The DOI matches its Crossref record.
A Correlative Study of the Geometry and Anatomy of the Distal Femur
Abstract
Sixteen knees were examined roentgenographically in the lateral plane. Ten knees were examined from autopsy subjects. The distal articular femur may be represented by three circular surfaces: (1) the floor of the patellar groove (articulating with the patella from 10 degrees to 100 degrees), (2) the posterior femoral condyles (articulating with the tibia from 10 degrees to 150 degrees), and (3) the distal condyles (articulating with the tibia from 0 degrees to 10 degrees). The radii of these surfaces, their angular arcs, and the distances between their centers varied with the size of the femur but fell within a narrow range. The radii of the patellar groove and the posterior femoral condyles averaged 24 mm and 21 mm, and the average angle subtended by these arcs was 90 degrees and 140 degrees, respectively. The average distance between the centers of these two circles was 20 mm. The femoral attachment of the synovial and patellar retinacular reflections was found in the area of the center of the patellar groove circle. The femoral attachments of the medial collateral and posterior cruciate ligaments and of the lateral collateral and anterior cruciate ligaments were found to be in the area of the center of the circle of the medial and lateral posterior femoral condylar circles, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The movement of the normal tibio-femoral joint
Freeman, M. A. R., & Pinskerova, V. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.006 · Cited by 532
Self-citationThe Transepicondylar Axis Approximates the Optimal Flexion Axis of the Knee
Churchill, D. L., Incavo, S. J., Johnson, C. C., & Beynnon, B. D. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199811000-00016 · Cited by 497
Johal, P., Williams, A., Wragg, P., Hunt, D., & Gedroyc, W. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.008 · Cited by 360
THREE-DIMENSIONAL MECHANICS, KINEMATICS, AND MORPHOLOGY OF THE KNEE VIEWED IN VIRTUAL REALITY
ECKHOFF, D. G., BACH, J. M., SPITZER, V. M., REINIG, K. D., BAGUR, M. M., BALDINI, T. H., & FLANNERY, N. M. P. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200511002-00009 · Cited by 293
Isometric Reconstruction of the Anterior Cruciate Ligament: Femoral and Tibial Tunnel Placement
Laboureau, J. P., & Marnat-Perrichet, F. (1997) · Ligaments and Ligamentoplasties · doi:10.1007/978-3-642-60428-7_10 · Cited by 8
Metadata
- Authors
- ELIAS, S. G., FREEMAN, M. A. R., & GOKCAY, E. I.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1990-11
- Volume
- 260
- Issue
- 260
- Pages
- 98-103
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W1967083861
- Cited by
- 173
- References
- 0
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Correlative Study of the Geometry and Anatomy of the Distal Femur. https://app.cochat.ai/papers/10.1097/00003086-199011000-00018
- The paper
- ELIAS, S. G., FREEMAN, M. A. R., & GOKCAY, E. I. (1990). A Correlative Study of the Geometry and Anatomy of the Distal Femur. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199011000-00018
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.