Ankle Fractures Treated Using Biodegradable Internal Fixation
The DOI matches its Crossref record.
Abstract
In order to reduce the resources needed for the removal of metallic fixation devices in fracture treatment, absorbable implants of biodegradable synthetic polymers were developed using self-reinforced lactide-glycolide copolymer and polyglycolide. In a prospective study 102 patients with displaced unimalleolar or bimalleolar fractures of the ankle were managed using internal fixation devices consisting of cylindrical biodegradable implants 3.2 or 4.5 mm in diameter and 50 or 70 mm in length. After open reduction of the fracture a channel was drilled from the tip of the malleolus into the cancellous bone through the fracture surfaces. A biodegradable rod of the same diameter was then tapped into the drill channel to fix the fracture. Postoperatively, the ankle was immobilized by a plaster cast for six weeks. An anatomic initial reduction was achieved in 93 patients (91%). A slight secondary displacement occurred in four patients. In six patients a sinus formation yielding remnants of the degrading implant was seen two to four months after the operation. This minor complication did not influence the union of the fracture or functional recovery. At the one-year follow-up examination there was no change in the ability to participate in sports and other physical activities in 89 patients (87%). The biodegradable fixation method is now the routine approach of the department in treating displaced unimalleolar and bimalleolar ankle fractures. New clinical applications for the implants are under trial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Biocompatibility of hydrogel-based scaffolds for tissue engineering applications
Naahidi, S., Jafari, M., Logan, M., Wang, Y., Yuan, Y., Bae, H., Dixon, B., & Chen, P. (2017) · Biotechnology Advances · doi:10.1016/j.biotechadv.2017.05.006 · Cited by 907
Properties and medical applications of polylactic acid: A review
Hamad, K., Kaseem, M., Yang, H. W., Deri, F., & Ko, Y. G. (2015) · Express Polymer Letters · doi:10.3144/expresspolymlett.2015.42 · Cited by 722
“[92] also reported the biocompatibility of PLA copolymers in the human”
BackgroundClinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review
Böstman, O., & Pihlajamäki, H. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00129-0 · Cited by 509
Self-citationAdverse Tissue Reactions to Bioabsorbable Fixation Devices
B??stman, O. M., & Pihlajam??ki, H. K. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200002000-00026 · Cited by 476
Self-citationPolymer carriers for drug delivery in tissue engineering
Sokolsky-Papkov, M., Agashi, K., Olaye, A., Shakesheff, K., & Domb, A. J. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.04.001 · Cited by 452
Advanced biomaterials for skeletal tissue regeneration: Instructive and smart functions
Barrère, F., Mahmood, T. A., de Groot, K., & van Blitterswijk, C. A. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.12.001 · Cited by 303
Surgical applications of biodegradable polymers in human tissues
Vainionpää, S., Rokkanen, P., & Törmälä, P. (1989) · Progress in Polymer Science · doi:10.1016/0079-6700(89)90013-0 · Cited by 287
Self-citationGrowth factor release from tissue engineering scaffolds
Whitaker, M. J., Quirk, R. A., Howdle, S. M., & Shakesheff, K. M. (2001) · Journal of Pharmacy and Pharmacology · doi:10.1211/0022357011777963 · Cited by 282
Michelson, J. D. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199501000-00020 · Cited by 275
Fixation with bioabsorbable screws for the treatment of fractures of the ankle.
Bucholz, R. W., Henry, S., & Henley, M. B. (1994) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199403000-00001 · Cited by 271
Pre-clinical in vivo evaluation of orthopaedic bioabsorbable devices
An, Y. H., Woolf, S. K., & Friedman, R. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00132-0 · Cited by 224
Bioabsorbable Implants: Review of Clinical Experience in Orthopedic Surgery
Ambrose, C. G., & Clanton, T. O. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000007802.59936.fc · Cited by 220
Integrating novel technologies to fabricate smart scaffolds
Moroni, L., de Wijn, J. R., & van Blitterswijk, C. A. (2008) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856208784089571 · Cited by 216
Furukawa, T., Matsusue, Y., Yasunaga, T., Shikinami, Y., Okuno, M., & Nakamura, T. (2000) · Biomaterials · doi:10.1016/s0142-9612(99)00232-x · Cited by 216
Törmälä, P., Vasenius, J., Vainionpää, S., Laiho, J., Pohjonen, T., & Rokkanen, P. (1991) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820250102 · Cited by 210
Self-citationPolyhydroxyalkanonate derivatives in current clinical applications and trials
Ueda, H., & Tabata, Y. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(03)00037-1 · Cited by 187
Kenley, R., Marden, L., Turek, T., Jin, L., Ron, E., & Hollinger, J. O. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820281004 · Cited by 183
Yildirimer, L., & Seifalian, A. M. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.04.014 · Cited by 98
Metadata
- Authors
- BÖSTMAN, O., HIRENSALO, E., VAINIONPÄÄ, S., MÄKELÄ, A., VIHTONEN, K., TÖRMÄLÄ, P., & ROKKANEN, P.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1989-01
- Volume
- 238
- Issue
- 238
- Pages
- 195-203
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2006766724
- Cited by
- 182
- References
- 0
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.