Determination of Polyethylene Wear in Total Hip Replacements with Use of Digital Radiographs*

Martell, John M., Berdia, Sunjay·1997·The Journal of Bone and Joint Surgery (American Volume)

Abstract

UNLABELLED: We describe a computer-assisted vector wear technique for the determination of polyethylene wear on digital radiographs. Twenty-five hips that had had a total hip arthroplasty were used to evaluate the repeatability and performance of three radiographic techniques to measure wear of the acetabular polyethylene liner: the manual technique with use of calipers described by Livermore et al., the same technique with use of a digitizing tablet, and our new technique of computer-assisted vector wear analysis. We found our new technique to be at least ten times more repeatable than the technique with use of either calipers or a digitizing tablet. Fourteen of the polyethylene liners were retrieved at autopsy, and the actual measurements of wear of those liners were compared with the measurements that had been obtained with the three radiographic techniques of wear analysis. Computer-assisted vector wear analysis outperformed the manual techniques of Livermore et al. When compared with the data obtained from the specimens retrieved at autopsy, the measurement of wear determined with the computer-assisted technique differed by an average of 0.08 millimeter, whereas the measurements obtained with use of calipers and use of a digitizing tablet differed by 0.26 and 0.25 millimeter, respectively. The performance of computer-assisted vector wear analysis in the clinical setting was evaluated with use of controls with known amounts of wear. These were mounted in pelvic phantoms, and radiographs were made with use of a setup that simulated the clinical setting. Analysis of nine controls with 2.0 millimeters of wear yielded an average measurement of wear (and a standard deviation) of 1.99 +/- 0.21 millimeters. CLINICAL RELEVANCE: Computer-assisted vector wear analysis demonstrated superior repeatability and accuracy compared with current techniques of manual analysis. Improved repeatability and accuracy in the determination of polyethylene wear should facilitate the investigation of factors related to the prosthesis and to the patient that affect the rates of wear.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-199711000-00004

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 321

Metadata

Authors
Martell, J. M., & Berdia, S.
Venue
The Journal of Bone and Joint Surgery (American Volume)
Published
1997-11
Volume
79
Issue
11
Pages
1635-1641
ISSN
0021-9355 (ISSN-L)
OpenAlex
W1932541972
Cited by
321
References
6
FWCI
3.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determination of Polyethylene Wear in Total Hip Replacements with Use of Digital Radiographs*. https://app.cochat.ai/papers/10.2106/00004623-199711000-00004
The paper
Martell, J. M., & Berdia, S. (1997). Determination of Polyethylene Wear in Total Hip Replacements with Use of Digital Radiographs*. The Journal of Bone and Joint Surgery (American Volume). https://doi.org/10.2106/00004623-199711000-00004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.