Ankle Fractures Treated Using Biodegradable Internal Fixation
Abstract
In order to reduce the resources needed for the removal of metallic fixation devices in fracture treatment, absorbable implants of biodegradable synthetic polymers were developed using self-reinforced lactide-glycolide copolymer and polyglycolide. In a prospective study 102 patients with displaced unimalleolar or bimalleolar fractures of the ankle were managed using internal fixation devices consisting of cylindrical biodegradable implants 3.2 or 4.5 mm in diameter and 50 or 70 mm in length. After open reduction of the fracture a channel was drilled from the tip of the malleolus into the cancellous bone through the fracture surfaces. A biodegradable rod of the same diameter was then tapped into the drill channel to fix the fracture. Postoperatively, the ankle was immobilized by a plaster cast for six weeks. An anatomic initial reduction was achieved in 93 patients (91%). A slight secondary displacement occurred in four patients. In six patients a sinus formation yielding remnants of the degrading implant was seen two to four months after the operation. This minor complication did not influence the union of the fracture or functional recovery. At the one-year follow-up examination there was no change in the ability to participate in sports and other physical activities in 89 patients (87%). The biodegradable fixation method is now the routine approach of the department in treating displaced unimalleolar and bimalleolar ankle fractures. New clinical applications for the implants are under trial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Biocompatibility of hydrogel-based scaffolds for tissue engineering applications
Naahidi, S., Jafari, M., Logan, M., Wang, Y., Yuan, Y., Bae, H., Dixon, B., & Chen, P. (2017) · Biotechnology Advances · doi:10.1016/j.biotechadv.2017.05.006 · Cited by 907
Properties and medical applications of polylactic acid: A review
Hamad, K., Kaseem, M., Yang, H. W., Deri, F., & Ko, Y. G. (2015) · Express Polymer Letters · doi:10.3144/expresspolymlett.2015.42 · Cited by 722
Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review
Böstman, O., & Pihlajamäki, H. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00129-0 · Cited by 509
Self-citationAdverse Tissue Reactions to Bioabsorbable Fixation Devices
B??stman, O. M., & Pihlajam??ki, H. K. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200002000-00026 · Cited by 476
Self-citation
Metadata
- Authors
- BÖSTMAN, O., HIRENSALO, E., VAINIONPÄÄ, S., MÄKELÄ, A., VIHTONEN, K., TÖRMÄLÄ, P., & ROKKANEN, P.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1989-01
- Volume
- 238
- Issue
- 238
- Pages
- 195-203
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2006766724
- Cited by
- 182
- References
- 0
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ankle Fractures Treated Using Biodegradable Internal Fixation. https://app.cochat.ai/papers/10.1097/00003086-198901000-00028
- The paper
- BÖSTMAN, O., HIRENSALO, E., VAINIONPÄÄ, S., MÄKELÄ, A., VIHTONEN, K., TÖRMÄLÄ, P., & ROKKANEN, P. (1989). Ankle Fractures Treated Using Biodegradable Internal Fixation. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-198901000-00028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.