Comparison between SI and SII responses as a function of stimulus intensity
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
In this MEG study we investigated the differences in responses to somatosensory electrical stimuli between primary (SI) and secondary (SII) sensory cortices using 10 different levels of stimulus intensity, starting from below the sensory threshold up to a weak painful level. SI dipole source linearly increased in amplitude as the stimulus intensity raised up to a strong motor level and then saturated at higher stimulation levels. The contralateral and ipsilateral SII dipole source strengths followed the stimulus intensity growing up to the motor threshold, but showed a decrease at the strong motor level, followed by an increase as the stimulus intensity raised towards the weak painful threshold. These results suggest different responses of SI and SII cortices as the intensity of stimulation rises from non-painful to painful values.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neurophysiological evaluation of pain
Bromm, B., & Lorenz, J. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00075-3 · Cited by 410
Pain-related magnetic fields following painful CO2 laser stimulation in man
Kakigi, R., Koyama, S., Hoshiyama, M., Kitamura, Y., Shimojo, M., & Watanabe, S. (1995) · Neuroscience Letters · doi:10.1016/0304-3940(95)11604-u · Cited by 146
Cited by
Human brain mechanisms of pain perception and regulation in health and disease
Apkarian, A. V., Bushnell, M. C., Treede, R., & Zubieta, J. (2005) · European Journal of Pain · doi:10.1016/j.ejpain.2004.11.001 · Cited by 3,126
A new approach to neuroimaging with magnetoencephalography
Hillebrand, A., Singh, K. D., Holliday, I. E., Furlong, P. L., & Barnes, G. R. (2005) · Human Brain Mapping · doi:10.1002/hbm.20102 · Cited by 549
Brain generators of laser-evoked potentials: from dipoles to functional significance
Garcia-Larrea, L., Frot, M., & Valeriani, M. (2003) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2003.10.008 · Cited by 541
Eickhoff, S. B., Jbabdi, S., Caspers, S., Laird, A. R., Fox, P. T., Zilles, K., & Behrens, T. E. J. (2010) · The Journal of Neuroscience · doi:10.1523/jneurosci.5664-09.2010 · Cited by 352
“Hence, OP 1 may represent the anatomical substrate of the various more complex functions reported to involve the parietal operculum, such as tactile working memory, stimulus discrimination (particularly frequency), and perceptual learning (Romo et al., 2002; Torquati et al., 2002; Pleger et al., 2003; Burton et al., 2…”
BackgroundImaging of central itch modulation in the human brain using positron emission tomography
Mochizuki, H., Tashiro, M., Kano, M., Sakurada, Y., Itoh, M., & Yanai, K. (2003) · Pain · doi:10.1016/s0304-3959(03)00249-5 · Cited by 211
“In the present study, the electrical current given by the iontophoresis was fixed at 1 mA in order to eliminate the possibility that the brain activity changed due to different intensities of the current (Torquati et al., 2002).”
Background
Metadata
- Authors
- Torquati, K., Pizzella, V., Penna, S. D., Franciotti, R., Babiloni, C., Rossini, P. M., & Romani, G. L.
- Venue
- Neuroreport
- Published
- 2002-05
- Volume
- 13
- Issue
- 6
- Pages
- 813-819
- ISSN
- 0959-4965 (ISSN-L)
- OpenAlex
- W2069169400
- Cited by
- 80
- References
- 2
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison between SI and SII responses as a function of stimulus intensity. https://app.cochat.ai/papers/10.1097/00001756-200205070-00016
- The paper
- Torquati, K., Pizzella, V., Penna, S. D., Franciotti, R., Babiloni, C., Rossini, P. M., & Romani, G. L. (2002). Comparison between SI and SII responses as a function of stimulus intensity. Neuroreport. https://doi.org/10.1097/00001756-200205070-00016
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.