Prevention of Adhesion to Prosthetic Mesh: Comparison of Different Barriers Using an Incisional Hernia Model
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess whether use of antiadhesive liquids or coatings could prevent adhesion formation to prosthetic mesh. SUMMARY BACKGROUND DATA: Incisional hernia repair frequently involves the use of prosthetic mesh. However, concern exists about development of adhesions between viscera and the mesh, predisposing to intestinal obstruction or enterocutaneous fistulas. METHODS: In 91 rats, a defect in the muscular abdominal wall was created, and mesh was fixed intraperitoneally to cover the defect. Rats were divided in five groups: polypropylene mesh only (control group), addition of Sepracoat or Icodextrin solution to polypropylene mesh, Sepramesh (polypropylene mesh with Seprafilm coating), and Parietex composite mesh (polyester mesh with collagen coating). Seven and 30 days postoperatively, adhesions were assessed and wound healing was studied by microscopy. RESULTS: Intraperitoneal placement of polypropylene mesh was followed by bowel adhesions to the mesh in 50% of the cases. A mean of 74% of the mesh surface was covered by adhesions after 7 days, and 48% after 30 days. Administration of Sepracoat or Icodextrin solution had no influence on adhesion formation. Coated meshes (Sepramesh and Parietex composite mesh) had no bowel adhesions. Sepramesh was associated with a significant reduction of the mesh surface covered by adhesions after 7 and 30 days. Infection was more prevalent with Parietex composite mesh, with concurrent increased mesh surface covered by adhesions after 30 days (78%). CONCLUSIONS: Sepramesh significantly reduced mesh surface covered by adhesions and prevented bowel adhesion to the mesh. Parietex composite mesh prevented bowel adhesions as well but increased infection rates in the current model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comparison of suture repair with mesh repair for incisional hernia.
Luijendijk, R. W., Hop, W. C. J., van den Tol, M. P., de Lange, D. C. D., Braaksma, M. M. J., IJzermans, J. N. M., Boelhouwer, R. U., de Vries, B. C., Salu, M. K. M., Wereldsma, J. C. J., et al. (2000) · New England Journal of Medicine · doi:10.1056/nejm200008103430603 · Cited by 1,508 · cited 1×
“The reduction of recurrence rates following reinforcement of the abdominal wall by mesh in incisional hernia has promoted the use of mesh.(9) Polypropylene is most commonly used because it is easy to handle and relatively low in cost.”
BackgroundSelf-citationIncisional hernia: A 10 year prospective study of incidence and attitudes
Mudge, M., & Hughes, L. E. (1985) · Journal of British Surgery · doi:10.1002/bjs.1800720127 · Cited by 1,037
Ellis, H., Moran, B. J., Thompson, J. N., Parker, M. C., Wilson, M. S., Menzies, D., McGuire, A., Lower, A. M., Hawthorn, R. J., O'Brien, F., et al. (1999) · The Lancet · doi:10.1016/s0140-6736(98)09337-4 · Cited by 922
Long-term complications associated with prosthetic repair of incisional hernias
Leber, G. E. (1998) · Archives of Surgery · doi:10.1001/archsurg.133.4.378 · Cited by 714 · cited 2×
“A stronger inflammatory reaction with an increased incidence of infection and formation of enterocutaneous fistulas (16%) with the use of polyester mesh was also found in a clinical study by Leber et al.(11) In conclusion, Sepramesh significantly reduced adhesion formation and prevented bowel adhesion to the mesh in t…”
ResultSugerman, H. J., Kellum, J. M., Reines, H. D., DeMaria, E. J., Newsome, H. H., & Lowry, J. W. (1996) · The American Journal of Surgery · doi:10.1016/s0002-9610(99)80078-6 · Cited by 522
Diamond, M. P., & The Seprafilm Adhesion Study Group (1996) · Fertility and Sterility · doi:10.1016/s0015-0282(16)58716-0 · Cited by 457 · cited 1×
“Sepracoat persists at its site of application for only approximately 24 hours, while Seprafilm remains in place for at least 7 days.(28,31) Thus, intra-abdominal residence time might be an important factor and may have to exceed at least 7 days.”
BackgroundThe clinical significance of adhesions: focus on intestinal obstruction.
Ellis, H. (1997) · PubMed · Cited by 380
[Pathophysiology and classification of adhesions].
Zühlke, H. V., Lorenz, E. M., Straub, E. M., & Savvas, V. (1990) · PubMed · Cited by 266
Foreign Material in Postoperative Adhesions
Luijendijk, R. W., Lange, D., Wauters, C. C. A. P., Hop, W. C. J., Duron, J. J., Pailler, J. L., Camprodon, B. R., Holmdahl, L., van Geldorp, H. J., & Jeekel, J. (1996) · Annals of Surgery · doi:10.1097/00000658-199603000-00003 · Cited by 253
Self-citationUnacceptable results of the Mayo procedure for repair of abdominal incisional hernias
Paul, A., Korenkov, M., Peters, S., Köhler, L., Fischer, S., & Troidl, H. (2003) · European Journal of Surgery · doi:10.1080/110241598750004391 · Cited by 221
Adhesions: preventive strategies.
Risberg, B. (1997) · PubMed · Cited by 210
Diamond, M. P. (1998) · Fertility and Sterility · doi:10.1016/s0015-0282(98)00057-0 · Cited by 190
Hooker, G. D., Taylor, B. M., & Driman, D. K. (1999) · Surgery · doi:10.1016/s0039-6060(99)70267-9 · Cited by 167 · cited 4×
“and Hooker et al.(16) In all animals, laparotomy was performed using a midline incision of 4 cm.”
BackgroundMethodInfluentialA physiologic basis for the adhesion-free healing of deperitonealized surfaces
Buckman, R. F., Buckman, P. D., Hufnagel, H. V., & Gervin, A. S. (1976) · Journal of Surgical Research · doi:10.1016/0022-4804(76)90064-0 · Cited by 165 · cited 1×
“The fibrin matrix gradually matures into an organized fibrous adhesion over the course of approximately 5 days.(25) With time, the extent of adhesions decreases by approximately 30%, as was found in the present study (experiment 4 vs.”
Luijendijk, R. W., Lemmen, M. H. M., Hop, W. C. J., & Wereldsma, J. C. J. (1997) · World Journal of Surgery · doi:10.1007/s002689900194 · Cited by 150
Verco, S. J. S. (2000) · Human Reproduction · doi:10.1093/humrep/15.8.1764 · Cited by 128 · cited 1×
“reported fewer adhesions after administration of Icodextrin in a uterine horn model in rabbits.(30) In the rat, the intraabdominal amylase concentration is higher than in the rabbit, which may lead to a shorter intraperitoneal residence time of Icodextrin in the rat.”
BackgroundAdhesion formation and peritoneal healing on prosthetic materials
Law, N. W., & Ellis, H. (1988) · Clinical Materials · doi:10.1016/0267-6605(88)90014-5 · Cited by 104
Seprafilm reduces adhesions to polypropylene mesh
Baptista, M. L., Bonsack, M. E., & Delaney, J. P. (2000) · Surgery · doi:10.1067/msy.2000.106810 · Cited by 102
Alponat, A., Lakshminarasappa, S. R., Yavuz, N., & Goh, P. M. Y. (1997) · PubMed · Cited by 98
Fibrinolytic activity of mesothelial surfaces.
Porter, J. M., Fh, M., Mullen, D. C., & Silver, D. (1969) · PubMed · Cited by 74
Evaluation of resorbable barriers for preventing surgical adhesions
Arnold, P. B., Green, C. W., Foresman, P. A., & Rodeheaver, G. T. (2000) · Fertility and Sterility · doi:10.1016/s0015-0282(99)00464-1 · Cited by 71 · cited 1×
“In a rat and rabbit model, a bioresorbable membrane of hyaluronate and carboxymethylcellulose (Seprafilm) has been reported to diminish adhesion formation significantly.(15,16,18,32) However, this membrane is not applicable in laparoscopic incisional hernia repair because of technical difficulties with the introductio…”
BackgroundRole of fibrinolysis in the formation of postoperative adhesions
Holmdahl, L., Al-Jabreen, M., & Risberg, B. (1994) · Wound Repair and Regeneration · doi:10.1046/j.1524-475x.1994.20306.x · Cited by 65 · cited 1×
“This inhibition is followed by reduced fibrinolysis, which results in increased deposition of fibrin matrix.(23,24) The fibrin matrix gradually matures into an organized fibrous adhesion over the course of approximately 5 days.”
Background
Cited by
Breuing, K., Butler, C. E., Ferzoco, S., Franz, M., Hultman, C. S., Kilbridge, J. F., Rosen, M., Silverman, R. P., & Vargo, D. (2010) · Surgery · doi:10.1016/j.surg.2010.01.008 · Cited by 1,031
The open abdomen in trauma and non-trauma patients: WSES guidelines
Coccolini, F., Roberts, D., Ansaloni, L., Ivatury, R., Gamberini, E., Kluger, Y., Moore, E. E., Coimbra, R., Kirkpatrick, A. W., Pereira, B. M., et al. (2018) · World Journal of Emergency Surgery · doi:10.1186/s13017-018-0167-4 · Cited by 354
Past, Present and Future of Surgical Meshes: A Review
Baylón, K., Rodríguez-Camarillo, P., Elías-Zúñiga, A., Díaz-Elizondo, J., Gilkerson, R., & Lozano, K. (2017) · Membranes · doi:10.3390/membranes7030047 · Cited by 292
Butler, C. E., Langstein, H. N., & Kronowitz, S. J. (2005) · Plastic and Reconstructive Surgery · doi:10.1097/01.prs.0000181692.71901.bd · Cited by 264
Abdominal adhesions: Current and novel therapies
Ward, B. C., & Panitch, A. (2011) · Journal of Surgical Research · doi:10.1016/j.jss.2009.09.015 · Cited by 249
Metadata
- Authors
- van ’t Riet, M., de Vos van Steenwijk, P. J., Bonthuis, F., Marquet, R. L., Steyerberg, E. W., Jeekel, J., & Bonjer, H. J.
- Venue
- Annals of Surgery
- Published
- 2003-01
- Volume
- 237
- Issue
- 1
- Pages
- 123-128
- ISSN
- 0003-4932 (ISSN-L)
- OpenAlex
- W2055428093
- Cited by
- 200
- References
- 22
- FWCI
- 9.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.