A handheld device for magnetically inserting a neural interface into a peripheral nervous system
Abstract
This paper proposes a compact handheld device for magnetically inserting a neural interface into a peripheral nervous system (PNS). Users can pull and hold a flexible peripheral nerve (e.g., sciatic nerve) at the front of the device for the accurate and stable targeting process. The device automatically inserts a neural interface using magnetic impacts that are generated by a miniature motor and a pair of magnets. We investigate the characteristics of the employed mechanism, and present the preliminary experimental results.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Pneumatic/high-speed inserters have been designed to break through the tough barriers of the perineurium.
“Pneumatic/high-speed inserters have been designed to break through the tough barriers of the perineurium [57, 58].”
From Directed stimulation with interfascicular interfaces for peripheral nerve stimulation (2021) · cites this paper as [57]
Cites
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082 · see citing works
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001 · see citing works
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751 · cited 1× · see citing works
“Neuroprosthetic devices have been studied for many years as a new method to restore motor functions in paralyzed limbs [1-3] and/or to interconnect amputee with robotic limbs [4-5].”
MethodA transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 470 · cited 1× · see citing works
“Longitudinal intra-fascicular electrode (LIFE) [6-7], transverse intrafascicular multichannel electrode (TIME) [8-9], microelectrode arrays (MEAs) [10-12], etc.”
BackgroundDesign and Rolling Locomotion of a Magnetically Actuated Soft Capsule Endoscope
Yim, S., & Sitti, M. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2163861 · Cited by 405 · see citing works
Self-citationSingle unit recording capabilities of a 100 microelectrode array
Nordhausen, C. T., Maynard, E. M., & Normann, R. A. (1996) · Brain Research · doi:10.1016/0006-8993(96)00321-6 · Cited by 358 · see citing works
A method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 305 · see citing works
Long-term stimulation and recording with a penetrating microelectrode array in cat sciatic nerve
Branner, A., Stein, R. B., Fernandez, E., Aoyagi, Y., & Normann, R. A. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.820321 · Cited by 301 · see citing works
A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of cats
Branner, A., & Normann, R. A. (2000) · Brain Research Bulletin · doi:10.1016/s0361-9230(99)00231-2 · Cited by 234 · see citing works
Mechanical Properties of Peripheral Nerves
Millesi, H., Zöch, G., & Reihsner, R. (1995) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199505000-00011 · Cited by 198 · see citing works
Bionic prosthetic hands: A review of present technology and future aspirations
Clement, R. G. E., Bugler, K. E., & Oliver, C. (2011) · The Surgeon · doi:10.1016/j.surge.2011.06.001 · Cited by 190 · see citing works
Rousche, P. J., & Normann, R. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750552 · Cited by 187 · see citing works
Shape-Programmable Soft Capsule Robots for Semi-Implantable Drug Delivery
Yim, S., & Sitti, M. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2197309 · Cited by 133 · see citing works
Self-citationAn intrafascicular electrode for recording of action potentials in peripheral nerves
Malagodi, M. S., Horch, K. W., & Schoenberg, A. A. (1989) · Annals of Biomedical Engineering · doi:10.1007/bf02368058 · Cited by 107 · see citing works
Lawrence, S. M., Dhillon, G. S., Jensen, W., Yoshida, K., & Horch, K. W. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.831491 · Cited by 106 · cited 1× · see citing works
“Longitudinal intra-fascicular electrode (LIFE) [6-7], transverse intrafascicular multichannel electrode (TIME) [8-9], microelectrode arrays (MEAs) [10-12], etc.”
BackgroundBiological and bionic hands: natural neural coding and artificial perception
Bensmaia, S. J. (2015) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2014.0209 · Cited by 67 · see citing works
Magnetic mechanical capsule robot for multiple locomotion mechanisms
Yim, S., & Jeon, D. (2014) · International Journal of Control Automation and Systems · doi:10.1007/s12555-013-0078-9 · Cited by 15 · see citing works
Self-citationJeong, J., Jung, W., Kim, O., Chu, J.-U., Youn, I., Kim, K., Oh, S. R., Park, J. W., & Kim, J. (2016) · 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523786 · Cited by 14 · see citing works
Self-citationHwang, D., Ihn, Y. S., Hwang, S., Oh, S., & Kim, K. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523685 · Cited by 3 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Directed stimulation with interfascicular interfaces for peripheral nerve stimulation
Koppaka, S., Hess-Dunning, A., & Tyler, D. J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac33e8 · Cited by 7 · see citing works
“Pneumatic/high-speed inserters have been designed to break through the tough barriers of the perineurium [57, 58].”
BackgroundPreliminary results of a handheld nerve electrode insertion device
Yim, S., Oh, Y.-E., Choi, W., Park, H., Jeong, J., Ihn, Y., Hwang, D., Oh, S.-R., Kim, J., & Kim, K. (2018) · 2018 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2018.8460882 · Cited by 4 · see citing works
- Authors
- Yim, S., Hwang, D., Ihn, Y. S., Jeong, J., Oh, S.-R., & Kim, K.
- Affiliations
- Korea Institute of Science and Technology (KR)
- Sungkyunkwan University (KR)
- Korean Association Of Science and Technology Studies (KR)
- Venue
- 2017 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2017-07
- Volume
- 28
- Pages
- 226-229
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W2755769989
- Cited by
- 5
- References
- 19
- Citations by year
- 2022: 1 · 2021: 1 · 2020: 1 · 2018: 2
- FWCI
- 3.21
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Open Access System for Information Sharing (Pohang University of Science and Technology) (submittedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- neural interfaces, peripheral nerve stimulation, handheld devices, sciatic nerve, peripheral nervous system, magnetic actuators, miniature motor, biomedical implants
- MeSH terms
- Peripheral Nervous System
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review