Load-Bearing in the Knee Joint
The DOI matches its Crossref record.
Abstract
The surfaces of the knee--anomalous to most animal joints through apparent gross incongruity--would appear more congruous if the menisci bore load. A simple system is used to show how the menisci can bear load. The strong tibial fixation and structure of the menisci, and the geometry of the femoral condyles indicate that the menisci bear load throughout flexion and extension. Confirmatory experimental results show that in partially degenerate human and healthy pigs' knees the menisci bear at least 45 and 75% respectively of the total joint load. The knee joint is similar in this respect to other synovial joints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Makris, E. A., Hadidi, P., & Athanasiou, K. A. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.06.037 · Cited by 1,116
Incidental Meniscal Findings on Knee MRI in Middle-Aged and Elderly Persons
Englund, M., Guermazi, A., Gale, D., Hunter, D. J., Aliabadi, P., Clancy, M., & Felson, D. T. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800777 · Cited by 921
Baratz, M. E., Fu, F. H., & Mengato, R. (1986) · The American Journal of Sports Medicine · doi:10.1177/036354658601400405 · Cited by 830
Computer Modeling and Simulation of Human Movement
Pandy, M. G. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.245 · Cited by 471
Tibiofemoral Contact Mechanics after Serial Medial Meniscectomies in the Human Cadaveric Knee
Lee, S. J., Aadalen, K. J., Malaviya, P., Lorenz, E. P., Hayden, J. K., Farr, J., Kang, R. W., & Cole, B. J. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546506286786 · Cited by 435
MESSNER, K., & GAO, J. (1998) · Journal of Anatomy · doi:10.1046/j.1469-7580.1998.19320161.x · Cited by 431
Importance of the medial meniscus in the anterior cruciate ligament‐deficient knee
Allen, C. R., Wong, E. K., Livesay, G. A., Sakane, M., Fu, F. H., & Woo, S. L. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180116 · Cited by 427
Meniscal movement: AN IN-VIVO STUDY USING DYNAMIC MRI
Vedi, V., Spouse, E., Williams, A., Tennant, S. J., Hunt, D. M., & Gedroyc, W. M. W. (1999) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.81b1.0810037 · Cited by 401
Tibial meniscal dynamics using three-dimensional reconstruction of magnetic resonance images
Thompson, W. O., Thaete, F. L., Fu, F. H., & Dye, S. F. (1991) · The American Journal of Sports Medicine · doi:10.1177/036354659101900302 · Cited by 391
Meniscus pathology, osteoarthritis and the treatment controversy
Englund, M., Roemer, F. W., Hayashi, D., Crema, M. D., & Guermazi, A. (2012) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2012.69 · Cited by 385
Material properties of the normal medial bovine meniscus
Proctor, C. S., Schmidt, M. B., Whipple, R. R., Kelly, M. A., & Mow, V. C. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070602 · Cited by 383
The effect of nanofiber alignment on the maturation of engineered meniscus constructs
Baker, B. M., & Mauck, R. L. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.01.004 · Cited by 379
Anatomy and Biomechanics of the Menisci
Renström, P., & Johnson, R. J. (1990) · Clinics in Sports Medicine · doi:10.1016/s0278-5919(20)30704-3 · Cited by 313
Cooper, D. E., Arnoczky, S. P., & Warren, R. F. (1990) · Clinics in Sports Medicine · doi:10.1016/s0278-5919(20)30710-9 · Cited by 285
The role of the meniscus in knee osteoarthritis: a cause or consequence?
Englund, M., Guermazi, A., & Lohmander, S. L. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2009.03.003 · Cited by 274
Replacement of the rabbit medial meniscus with a polyester-carbon fibre bioprosthesis
Wood, D. J., Minns, R. J., & Strover, A. (1990) · Biomaterials · doi:10.1016/0142-9612(90)90045-r · Cited by 214
The role of biomechanics in the initiation and progression of OA of the knee
Englund, M. (2010) · Best Practice & Research Clinical Rheumatology · doi:10.1016/j.berh.2009.08.008 · Cited by 204
Role of cartilage collagen fibrils networks in knee joint biomechanics under compression
Shirazi, R., Shirazi-Adl, A., & Hurtig, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.09.033 · Cited by 203
“Moreover, predicted values of 50% and 39% for, respectively, lateral and medial menisci at 1400N, though less than measured values of 81% and 77% (Seedhom and Hargreaves, 1979), compared with reported value of 45% averaged over both compartments of 16 specimens under similar loads (Shrive et al., 1978).”
ResultChen, S., Fu, P., Wu, H., & Pei, M. (2017) · Cell and Tissue Research · doi:10.1007/s00441-017-2613-0 · Cited by 199
“Load transmission stems from the wedge shape of the meniscus, on which the hoop stresses from circumferentially oriented collagen fibers balance the shear force from radially oriented collagen fibers when a load is applied (Aspden et al. 1985; Shrive 1974; Shrive et al. 1978); through this mechanism, the meniscus face…”
BackgroundPrinciples and decision making in meniscal surgery
Newman, A. P., Daniels, A. U., & Burks, R. T. (1993) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/s0749-8063(05)80342-1 · Cited by 198
Bendjaballah, M., Shirazi-Adl, A., & Zukor, D. (1995) · The Knee · doi:10.1016/0968-0160(95)00018-k · Cited by 184
Biomechanics of Noncontractile Tissue
Cornwall, M. W. (1984) · Physical Therapy · doi:10.1093/ptj/64.12.1869 · Cited by 30
Metadata
- Authors
- SHRIVE, N. G., O'CONNOR, J. J., & GOODFELLOW, J. W.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1978-03
- Volume
- 131
- Issue
- 131
- Pages
- 279-287
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2039954098
- Cited by
- 355
- References
- 0
- FWCI
- 1.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.