EEG-based control of a hand grasp neuroprosthesis
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The feasibility of using the EEG signal to operate a hand grasp neuroprosthesis was investigated. Two able-bodied subjects and one neuroprosthesis user were trained to control the amplitude of the beta rhythm recorded over the frontal areas. After 6 months, all subjects exhibited a high level of control, being able to use this signal to move a cursor to targets on a computer screen with a high (>90%) accuracy rate. Control over the EEG signal was unaffected by upper extremity movement or electrical activation of the muscles, indicating that this signal would be adequate for neuroprosthetic use. To test this concept, the neuroprosthesis user operated his system with the cortical signal, and was able to effectively manipulate several objects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The cone electrode: Ultrastructural studies following long-term recording in rat and monkey cortex
Kennedy, P. R., Mirra, S. S., & Bakay, R. A. E. (1992) · Neuroscience Letters · doi:10.1016/0304-3940(92)90627-j · Cited by 81
Cited by
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Brain Computer Interfaces, a Review
Nicolas-Alonso, L. F., & Gomez-Gil, J. (2012) · Sensors · doi:10.3390/s120201211 · Cited by 2,143
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862
Self-citationBrain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Functional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 784
Self-citation
Metadata
- Authors
- Lauer, R. T., Peckham, P. H., & Kilgore, K. L.
- Venue
- NeuroReport
- Published
- 1999-06
- Volume
- 10
- Issue
- 8
- Pages
- 1767-1771
- ISSN
- 0959-4965 (ISSN-L)
- OpenAlex
- W2028866098
- Cited by
- 106
- References
- 1
- FWCI
- 3.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: EEG-based control of a hand grasp neuroprosthesis. https://app.cochat.ai/papers/10.1097/00001756-199906030-00026
- The paper
- Lauer, R. T., Peckham, P. H., & Kilgore, K. L. (1999). EEG-based control of a hand grasp neuroprosthesis. NeuroReport. https://doi.org/10.1097/00001756-199906030-00026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.