Telerobotic Laparoscopic Cholecystectomy: Initial Clinical Experience With 25 Patients
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine the safety and feasibility of performing telerobotic laparoscopic cholecystectomies. This will serve as a preliminary step toward the integration of computer-rendered three-dimensional preoperative imaging studies of anatomy and pathology onto the patient's own anatomy during surgery. SUMMARY BACKGROUND DATA: Computer-assisted surgery (CAS) increases the surgeon's dexterity and precision during minimally invasive surgery, especially when using microinstruments. Clinical trials have shown the improved microsurgical precision afforded by CAS in the minimally invasive setting in cardiac and gynecologic surgery. Future applications would allow integration of preoperative data and augmented-reality simulation onto the actual procedure. METHODS: Beginning in September 1999, CAS was used to perform cholecystectomies on 25 patients at a single medical center in this nonrandomized, prospective study. The operations were performed by one of two surgeons who had previous laboratory experience using the computer interface. The entire dissection was performed by the surgeon, who remained at a distance from the patient but in the same operating room. The operation was evaluated according to time of dissection, time of assembly/disassembly of robot, complications, immediate postoperative course, and short-term follow-up. RESULTS: Twenty of the 25 patients had symptomatic cholelithiasis, 1 had a gallbladder polyp, and 4 had acute cholecystitis. Twenty-four of the 25 laparoscopic cholecystectomies were successfully completed by CAS. There was one conversion to conventional laparoscopic cholecystectomy. Set-up and takedown of the robotic arms took a median of 18 minutes. The median operative time for dissection and the overall operative time were 25 and 108 minutes, respectively. There were no intraoperative complications. There was one postoperative complication of a suspected pulmonary embolus, which was treated with anticoagulation. All patients were tolerating diet at discharge. CONCLUSIONS: Laparoscopic cholecystectomy performed by CAS is safe and feasible, with operative times and patient recovery similar to those of conventional laparoscopy. At present, CAS cholecystectomy offers no obvious advantages to patients, but the potential advantages of CAS lie in its ability to convert the surgical act into digitized data. This digitized format can then interface with other forms of digitized data, such as pre- or intraoperative imaging studies, or be transmitted over a distance. This has the potential to revolutionize the way surgery is performed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanna, G. B., Shimi, S. M., & Cuschieri, A. (1998) · The Lancet · doi:10.1016/s0140-6736(97)08005-7 · Cited by 311
Telesurgical laparoscopic cholecystectomy
Himpens, J., Leman, G., & Cadiere, G. B. (1998) · Surgical Endoscopy · doi:10.1007/s004649900788 · Cited by 304
Computers and Virtual Reality for Surgical Education in the 21st Century
Haluck, R. S. (2000) · Archives of Surgery · doi:10.1001/archsurg.135.7.786 · Cited by 296
Virtual Reality Applied to Hepatic Surgery Simulation: The Next Revolution
Marescaux, J., Clément, J.-M., Tassetti, V., Koehl, C., Cotin, S., Russier, Y., Mutter, D., Delingette, H., & Ayache, N. (1998) · Annals of Surgery · doi:10.1097/00000658-199811000-00001 · Cited by 271
Self-citationInteractive image-guided neurosurgery
Galloway, R. L., Maciunas, R. J., & Edwards, C. A. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.184698 · Cited by 229
Interactive Image‐Guided Neurosurgery
(1995) · Journal of Neuroimaging · doi:10.1111/jon19955154b · Cited by 203
Automatic liver segmentation technique for three-dimensional visualization of CT data.
Gao, L., Heath, D. G., Kuszyk, B. S., & Fishman, E. K. (1996) · Radiology · doi:10.1148/radiology.201.2.8888223 · Cited by 177
Emerging Technologies for Surgery in the 21st Century
Satava, R. M. (1999) · Archives of Surgery · doi:10.1001/archsurg.134.11.1197 · Cited by 172
Full Robotic Assistance for Laparoscopic Tubal Anastomosis: A Case Report
Falcone, T., Goldberg, J. M., Ruíz, A., Margossian, H., & Stevens, L. (1999) · Journal of Laparoendoscopic & Advanced Surgical Techniques · doi:10.1089/lap.1999.9.107 · Cited by 168
Simulation and Virtual Reality in Surgical Education: Real or Unreal?
Gorman, P. J., Meier, A. H., & Krummel, T. M. (1999) · Archives of Surgery · doi:10.1001/archsurg.134.11.1203 · Cited by 162
Self-guided robotic camera control for laparoscopic surgery compared with human camera control
Omote, K., Feußner, H., Ungeheuer, A., Arbter, K., Wei, G.-Q., Siewert, J. R., & Hirzinger, G. (1999) · The American Journal of Surgery · doi:10.1016/s0002-9610(99)00055-0 · Cited by 150 · cited 1×
“In other studies, the ability of the computer-controlled endoscope to save positions increased the precision of the manipulations and decreased the time to return to a desired field of vision.(25) Further, the use of the robotics allowed the surgeon to remain in an ergonomically correct position throughout the procedu…”
BackgroundNeurosurgical robot Minerva: First results and current developments
Glauser, D., Fankhauser, H., Epitaux, M., Hefti, J. ‐., & Jaccottet, A. (1995) · Journal of Image Guided Surgery · doi:10.1002/(sici)1522-712x(1995)1:5<266::aid-igs2>3.0.co;2-8 · Cited by 135
Robotics and telemanipulation technologies for endoscopic surgery
Schurr, M. O., Bueß, G., Neisius, B., & Voges, U. (2000) · Surgical Endoscopy · doi:10.1007/s004640020067 · Cited by 131
The impact of external feedback on computer-assisted learning for surgical technical skill training
Rogers, D. A., Regehr, G., Howdieshell, T. R., Yeh, K. A., & Palm, E. (2000) · The American Journal of Surgery · doi:10.1016/s0002-9610(00)00341-x · Cited by 110
Robotically assisted microsurgery for endoscopic coronary artery bypass grafting
Stephenson, E. R., Sankholkar, S., Ducko, C. T., & Damiano, R. J. (1998) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(98)00656-0 · Cited by 105
7 3-D reconstruction of hepatic neoplasms: a preoperative planning procedure
van Leeuwen, M. S., Obertop, H., Hennipman, A., & Fernandez, M. A. (1995) · Baillière s Clinical Gastroenterology · doi:10.1016/0950-3528(95)90073-x · Cited by 11
Cited by
Robotic Surgery: A Current Perspective
Lanfranco, A. R., Castellanos, A. E., Desai, J. P., & Meyers, W. C. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000103020.19595.7d · Cited by 1,299
Transcontinental Robot-Assisted Remote Telesurgery: Feasibility and Potential Applications
Marescaux, J., Leroy, J., Rubino, F., Smith, M., Vix, M., Simone, M., & Mutter, D. (2002) · Annals of Surgery · doi:10.1097/00000658-200204000-00005 · Cited by 610
Self-citationHanly, E. J., & Talamini, M. A. (2004) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2004.08.020 · Cited by 332
Tactile Feedback Induces Reduced Grasping Force in Robot-Assisted Surgery
King, C.-H., Culjat, M. O., Franco, M. L., Lewis, C. E., Dutson, E. P., Grundfest, W. S., & Bisley, J. W. (2009) · IEEE Transactions on Haptics · doi:10.1109/toh.2009.4 · Cited by 224
“Thus, surgeons are physically isolated from the patient and must rely almost exclusively on visual cues [6], [7].”
BackgroundBreitenstein, S., Nocito, A., Puhan, M., Held, U., Weber, M., & Clavien, P.-A. (2008) · Annals of Surgery · doi:10.1097/sla.0b013e318172501f · Cited by 195
Metadata
- Authors
- Marescaux, J., Smith, M. K., Fölscher, D., Jamali, F., Malassagne, B., & Leroy, J.
- Venue
- Annals of Surgery
- Published
- 2001-07
- Volume
- 234
- Issue
- 1
- Pages
- 1-7
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2054855072
- Cited by
- 185
- References
- 16
- FWCI
- 22.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.