Mechanical Properties of Peripheral Nerves
The DOI matches its Crossref record.
Abstract
Peripheral nerve trunks are viscoelastic tissues with unique mechanical characteristics. Tensile strength, which includes elastic limit and mechanical failure, concerns surgeons. This study shows that measurements of the load necessary to achieve certain elongations on specimens outside the body do not correspond with in situ measurements. The necessary load is influenced by the presence or absence of branches and by the amount of fibrosis. Because of transverse contraction, elongation beyond a certain limit substantially decreases intrafascicular volume, leading to increased intrafascicular pressure. Stress relaxation is effective only if the nerve repair site is maintained under constant tension. Its beneficial effect disappears after 10 minutes if the repaired nerve is returned to a relaxed state. Therefore, tension at the repair site should be minimized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gu, X., Ding, F., Yang, Y., & Liu, J. (2011) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.11.002 · Cited by 583
Coppieters, M. W., & Butler, D. S. (2008) · Manual Therapy · doi:10.1016/j.math.2006.12.008 · Cited by 385
Topp, K. S., & Boyd, B. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.1.92 · Cited by 361
Injectable hydrogels for central nervous system therapy
Pakulska, M. M., Ballios, B. G., & Shoichet, M. S. (2012) · Biomedical Materials · doi:10.1088/1748-6041/7/2/024101 · Cited by 216
“at this location [106, 107].”
Biodegradable polyester elastomers in tissue engineering
Webb, A. R., Yang, J., & Ameer, G. A. (2004) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.4.6.801 · Cited by 208
Guo, B., Chen, Y., Lei, Y., Zhang, L., Zhou, W. Y., Rabie, A. B. M., & Zhao, J. (2011) · Biomacromolecules · doi:10.1021/bm2000378 · Cited by 189
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Recruitment characteristics of nerve fascicles stimulated by a multigroove electrode
Koole, P., Holsheimer, J., Struijk, J. J., & Verloop, A. J. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559348 · Cited by 56
A handheld device for magnetically inserting a neural interface into a peripheral nervous system
Yim, S., Hwang, D., Ihn, Y. S., Jeong, J., Oh, S.-R., & Kim, K. (2017) · 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036803 · Cited by 5
“However, the PNS is very slippery, frail and flexible, and covered with tough membranes [13].”
BackgroundPreliminary results of a handheld nerve electrode insertion device
Yim, S., Oh, Y.-E., Choi, W., Park, H., Jeong, J., Ihn, Y., Hwang, D., Oh, S.-R., Kim, J., & Kim, K. (2018) · 2018 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2018.8460882 · Cited by 4
Metadata
- Authors
- Millesi, H., Zöch, G., & Reihsner, R.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1995-05
- Volume
- 314
- Issue
- 314
- Pages
- 76-83
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2024901299
- Cited by
- 198
- References
- 0
- FWCI
- 1.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.