Afferent Sensory Feedback for Lower Extremity Prosthesis
The DOI matches its Crossref record.
Abstract
Electrical stimulation has been applied to sciatic nerves of patients to achieve sensory feedback after lower limb amputation for periods of up to six years. Patients used the sensory feedback device daily. Pain, infection and electrode displacement have not been problems. The immediate postoperative benefits are that pain is minimized after amputation and stump healing is improved. Furthermore, the stimulus affords the patient increased confidence when walking due to renewed awareness of the center of gravity. Improved ability to function in the dark and when walking up and down stairways makes the application of sciatic nerve stimulation after amputation very rewarding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“conveyed information about heel strike and bending moments in lower-limb prostheses [85].”
BackgroundInfluentialSensory feedback for limb prostheses in amputees
Raspopovic, S., Valle, G., & Petrini, F. M. (2021) · Nature Materials · doi:10.1038/s41563-021-00966-9 · Cited by 308
Sensory feedback restoration in leg amputees improves walking speed, metabolic cost and phantom pain
Petrini, F. M., Bumbasirevic, M., Valle, G., Ilic, V., Mijović, P., Čvančara, P., Barberi, F., Katic, N., Bortolotti, D., Andreu, D., et al. (2019) · Nature Medicine · doi:10.1038/s41591-019-0567-3 · Cited by 269
Enhancing functional abilities and cognitive integration of the lower limb prosthesis
Petrini, F. M., Valle, G., Bumbasirevic, M., Barberi, F., Bortolotti, D., Cvancara, P., Hiairrassary, A., Mijovic, P., Sverrisson, A. Ö., Pedrocchi, A., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav8939 · Cited by 265
Restoration of sensory information via bionic hands
Bensmaia, S. J., Tyler, D. J., & Micera, S. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00630-8 · Cited by 257
Metadata
- Authors
- CLIPPINGER, F. W., SEABER, A. V., MCELHANEY, J. H., HARRELSON, J. M., & MAXWELL, G. M.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1982-09
- Volume
- 169
- Issue
- 169
- Pages
- 202-206
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2020673181
- Cited by
- 54
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Afferent Sensory Feedback for Lower Extremity Prosthesis. https://app.cochat.ai/papers/10.1097/00003086-198209000-00031
- The paper
- CLIPPINGER, F. W., SEABER, A. V., MCELHANEY, J. H., HARRELSON, J. M., & MAXWELL, G. M. (1982). Afferent Sensory Feedback for Lower Extremity Prosthesis. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-198209000-00031
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.