CoChat

Circadian variation of endothelial cell function, red blood cell deformability and dehydro-thromboxane B2 in healthy volunteers

Bridges, A. B., McLaren, M., Saniabadi, A., Fisher, T. C., Belch, J. J. F. · 1991 · Blood Coagulation & Fibrinolysis
Cited by 41

The DOI matches its Crossref record.

Abstract

There is a circadian variation in the time of onset of thrombotic disorders. The thrombotic tendency of blood is influenced by many factors including complex interactions between endothelial cells, platelets and red blood cells. We studied the circadian variation of various indices of these cells' functions in 10 young healthy male volunteers. Six blood samples were collected at 4 h intervals from 12.00 until 08.00 the following morning. The volunteers carried out normal daily activities until 00.00 at which time they went to bed. They remained in bed until 08.00 the following morning. The following were measured on each sample: plasma factor VIII von Willebrand factor antigen (FVIII vWF Ag), tissue plasminogen activator activity (tPA), plasminogen activator inhibitor (PAI), prostacyclin stimulating factor (PGI2 SF), fibrinopeptide A (FPA), 11 dehydro-thromboxane B2 (11-dehydro-TXB2) and red cell deformability (RCD). The following parameters demonstrated significant circadian variation: tPA P less than 0.001, PAI P less than 0.04 and 11-dehydro-TXB2 P less than 0.005 (two-way analysis of variance). tPA was highest at 16.00-20.00 and lowest at 08.00; PAI was highest at 08.00 and lowest at 20.00; TXB2 had a peak at 16.00 and trough at 04.00. As the behaviour of endothelial cells and platelets influence the rheological properties of blood, circadian variations in their behaviour may contribute to the time of onset of thrombotic disorders.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00001721-199106000-00007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 41

Metadata

Authors
Bridges, A. B., McLaren, M., Saniabadi, A., Fisher, T. C., & Belch, J. J. F.
Venue
Blood Coagulation & Fibrinolysis
Published
1991-06
Volume
2
Issue
3
Pages
447-452
ISSN
0957-5235 (ISSN-L)
OpenAlex
W2005829744
Cited by
41
References
0
FWCI
0.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Circadian variation of endothelial cell function, red blood cell deformability and dehydro-thromboxane B2 in healthy volunteers. https://app.cochat.ai/papers/10.1097/00001721-199106000-00007
The paper
Bridges, A. B., McLaren, M., Saniabadi, A., Fisher, T. C., & Belch, J. J. F. (1991). Circadian variation of endothelial cell function, red blood cell deformability and dehydro-thromboxane B2 in healthy volunteers. Blood Coagulation & Fibrinolysis. https://doi.org/10.1097/00001721-199106000-00007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.