The DOI matches its Crossref record.
Use of Medpor Porous Polyethylene Implants in 140 Patients with Facial Fractures
Abstract
Use of alloplastic materials in facial bone reconstruction is still controversial. Medpor porous polyethylene is a relatively new implant material that is well suited for this purpose and has a number of advantages over other alloplasts. It is a pure polyethylene with a unique manufacturing process and pore size. Technically, it is easy to work with; it can be carved, contoured, adapted, and fixated to obtain a precise three-dimensional construct. Physically, it is a pure, biocompatible, strong substance that does not resorb or degenerate. It demonstrates long-term stability, high tensile strength, resistance to stress and fatigue, and a virtual lack of surrounding soft-tissue reaction. Rapid tissue ingrowth occurs into the pores. Extensive vascular ingrowth creates the potential to transport cellular products that fight infection deep into the implant. The implant was used in 140 patients from June 1988 to August 1991 to treat acute orbitozygomatic injuries (71), acute Le Fort injuries (24), delayed orbitozygomatic injuries (33), and delayed onlay augmentation (12). In this series, there was 1 instance of implant infection requiring removal, and no implant migration, or exposure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rubin, P. J., & Yaremchuk, M. J. (1997) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199710000-00043 · Cited by 328
Craniofacial reconstruction with high-density porous polyethylene implants.
Menderes, A., Baytekin, C., Topcu, A., Yilmaz, M., & Barutcu, A. (2004) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200409000-00004 · Cited by 90
Aesthetic microtia reconstruction with Medpor
Romo, T., & Reitzen, S. (2008) · Facial Plastic Surgery · doi:10.1055/s-2008-1037453 · Cited by 86
Metadata
- Authors
- Romano, J. J., IIiff, N. T., & Manson, P. N.
- Venue
- Journal of Craniofacial Surgery
- Published
- 1993-07
- Volume
- 4
- Issue
- 3
- Pages
- 142-147
- ISSN
- 1049-2275 (ISSN-L)
- OpenAlex
- W2077869860
- Cited by
- 210
- References
- 0
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of Medpor Porous Polyethylene Implants in 140 Patients with Facial Fractures. https://app.cochat.ai/papers/10.1097/00001665-199307000-00007
- The paper
- Romano, J. J., IIiff, N. T., & Manson, P. N. (1993). Use of Medpor Porous Polyethylene Implants in 140 Patients with Facial Fractures. Journal of Craniofacial Surgery. https://doi.org/10.1097/00001665-199307000-00007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.