Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 777

The DOI matches its Crossref record.

Material Properties and Structure-Function Relationships in the Menisci

FITHIAN, DONALD C., KELLY, MICHAEL A., MOW, VAN C.·1990·Clinical Orthopaedics and Related Research

Abstract

The menisci serve several important biomechanical functions in the knee. They distribute stresses over a broad area of articular cartilage, absorb shocks during dynamic loading, and probably assist in joint lubrication. These functions enhance the ability of articular cartilage to provide a smooth, near-frictionless articulation and to distribute loads evenly to the underlying bone of the femur and tibia. In addition, the menisci provide stability to the injured knee when the cruciate ligaments or other primary stabilizers are deficient. The ability to perform these mechanical functions is based on the intrinsic material properties of the menisci as well as their gross anatomic structure and attachments. The material properties of the menisci are determined by their biochemical composition and, perhaps more important, by the organization and interactions of the major tissue constituents: water, proteoglycan, and collagen. Interactions among the important constituents of the fibrocartilage matrix cause meniscal tissue to behave as a fiber-reinforced, porous, permeable composite material similar to articular cartilage, in which frictional drag caused by fluid flow governs its response to dynamic loading. The menisci are one-half as stiff in compression and dissipate more energy under dynamic loading than articular cartilage. Energy dissipation, or shock absorption, by the menisci is the result of high frictional drag caused by low permeability of the matrix, which is about one-sixth as permeable as articular cartilage. The dynamic shear modulus of meniscal tissue is only one-fourth to one-sixth as great as that of articular cartilage. The coarse, circumferential Type I collagen fiber bundles of the meniscus give the tissue great tensile stiffness (range, 100-300 megapascals) and strength. The highly oriented collagen ultrastructure of the menisci makes the tissue anisotropic in tension, compression, and shear and appears to dominate its behavior under all loading conditions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00003086-199003000-00004

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 777

Metadata

Authors
FITHIAN, D. C., KELLY, M. A., & MOW, V. C.
Venue
Clinical Orthopaedics and Related Research
Published
1990-03
Volume
252
Issue
252
Pages
19-31
ISSN
0009-921X (ISSN-L)
OpenAlex
W2082510662
Cited by
777
References
0
FWCI
3.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Material Properties and Structure-Function Relationships in the Menisci. https://app.cochat.ai/papers/10.1097/00003086-199003000-00004
The paper
FITHIAN, D. C., KELLY, M. A., & MOW, V. C. (1990). Material Properties and Structure-Function Relationships in the Menisci. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199003000-00004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.