioartificial Liver. Annals of Surgery. https://doi.org/10.1097/00000658-199305010-00010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.