Interporous Hydroxyapatite as a Bone Graft Substitute in Tibial Plateau Fractures
The DOI matches its Crossref record.
Abstract
The metaphyseal defects in 40 patients with displaced tibial plateau fractures necessitating surgical repair were filled with either cancellous autograft or interporous hydroxyapatite. Roentgenographic and clinical assessments at follow-up periods averaging 15.4 months (autograft) and 34.5 months (hydroxyapatite) demonstrated no significant differences in the two groups. Interporous hydroxyapatite is a safe, effective alternative to autogenous cancellous bone for the filling of metaphyseal defects associated with tibial plateau fractures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Giannoudis, P. V., Dinopoulos, H., & Tsiridis, E. (2005) · Injury · doi:10.1016/j.injury.2005.07.029 · Cited by 2,078
Bioceramics of calcium orthophosphates
Dorozhkin, S. V. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.050 · Cited by 1,338
BONE-GRAFTING AND BONE-GRAFT SUBSTITUTES
FINKEMEIER, C. G. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200203000-00020 · Cited by 1,099
Bone graft and bone graft substitutes: A review of current technology and applications
Damien, C. J., & Parsons, J. R. (1991) · Journal of Applied Biomaterials · doi:10.1002/jab.770020307 · Cited by 1,058
Fernandez de Grado, G., Keller, L., Idoux-Gillet, Y., Wagner, Q., Musset, A.-M., Benkirane-Jessel, N., Bornert, F., & Offner, D. (2018) · Journal of Tissue Engineering · doi:10.1177/2041731418776819 · Cited by 912
Synthetic bone graft substitutes
Moore, W. R., Graves, S. E., & Bain, G. I. (2001) · ANZ Journal of Surgery · doi:10.1046/j.1440-1622.2001.02128.x · Cited by 826
Enhancement of fracture-healing.
Einhorn, T. A. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199506000-00016 · Cited by 772
Alternatives to Autogenous Bone Graft: Efficacy and Indications
Gazdag, A. R., Lane, J. M., Glaser, D., & Forster, R. A. (1995) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-199501000-00001 · Cited by 612
Bone Grafts and Bone Graft Substitutes in Orthopaedic Trauma Surgery: A Critical Analysis
De Long, W. G., Einhorn, T. A., Koval, K., McKee, M., Smith, W., Sanders, R., & Watson, T. (2007) · The Journal of Bone & Joint Surgery · doi:10.2106/jbjs.f.00465 · Cited by 570
Kim, H.-W., Knowles, J. C., & Kim, H.-E. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.07.003 · Cited by 518
Muschler, G. F., Boehm, C., & Easley, K. (1997) · The Journal of Bone and Joint Surgery (American Volume) · doi:10.2106/00004623-199711000-00012 · Cited by 507
The challenge of establishing preclinical models for segmental bone defect research
Reichert, J. C., Saifzadeh, S., Wullschleger, M. E., Epari, D. R., Schütz, M. A., Duda, G. N., Schell, H., van Griensven, M., Redl, H., & Hutmacher, D. W. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.12.050 · Cited by 433
Bone tissue engineering with porous hydroxyapatite ceramics
Yoshikawa, H., & Myoui, A. (2005) · Journal of Artificial Organs · doi:10.1007/s10047-005-0292-1 · Cited by 394
Nonallograft Osteoconductive Bone Graft Substitutes
Bucholz, R. W. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200202000-00006 · Cited by 356
Self-citationLimitations of Autograft and Allograft: New Synthetic Solutions
Betz, R. R. (2002) · Orthopedics · doi:10.3928/0147-7447-20020502-04 · Cited by 335
Bone Repair Techniques, Bone Graft, and Bone Graft Substitutes
Perry, C. R. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199903000-00010 · Cited by 332
Fabrication, Properties and Applications of Dense Hydroxyapatite: A Review
Prakasam, M., Locs, J., Salma-Ancane, K., Loca, D., Largeteau, A., & Berzina-Cimdina, L. (2015) · Journal of Functional Biomaterials · doi:10.3390/jfb6041099 · Cited by 295
Calcium Orthophosphate-Based Bioceramics
Dorozhkin, S. (2013) · Materials · doi:10.3390/ma6093840 · Cited by 295
Comparative performance of three ceramic bone graft substitutes
Hing, K. A., Wilson, L. F., & Buckland, T. (2007) · The Spine Journal · doi:10.1016/j.spinee.2006.07.017 · Cited by 287
Calcium Orthophosphates as Bioceramics: State of the Art
Dorozhkin, S. V. (2010) · Journal of Functional Biomaterials · doi:10.3390/jfb1010022 · Cited by 278
SUBSTITUTES FOR AUTOLOGOUS BONE GRAFT IN ORTHOPAEDIC TRAUMA
Keating, J. F., & McQueen, M. M. (2001) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.83b1.0830003 · Cited by 273
Use of Injectable Calcium Phosphate Cement for Fracture Fixation: A Review
Larsson, S., & Bauer, T. W. (2002) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200202000-00004 · Cited by 257
Yu, P., Bao, R.-Y., Shi, X.-J., Yang, W., & Yang, M.-B. (2017) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2016.09.001 · Cited by 248
den Boer, F. C., Wippermann, B. W., Blokhuis, T. J., Patka, P., Bakker, F. C., & Haarman, H. J. T. M. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(02)00205-x · Cited by 187
Sciadini, M. F., & Johnson, K. D. (2000) · Journal of Orthopaedic Research · doi:10.1002/jor.1100180218 · Cited by 168
Metadata
- Authors
- BUCHOLZ, R. W., CARLTON, A., & HOLMES, R.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1989-03
- Volume
- 240
- Issue
- 240
- Pages
- 53-62
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2055360130
- Cited by
- 333
- References
- 0
- FWCI
- 3.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.