The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Complications and Toxicities of Implantable Biomaterials Used in Facial Reconstructive and Aesthetic Surgery: A Comprehensive Review of the Literature
Abstract
The use of implantable biomaterials has become an integral part of aesthetic and reconstructive surgery of the face. Metals are used for fracture fixation devices, whereas polymers are used primarily for bone or soft-tissue substitution. This review of the scientific literature examines the risks and complications of these materials. First, we present an overview of commonly used materials. Second, we address general considerations of toxicity relevant to all biomaterials. Third, we present data from a large number of clinical series on the incidence of complications for individual materials used in specific applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mandibular osteosynthesis by miniature screwed plates via a buccal approach
Champy, M., Loddé, J. P., Schmitt, R., Jaeger, J. H., & Muster, D. (1978) · Journal of Maxillofacial Surgery · doi:10.1016/s0301-0503(78)80062-9 · Cited by 874
Late degradation tissue response to poly(?-lactide) bone plates and screws
Bergsma, J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91092-d · Cited by 799
Bergsma, E. J., Rozema, F. R., Bos, R. R. M., & Bruijn, W. C. D. (1993) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(10)80267-8 · Cited by 541
Absorbable implants for the fixation of fractures.
Böstman, O. M. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173010-00022 · Cited by 459
Resorbable poly(L-lactide) plates and screws for the fixation of zygomatic fractures
Bos, R. R. M., Boering, G., Rozema, F. R., & Leenslag, J. W. (1987) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/0278-2391(87)90194-7 · Cited by 324
An evaluation of bone growth into porous high density polyethylene
Klawitter, J. J., Bagwell, J. G., Weinstein, A. M., Sauer, B. W., & Pruitt, J. R. (1976) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820100212 · Cited by 312
The incidence of cancer following total hip replacement
Gillespie, W., Frampton, C., Henderson, R., & Ryan, P. (1988) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.70b4.3403594 · Cited by 222
Use of Medpor Porous Polyethylene Implants in 140 Patients with Facial Fractures
Romano, J. J., IIiff, N. T., & Manson, P. N. (1993) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199307000-00007 · Cited by 210
Orbital Reconstruction Using Porous Polyethylene Sheets
Rubin, P. A. D., Bilyk, J. R., & Shore, J. W. (1994) · Ophthalmology · doi:10.1016/s0161-6420(94)31113-4 · Cited by 199
Self-citationTreatment outcomes for temporomandibular joint reconstruction after Proplast-Teflon implant failure
Henry, C. H., & Wolford, L. M. (1993) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(10)80343-x · Cited by 193
Cited by
Porosity of 3D biomaterial scaffolds and osteogenesis
Karageorgiou, V., & Kaplan, D. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.02.002 · Cited by 6,622
Navarro, M., Michiardi, A., Castaño, O., & Planell, J. A. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0151 · Cited by 1,513
Osteoinduction of bone grafting materials for bone repair and regeneration
García-Gareta, E., Coathup, M. J., & Blunn, G. W. (2015) · Bone · doi:10.1016/j.bone.2015.07.007 · Cited by 649
In situ bioprinting – Bioprinting from benchside to bedside?
Singh, S., Choudhury, D., Yu, F., Mironov, V., & Naing, M. W. (2020) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.08.045 · Cited by 273
Craniofacial reconstruction with high-density porous polyethylene implants.
Menderes, A., Baytekin, C., Topcu, A., Yilmaz, M., & Barutcu, A. (2004) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200409000-00004 · Cited by 90
Metadata
- Authors
- Rubin, P. J., & Yaremchuk, M. J.
- Venue
- Plastic and Reconstructive Surgery
- Published
- 1997-10
- Volume
- 100
- Issue
- 5
- Pages
- 1336-1353
- ISSN
- 0032-1052 (ISSN-L)
- OpenAlex
- W2089508440
- Cited by
- 328
- References
- 25
- FWCI
- 3.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Complications and Toxicities of Implantable Biomaterials Used in Facial Reconstructive and Aesthetic Surgery: A Comprehensive Review of the Literature. https://app.cochat.ai/papers/10.1097/00006534-199710000-00043
- The paper
- Rubin, P. J., & Yaremchuk, M. J. (1997). Complications and Toxicities of Implantable Biomaterials Used in Facial Reconstructive and Aesthetic Surgery: A Comprehensive Review of the Literature. Plastic and Reconstructive Surgery. https://doi.org/10.1097/00006534-199710000-00043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.