The DOI matches its Crossref record.
A Clinical-Pathologic-Biochemical Study of the Membrane Surrounding Loosened and Nonloosened Total Hip Arthroplasties
Abstract
The clinical and roentgenologic data from 31 excised components from 19 revision arthroplasty cases were correlated with the histology and biochemistry of the membrane at the bone-cement or bone-prosthesis interface. Twenty-seven components were cemented and four were uncemented. Twenty-four implants were clinically and roentgenologically loose, one was possibly loose, and six were well fixed. Loose components, whether cemented or not, demonstrated statistically higher prostaglandin E2 levels in the surrounding membrane compared to the nonloose group. Collagenase and M-collagenase levels were absent or insignificantly low in all specimens; no detectable interleukin 1 beta was found. This suggests that prostaglandin E2 may be associated with the bone lysis associated with prosthesis loosening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of macrophages in osteolysis of total joint replacement
Ingham, E., & Fisher, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.035 · Cited by 667
Jiranek, W. A., Machado, M., Jasty, M., Jevsevar, D., Wolfe, H. J., Goldring, S. R., Goldberg, M. J., & Harris, W. H. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199306000-00007 · Cited by 436
Macrophage/particle interactions: Effect of size, composition and surface area
Shanbhag, A. S., Jacobs, J. J., Black, J., Galante, J. O., & Glant, T. T. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280111 · Cited by 410
A review of investigations on biocompatibility of diamond-like carbon and carbon nitride films
Cui, F. Z., & Li, D. J. (2000) · Surface and Coatings Technology · doi:10.1016/s0257-8972(00)00809-4 · Cited by 365
Isolation of predominantly submicron‐sized UHMWPE wear particles from periprosthetic tissues
Campbell, P., Ma, S., Yeom, B., McKellop, H., Schmalzried, T. P., & Amstutz, H. C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290118 · Cited by 352
Metadata
- Authors
- GOODMAN, S. B., CHIN, R. C., CHIOU, S. S., SCHURMAN, D. J., WOOLSON, S. T., & MASADA, M. P.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1989-07
- Volume
- 244
- Issue
- 244
- Pages
- 182-187
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1994433959
- Cited by
- 168
- References
- 0
- FWCI
- 4.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Clinical-Pathologic-Biochemical Study of the Membrane Surrounding Loosened and Nonloosened Total Hip Arthroplasties. https://app.cochat.ai/papers/10.1097/00003086-198907000-00017
- The paper
- GOODMAN, S. B., CHIN, R. C., CHIOU, S. S., SCHURMAN, D. J., WOOLSON, S. T., & MASADA, M. P. (1989). A Clinical-Pathologic-Biochemical Study of the Membrane Surrounding Loosened and Nonloosened Total Hip Arthroplasties. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-198907000-00017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.