The DOI matches its Crossref record.
Measurement of Polyethylene Wear in Metal-Backed Acetabular Cups: I. Three-Dimensional Technique
Abstract
A new technique, the 3-dimensional technique, has been developed. Using a digitzer, points taken from anteroposterior and lateral radiographs are input into a personal computer. A 3-dimensional solid model of the prosthesis is created using custom software. Tilt and anteversion of the acetabular cup are measured, and the model is rotated to a standard frontal view, allowing measurement of femoral head displacement from the center of the acetabular cup. Comparing serial radiographs of the same patient gives the direction and distance of femoral head displacement over time, and this value is used to calculate the minimum volume of polyethylene debris generated. The 3-dimensional technique has been validated by construction of a precision acrylic phantom, and milling of a metal-backed acetabular cup to simulate polyethylene wear. Three-dimensional measurement of femoral head displacement using this technique has an accuracy of +/- 0.15 mm, and volume calculations are within 8% of the true amount of polyethylene removed from the cup. The 3-dimensional technique gives previously unavailable information, and can be used for clinical evaluation of polyethylene wear and evaluation of new prosthetic designs and bearing surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Emergence of Nanoplastic in the Environment and Possible Impact on Human Health
Lehner, R., Weder, C., Petri-Fink, A., & Rothen-Rutishauser, B. (2019) · Environmental Science & Technology · doi:10.1021/acs.est.8b05512 · Cited by 1,242
Current Concepts Review - Wear in Total Hip and Knee Replacements*
SCHMALZRIED, T. P., & CALLAGHAN, J. J. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199901000-00016 · Cited by 395
Determination of Polyethylene Wear in Total Hip Replacements with Use of Digital Radiographs*
Martell, J. M., & Berdia, S. (1997) · The Journal of Bone and Joint Surgery (American Volume) · doi:10.2106/00004623-199711000-00004 · Cited by 321
Metadata
- Authors
- Devane, P. A., Bourne, R. B., Rorabeck, C. H., Hardie, R. M., & Home, J. G.
- Venue
- Clinical Orthopaedics and Related Research
- Published
- 1995-10
- Volume
- 319
- Issue
- 319
- Pages
- 303-316
- ISSN
- 0009-921X (ISSN-L)
- OpenAlex
- W2000792157
- Cited by
- 185
- References
- 0
- FWCI
- 7.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of Polyethylene Wear in Metal-Backed Acetabular Cups: I. Three-Dimensional Technique. https://app.cochat.ai/papers/10.1097/00003086-199510000-00033
- The paper
- Devane, P. A., Bourne, R. B., Rorabeck, C. H., Hardie, R. M., & Home, J. G. (1995). Measurement of Polyethylene Wear in Metal-Backed Acetabular Cups: I. Three-Dimensional Technique. Clinical Orthopaedics and Related Research. https://doi.org/10.1097/00003086-199510000-00033
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.