CoChat

Liquid Ventilation Improves Pulmonary Function, Gas Exchange, and Lung Injury in a Model of Respiratory Failure

Open access
Hirschl, Ronald B., Parent, Alan, Tooley, Richard, McCracken, Michael, Johnson, Kent, Shaffer, Thomas H., Wolfson, Marla R., Bartlett, Robert H. · 1995 · Annals of Surgery
Cited by 165

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The authors evaluated gas exchange, pulmonary function, and lung histology during perfluorocarbon liquid ventilation (LV) when compared with gas ventilation (GV) in the setting of severe respiratory failure. BACKGROUND: The efficacy of LV in the setting of respiratory failure has been evaluated in premature animals with surfactant deficiency. However, very little work has been performed in evaluating the efficacy of LV in older animal models of the adult respiratory distress syndrome (ARDS). METHODS: A stable model of lung injury was induced in 12 young sheep weighing 16.4 +/- 3.0 kg using right atrial injection of 0.07 mL/kg of oleic acid followed by saline pulmonary lavage and bijugular venovenous extracorporeal life support (ECLS). For the first 30 minutes on ECLS, all animals were ventilated with gas. Animals were then ventilated with either 15 mL/kg gas (GV, n = 6) or perflubron ([PFC], LV, n = 6) over the ensuing 2.5 hours. Subsequently, ECLS was discontinued in five of the GV animals and five of the LV animals, and GV or LV continued for 1 hour or until death. MAIN FINDINGS: Physiologic shunt (Qps/Qt) was significantly reduced in the LV animals when compared with the GV animals (LV = 31 +/- 10%; GV = 93 +/- 4%; p < 0.001) after 3 hours of ECLS. At the same time point, pulmonary compliance (CT) was significantly increased in the LV group when compared with the GV group (LV = 1.04 +/- 0.19 mL/cm H2O/kg; GV = 0.41 +/- 0.02 mL/cm H2O/kg; p < 0.001). In addition, the ECLS flow rate required to maintain the PaO2 in the 50- to 80-mm Hg range was substantially and significantly lower in the LV group when compared with that of the GV group (LV = 14 +/- 5 mL/kg/min; GV = 87 +/- 15 mL/kg/min; p < 0.001). All of the GV animals died after discontinuation of ECLS, whereas all the LV animals demonstrated effective gas exchange without extracorporeal support for 1 hour (p < 0.01). Lung biopsy light microscopy demonstrated a marked reduction in alveolar hemorrhage, lung fluid accumulation, and inflammatory infiltration in the LV group when compared with the GV animals. CONCLUSION: In a model of severe respiratory failure, LV improves pulmonary gas exchange and compliance with an associated reduction in alveolar hemorrhage, edema, and inflammatory infiltrate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000658-199501000-00010

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 165

Metadata

Authors
Hirschl, R. B., Parent, A., Tooley, R., McCracken, M., Johnson, K., Shaffer, T. H., Wolfson, M. R., & Bartlett, R. H.
Venue
Annals of Surgery
Published
1995-01
Volume
221
Issue
1
Pages
79-88
ISSN
0003-4932 (ISSN-L)
OpenAlex
W2003442522
Cited by
165
References
10
FWCI
19.68
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.