A rapid screen for lupus anticoagulant with good discrimination from oral anticoagulants, congenital factor deficiency and heparin, is provided by comparing a sensitive and an insensitive APTT reagent
The DOI matches its Crossref record.
Abstract
Lupus anticoagulants (LA) are associated with an increased risk of thrombosis and laboratory detection is of major importance. Various tests are available for LA screening and confirmation, but they differ in sensitivity and specificity, frequently lacking the ability to discriminate between the presence of LA, heparin and oral anticoagulants. We noticed that a patient with LA who had a prolonged activated partial thromboplastin time (APTT) by our routine method, gave a normal result with a different APTT reagent. This latter reagent, which contained soy bean phosphatides (SBP), was compared with a reagent containing rabbit brain phospholipids complexed with kaolin (RBK), for APTT measurement in a variety of patients. There was no significant difference in APTT ratio between the two reagents in plasma samples from healthy normal subjects. In LA samples, SBP gave consistently lower APTT ratios than RBK (mean +/- SEM, 1.04 +/- 0.05 and 2.08 +/- 0.19 for SBP and RBK respectively; P < 0.001). In LA patients receiving oral anticoagulants for antithrombotic prophylaxis or treatment, the APTT ratio was again significantly shorter with SBP (1.60 +/- 0.17 and 3.40 +/- 0.67; P < 0.05). In LA negative patients receiving oral anticoagulants, the relationship was reversed, and a higher APTT ratio was obtained with SBP than RBK (1.61 +/- 0.13 and 1.31 +/- 0.12; P < 0.001). In addition, there were no significant differences in APTT ratios for the two reagents when samples from patients receiving heparin therapy, or patients with acquired factor VIII deficiency or inherited deficiency of factor VIII or IX were studied. The use of the SBP reagent alongside a LA sensitive APTT reagent allows a rapid screening for LA, as well as a confirmation of the phospholipid dependency of the inhibitor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines on the investigation and management of antiphospholipid syndrome
Keeling, D., Mackie, I., Moore, G. W., Greer, I. A., Greaves, M., & British Committee for Standards in Haematology (2012) · British Journal of Haematology · doi:10.1111/j.1365-2141.2012.09037.x · Cited by 740
Self-citationGuidelines On The Investigation and Management Of The Antiphospholipid Syndrome
Greaves, M., Cohen, H., Machin, S. J., & Mackie, I. (2000) · British Journal of Haematology · doi:10.1046/j.1365-2141.2000.02069.x · Cited by 294
Self-citationLaboratory Testing for Lupus Anticoagulants: A Review of Issues Affecting Results
Tripodi, A. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.089524 · Cited by 81
Jennings, I., Greaves, M., Mackie, I. J., Kitchen, S., Woods, T. A. L., Preston, F. E., & ation, O. B. O. T. U. N. E. Q. A. S. F. B. C. (2002) · British Journal of Haematology · doi:10.1046/j.1365-2141.2002.03821.x · Cited by 72
“This variable sensitivity has been previously described (Arnout et al, 1999; Jacobsen et al, 2000) and is the basis for the LA screening test approach adopted by some laboratories (Brancaccio et al, 1997).”
BackgroundSelf-citationCiampa, A., Margaglione, M., Scenna, G., Iannaccone, L., Brancaccio, V., & Ames, P. R. J. (2005) · Thrombosis and Haemostasis · doi:10.1160/th04-11-0723 · Cited by 49
Self-citation
Metadata
- Authors
- Brancaccio, V., Ames, P. R. J., Glynn, J., Iannaccone, L., & Mackie, I. J.
- Venue
- Blood Coagulation & Fibrinolysis
- Published
- 1997-04
- Volume
- 8
- Issue
- 3
- Pages
- 155-160
- ISSN
- 0957-5235 (ISSN-L)
- OpenAlex
- W2040003035
- Cited by
- 37
- References
- 0
- FWCI
- 0.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A rapid screen for lupus anticoagulant with good discrimination from oral anticoagulants, congenital factor deficiency and heparin, is provided by comparing a sensitive and an insensitive APTT reagent. https://app.cochat.ai/papers/10.1097/00001721-199704000-00001
- The paper
- Brancaccio, V., Ames, P. R. J., Glynn, J., Iannaccone, L., & Mackie, I. J. (1997). A rapid screen for lupus anticoagulant with good discrimination from oral anticoagulants, congenital factor deficiency and heparin, is provided by comparing a sensitive and an insensitive APTT reagent. Blood Coagulation & Fibrinolysis. https://doi.org/10.1097/00001721-199704000-00001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.