The Influence of Temperature on the Degradation Rate of LactoSorb Copolymer
The DOI matches its Crossref record; 45 of the 46 references it cites were found in a registry or an index, and 1 are not checked yet.
Abstract
Heat is one of the fundamental forces that influence the rates of chemical reactions. The hydrolysis of an absorbable polymer is a function of many factors, both material-related and implant-site-related, including temperature. There is variance in temperature among patients as well as among various animals in which degradation studies are performed. This study investigated the influence of temperature on hydrolysis and found that a variance from 37 degrees C to as little as 2 degrees C can affect the rate of hydrolysis of a PGA/PLLA copolymer about 25-30%, with the rate increasing with increasing temperature. As most animals of biomedical interest have a body temperature on the order of 1-3 degrees C greater than that of humans, it is possible that animal testing may be "worst case"; that is, strength loss may be accelerated in animals relative to that in human patients. Also, variation of body temperature within the human population may contribute to some variance in the rate of hydrolysis from person to person; however, other influences may minimize this effect and make it difficult to observe clinically.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, body temperature varies significantly between human and certain animals such as pigs and rabbits (approximately 1-3 °C higher than humans) which are commonly used as in vivo models [34].”
From In vitro degradation and mechanical properties of PLA-PCL copolymer unit cell scaffolds generated by two-photon polymerization (2016) · cites this paper as [34]
In the citing paper
“Relating accelerated degradation at elevated temperatures to 37 °C allows effective fast screening rather than long term studies saving research funds and time [34].”
From In vitro degradation and mechanical properties of PLA-PCL copolymer unit cell scaffolds generated by two-photon polymerization (2016) · cites this paper as [34]
In the citing paper
“The values of activation energy obtained for LC scaffolds using rate of mass loss were similar to the published results for biodegradable polymers [34,40,71].”
From In vitro degradation and mechanical properties of PLA-PCL copolymer unit cell scaffolds generated by two-photon polymerization (2016) · cites this paper as [34]
In the citing paper
“Arrhenius relation has been conducted for the change in several parameters of biodegradable polymers such as molecular weight, breaking strength, viscosity and mass loss [34,38,49,71,72].”
From In vitro degradation and mechanical properties of PLA-PCL copolymer unit cell scaffolds generated by two-photon polymerization (2016) · cites this paper as [34]
In the citing paper
“Pietrzak et al [34] applied the Arrhenius equation to change in inherent viscosity for a 82%PLLA-18%PGA copolymer and obtained an activation energy of 100.1 kJ”
From In vitro degradation and mechanical properties of PLA-PCL copolymer unit cell scaffolds generated by two-photon polymerization (2016) · cites this paper as [34]
Citations
Cites
Li, S. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:3<246::aid-jbm7>3.0.co;2-x · Cited by 671
Li, S. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(1999)48:3<342::aid-jbm20>3.0.co;2-7 · Cited by 664
Fundamental principles of polymeric materials
(2012) · Choice Reviews Online · doi:10.5860/choice.50-2091 · Cited by 492
Post-traumatic contracture of the elbow. Operative treatment, including distraction arthroplasty.
Morrey, B. F. (1990) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199072040-00019 · Cited by 491
Orthopaedic applications for PLA‐PGA biodegradable polymers
Athanasiou, K., Agrawal, C., Barber, F., & Burkhart, S. (1998) · Arthroscopy · doi:10.1016/s0749-8063(98)70099-4 · Cited by 487
Tonino, A., Davidson, C., Klopper, P., & Linclau, L. (1976) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.58b1.1270486 · Cited by 338
Polylactide. II. Viscosity–molecular weight relationships and unperturbed chain dimensions
Schindler, A., & Harper, D. (1979) · Journal of Polymer Science: Polymer Chemistry Edition · doi:10.1002/pol.1979.170170831 · Cited by 278
Bergsma, J. E., Rozema, F. R., Bos, R. R. M., Boering, G., de Bruijn, W. C., & Pennings, A. J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93253-a · Cited by 247
Bioabsorbable Polymer Science for the Practicing Surgeon
Pietrzak, W. S., Sarver, D. R., & Verstynen, M. L. (1997) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199703000-00004 · Cited by 185
Self-citationAbsorbable polyglycolide devices in trauma and bone surgery
Ashammakhi, N., & Rokkanen, P. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00107-x · Cited by 166
Polyethylene wear in total hip and knee arthroplasties.
Lewis, G. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199721)38:1<17::aid-jbm3>3.0.co;2-k · Cited by 163
Degradation Characteristics of PLLA-PGA Bone Fixation Devices
Eppley, B. L., & Reilly, M. (1997) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199703000-00010 · Cited by 156
Self-citationRemoval of forearm plates. A review of the complications
Langkamer, V. G., & Ackroyd, C. E. (1990) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.72b4.2380210 · Cited by 137
Apatite formation on organic monolayers in simulated body environment
Sato, K., Kumagai, Y., & Tanaka, J. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(200004)50:1<16::aid-jbm3>3.0.co;2-g · Cited by 124
Elevated temperature degradation of a 50:50 copolymer of PLA-PGA
Agrawal, C. M., Huang, D., Schmitz, J. P., & Athanasiou, K. A. (1997) · Tissue Engineering · doi:10.1089/ten.1997.3.345 · Cited by 120 · cited 3×
“Agrawal et al.24 mathematically modeled the temperature dependence of a 50:50 poly(lactic acid):poly(glycolic acid) copolymer over a wide temperature range (25–80°C); however, there was no attempt to interpret the results in clinical terms.”
BackgroundMethodvan der Elst, M., Klein, C. P. A. T., Hogervorst, J. M. A., Patka, P., & Haarman, H. J. T. M. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00117-3 · Cited by 109
Nonmetallic Fixation in Traumatic Midfacial Fractures
Eppley, B. L., & Prevel, C. D. (1997) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199703000-00008 · Cited by 98
Self-citationReasons for Removal of Rigid Internal Fixation Devices in Craniofacial Surgery
Orringer, J. S., Barcelona, V., & Buchman, S. R. (1998) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199801000-00009 · Cited by 97
Viljanen, J., Kinnunen, J., Bondestam, S., Majola, A., Rokkanen, P., & Törmälä, P. O. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91052-z · Cited by 97
Early Experience With Biodegradable Fixation for Congenital Pediatric Craniofacial Surgery
Goldstein, J. A., Quereshy, F. A., & Cohen, A. R. (1997) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199703000-00009 · Cited by 74
Craniofacial Skeletal Fixation Using Biodegradable Plates and Cyanoacrylate Glue
Ahn, D. K., Sims, D. C., Randolph, M. A., O'Connor, D., Butler, P. E. M., Amarante, M. T. J., & Yaremchuk, M. J. (1997) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199705010-00005 · Cited by 73
Simon, J. A., Ricci, J. L., & Cesare, P. E. D. (1997) · PubMed · Cited by 61
Effects of Anatomic Site, Oral Stimulation, and Body Position on Estimates of Body Temperature
Rabinowitz, R. P., Cookson, S. T., Wasserman, S. S., & Mackowiak, P. A. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.1996.00440070107012 · Cited by 53
Key Points in the Fixation of the Craniofacial Skeleton with Absorbable Biomaterial
Habal, M. B., & Pietrzak, W. S. (1999) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199911000-00008 · Cited by 52
Self-citationResorbable PLLA-PGA Screw Fixation of Mandibular Sagittal Split Osteotomies
Edwards, R. C., Kiely, K. D., & Eppley, B. L. (1999) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199905000-00011 · Cited by 50
Self-citationUse of a Resorbable Fixation Technique for Maxillary Fractures
Eppley, B. L. (1998) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199807000-00005 · Cited by 48
Self-citationHuman body temperature is inversely correlated with body mass
Adam, K. (1989) · European Journal of Applied Physiology · doi:10.1007/bf02330699 · Cited by 47
Fixation of Osteotomies Using Bioabsorbable Screws in the Canine Femur
An, Y. H., Friedman, R. J., Powers, D. L., Draughn, R. A., & Latour, R. A. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810000-00032 · Cited by 45
Body temperature in general population samples. The study of men born in 1913 and 1923.
Eriksson, H., Svärdsudd, K., Larsson, B., Welin, L., Ohlson, L. ‐., & Wilhelmsen, L. (1985) · PubMed · Cited by 42
Resorbable polyesters: composition, properties, applications.
Amecke, B., Bendix, D., & Entenmann, G. (1992) · Clinical Materials · doi:10.1016/0267-6605(92)90084-7 · Cited by 42
Absorbable, Invisible, and Flexible Plating System for the Craniofacial Skeleton
Habal, M. B. (1997) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199703000-00011 · Cited by 42
Resorbable Coupling Fixation in Craniosynostosis Surgery: Experimental and Clinical Applications
Eppley, B. L., & Sadove, A. M. (1995) · Journal of Craniofacial Surgery · doi:10.1097/00001665-199511000-00011 · Cited by 41
Self-citationBody Temperature in General Population Samples: The Study of Men Born in 1913 and 1923
ERIKSSON, H., SVÅRDSUDD, K., LARSSON, B., WELIN, L., OHLSON, L., & WILHELMSEN, L. (1985) · Acta Medica Scandinavica · doi:10.1111/j.0954-6820.1985.tb02708.x · Cited by 41
The effects of small plate osteosynthesis on postoperative radiotherapy
Postlethwaite, K. R., Philips, J. G., Booth, S. A., Shaw, J., & Slater, A. J. (1989) · British Journal of Oral and Maxillofacial Surgery · doi:10.1016/0266-4356(89)90076-4 · Cited by 38
Tissue Reaction to Implant Corrosion in 38 Internal Fixation Devices
Thomas, K. A., Cook, S. D., Harding, A. F., & Haddad, R. J. (1988) · Orthopedics · doi:10.3928/0147-7447-19880301-09 · Cited by 37
Background of the Early Development of Absorbable Fixation Devices
Viljanen, V. V., & Lindholm, T. S. (1998) · Techniques in Orthopaedics · doi:10.1097/00013611-199806000-00004 · Cited by 27
Critical Concepts of Absorbable Internal Fixation
Pietrzak, W. S. (2000) · Journal of Craniofacial Surgery · doi:10.1097/00001665-200011040-00011 · Cited by 21
Self-citationThe effect of site of implantation and animal age on properties of polydioxanone pins
Bhatia, S., Shalaby, S. W., Powers, D. L., Lancaster, R. L., & Ferguson, R. L. (1995) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856294x00428 · Cited by 20
Local Tissue of the Lumbar Spine Response to Titanium Plate-Screw System
Xu, R., Ebraheim, N. A., Nadaud, M. C., & Phillips, E. R. (1996) · Spine · doi:10.1097/00007632-199604010-00020 · Cited by 20
Oral Temperature Range in Old Age
Howell, T. H. (2009) · Gerontologia Clinica · doi:10.1159/000245569 · Cited by 18
Particulate retrieval of hydrolytically degraded poly(lactide-co-glycolide) polymers
Cordewener, F. W., Dijkgraaf, L. C., Ong, J. L., Agrawal, C. M., Zardeneta, G., Milam, S. B., & Schmitz, J. P. (2000) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(200004)50:1<59::aid-jbm9>3.0.co;2-m · Cited by 16
Powers, D. L., Sonawala, M., Woolf, S. K., An, Y. H., Hawkins, R. J., & Pietrzak, W. S. (2001) · Journal of Biomedical Materials Research · doi:10.1002/jbm.1045 · Cited by 13
Self-citationFatigue Testing of Bioabsorbable Screws in a Synthetic Bone Substrate
Pietrzak, W. S., Sarver, D. R., & Kohn, D. H. (1999) · CRC Press eBooks · doi:10.1201/9781420073560-47 · Cited by 7
Self-citationSchwartz, H. C. (1990) · British Journal of Oral and Maxillofacial Surgery · doi:10.1016/0266-4356(90)90020-l · Cited by 4
Chemical kinetics and chemical equilibrium
MACKIN, M. H. (1982) · Elsevier eBooks · doi:10.1016/b978-0-12-705961-7.50019-5 · Cited by 3
Roth, D. A., Gosain, A. K., McCarthy, J. G., et al. (1997) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199705000-00005
Research works printed but not linked: 5
Cited by
Degradation Behavior of Polymers Used as Coating Materials for Drug Delivery—A Basic Review
Visan, A. I., Popescu-Pelin, G., & Socol, G. (2021) · Polymers · doi:10.3390/polym13081272 · Cited by 161
“TEMPERATURE and Tg PGA/PLLA, PLGA copolymer [158,159]”
Tissue response to partially in vitro predegraded poly-L-lactide implants
de Jong, W. H., Bergsma, J. E., Robinson, J. E., & Bos, R. R. M. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.06.026 · Cited by 117
Larsen, M. W., Pietrzak, W. S., & DeLee, J. C. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504265927 · Cited by 112
Self-citationFelfel, R. M., Poocza, L., Gimeno-Fabra, M., Milde, T., Hildebrand, G., Ahmed, I., Scotchford, C., Sottile, V., Grant, D. M., & Liefeith, K. (2016) · Biomedical Materials · doi:10.1088/1748-6041/11/1/015011 · Cited by 106
Ahmad, N., Lyles, J., Panchal, J., & Deschamps-Braly, J. (2008) · Journal of Craniofacial Surgery · doi:10.1097/scs.0b013e31816ae358 · Cited by 86
Metadata
- Authors
- Pietrzak, W. S., Kumar, M., & Eppley, B. L.
- Affiliations
- Zimmer Biomet (United States) (US)
- Indiana University School of Medicine (US)
- Corresponding author
- Pietrzak, William S.
- Kumar, Mukesh
- Venue
- Journal of Craniofacial Surgery
- Published
- 2003-03
- Volume
- 14
- Issue
- 2
- Pages
- 176-183
- ISSN
- 1049-2275 (ISSN-L)
- OpenAlex
- W2005209581
- Semantic Scholar
- ff19560f65671e160c015658c6c9c7ef08025661
- Cited by
- 44
- References
- 43
- Citations by year
- 2026: 1 · 2024: 1 · 2021: 2 · 2020: 2 · 2019: 2 · 2018: 1 · 2017: 3 · 2016: 2 · 2015: 2 · 2013: 1 · 2012: 5
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Craniofacial Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
- Health Sciences › Medicine › Surgery › Surgical Sutures and Adhesives
- Physical Sciences › Engineering › Biomedical Engineering › Bone Tissue Engineering Materials
- Keywords
- polyglycolic acid, polylactic acid, absorbable polymers, hydrolysis rate, temperature dependence, biodegradation, strength degradation, craniofacial implants
- MeSH terms
- Polylactic Acid-Polyglycolic Acid Copolymer, Animals, Biocompatible Materials, Body Temperature, Calorimetry, Differential Scanning, Hot Temperature, Humans, Hydrolysis, Materials Testing, Polyglycolic Acid, Polymers, Time Factors, Viscosity, Linear Models, Lactic Acid, Absorbable Implants, Models, Animal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.